DEVELOPMENT OF HEATED STREAM ABOVE THE HORIZONTAL SURFACE

The development of thermal contaminated air stream formed above the surface of lengthy heated plate is investigated on the basis of the mathematical model of heat and mass transfer processes. The numerical simulation results performed for the purpose of finding a way to prevent the contaminants outf...

Full description

Saved in:
Bibliographic Details
Main Authors: P. I. Diachek, A. E. Zakharevich, I. Yu. Hrachou
Format: Article
Language:Russian
Published: Belarusian National Technical University 2014-12-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/812
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832557278107009024
author P. I. Diachek
A. E. Zakharevich
I. Yu. Hrachou
author_facet P. I. Diachek
A. E. Zakharevich
I. Yu. Hrachou
author_sort P. I. Diachek
collection DOAJ
description The development of thermal contaminated air stream formed above the surface of lengthy heated plate is investigated on the basis of the mathematical model of heat and mass transfer processes. The numerical simulation results performed for the purpose of finding a way to prevent the contaminants outflow from the hood in the presence of external influence are given. Three variants of the hood side panels lengthening are considered: on either side; on the side of the fresh air supply; on the side opposite to the location of air distributors. Comparison of the effects of using these variants of hood design allowed determining that the hood panel located on the side of the coming air flow gives the greatest leakage reduction. It is found out that lengthening of the hood side panels does not ensure full localization of the contaminated convective stream.Several variants of using the screen located on the side of the lateral air flow were investigated in the course of work. Best result is observed under conditions of application of the screen symmetrically located relative to spacing between the hood and the plate. The analysis of local values of temperature and velocity fields in this case shows that losses of heated contaminated air to the workshop space are practically absent. It is found out that the convective stream can be most efficiently localized under the condition of hood-symmetric distribution of supply air. Influence of the open gate on convective stream formation in the workshop space with heat emission is considered. The shift of upward flow to the opposite side relative to the gate is observed. The radiant heat release from the board is of great importance in the temperature field formation of closely located areas of floor and walls surfaces
format Article
id doaj-art-fe43d2068da34cf18fd2b3c839c6a606
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2014-12-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-fe43d2068da34cf18fd2b3c839c6a6062025-02-03T05:35:41ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412014-12-01067382804DEVELOPMENT OF HEATED STREAM ABOVE THE HORIZONTAL SURFACEP. I. Diachek0A. E. Zakharevich1I. Yu. Hrachou2Белорусский национальный технический университетБелорусский национальный технический университетBelarusian National Technical UniversityThe development of thermal contaminated air stream formed above the surface of lengthy heated plate is investigated on the basis of the mathematical model of heat and mass transfer processes. The numerical simulation results performed for the purpose of finding a way to prevent the contaminants outflow from the hood in the presence of external influence are given. Three variants of the hood side panels lengthening are considered: on either side; on the side of the fresh air supply; on the side opposite to the location of air distributors. Comparison of the effects of using these variants of hood design allowed determining that the hood panel located on the side of the coming air flow gives the greatest leakage reduction. It is found out that lengthening of the hood side panels does not ensure full localization of the contaminated convective stream.Several variants of using the screen located on the side of the lateral air flow were investigated in the course of work. Best result is observed under conditions of application of the screen symmetrically located relative to spacing between the hood and the plate. The analysis of local values of temperature and velocity fields in this case shows that losses of heated contaminated air to the workshop space are practically absent. It is found out that the convective stream can be most efficiently localized under the condition of hood-symmetric distribution of supply air. Influence of the open gate on convective stream formation in the workshop space with heat emission is considered. The shift of upward flow to the opposite side relative to the gate is observed. The radiant heat release from the board is of great importance in the temperature field formation of closely located areas of floor and walls surfaceshttps://energy.bntu.by/jour/article/view/812numerical simulationmechanical ventilationhoodconvective streamtemperature fieldvelocity field
spellingShingle P. I. Diachek
A. E. Zakharevich
I. Yu. Hrachou
DEVELOPMENT OF HEATED STREAM ABOVE THE HORIZONTAL SURFACE
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
numerical simulation
mechanical ventilation
hood
convective stream
temperature field
velocity field
title DEVELOPMENT OF HEATED STREAM ABOVE THE HORIZONTAL SURFACE
title_full DEVELOPMENT OF HEATED STREAM ABOVE THE HORIZONTAL SURFACE
title_fullStr DEVELOPMENT OF HEATED STREAM ABOVE THE HORIZONTAL SURFACE
title_full_unstemmed DEVELOPMENT OF HEATED STREAM ABOVE THE HORIZONTAL SURFACE
title_short DEVELOPMENT OF HEATED STREAM ABOVE THE HORIZONTAL SURFACE
title_sort development of heated stream above the horizontal surface
topic numerical simulation
mechanical ventilation
hood
convective stream
temperature field
velocity field
url https://energy.bntu.by/jour/article/view/812
work_keys_str_mv AT pidiachek developmentofheatedstreamabovethehorizontalsurface
AT aezakharevich developmentofheatedstreamabovethehorizontalsurface
AT iyuhrachou developmentofheatedstreamabovethehorizontalsurface