Effect of Ambient Temperature on Performance of Grid-Connected Inverter Installed in Thailand

The effects of temperature on performance of a grid-connected inverter, and also on a photovoltaic (PV) system installed in Thailand have been investigated. It was found that the maximum efficiency of the inverter showed 2.5% drop when ambient temperature was above 37°C. The inverter performed effic...

Full description

Saved in:
Bibliographic Details
Main Authors: Kamonpan Chumpolrat, Vichit Sangsuwan, Nuttakarn Udomdachanut, Songkiate Kittisontirak, Sasiwimon Songtrai, Perawut Chinnavornrungsee, Amornrat Limmanee, Jaran Sritharathikhun, Kobsak Sriprapha
Format: Article
Language:English
Published: Wiley 2014-01-01
Series:International Journal of Photoenergy
Online Access:http://dx.doi.org/10.1155/2014/502628
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832554744650924032
author Kamonpan Chumpolrat
Vichit Sangsuwan
Nuttakarn Udomdachanut
Songkiate Kittisontirak
Sasiwimon Songtrai
Perawut Chinnavornrungsee
Amornrat Limmanee
Jaran Sritharathikhun
Kobsak Sriprapha
author_facet Kamonpan Chumpolrat
Vichit Sangsuwan
Nuttakarn Udomdachanut
Songkiate Kittisontirak
Sasiwimon Songtrai
Perawut Chinnavornrungsee
Amornrat Limmanee
Jaran Sritharathikhun
Kobsak Sriprapha
author_sort Kamonpan Chumpolrat
collection DOAJ
description The effects of temperature on performance of a grid-connected inverter, and also on a photovoltaic (PV) system installed in Thailand have been investigated. It was found that the maximum efficiency of the inverter showed 2.5% drop when ambient temperature was above 37°C. The inverter performed efficiently in November and December, the months of high irradiance, and monthly average ambient temperature of lower than 35°C, allowing relatively high system performance ratio in this period. Our results show that high temperature provides negative impacts not only on the PV modules, but also on the performance of the inverter. Thus, the effect of temperature on the inverter efficiency should be taken into account when predicting energy yield or analyzing losses of the PV systems—especially in high temperature regions.
format Article
id doaj-art-fdc181bb98c249d69f60727bbedfe0ef
institution Kabale University
issn 1110-662X
1687-529X
language English
publishDate 2014-01-01
publisher Wiley
record_format Article
series International Journal of Photoenergy
spelling doaj-art-fdc181bb98c249d69f60727bbedfe0ef2025-02-03T05:50:42ZengWileyInternational Journal of Photoenergy1110-662X1687-529X2014-01-01201410.1155/2014/502628502628Effect of Ambient Temperature on Performance of Grid-Connected Inverter Installed in ThailandKamonpan Chumpolrat0Vichit Sangsuwan1Nuttakarn Udomdachanut2Songkiate Kittisontirak3Sasiwimon Songtrai4Perawut Chinnavornrungsee5Amornrat Limmanee6Jaran Sritharathikhun7Kobsak Sriprapha8National Electronics and Computer Technology Center, 112 Thailand Science Park, Phahonyotin Road, Klong 1, Klong Luang, Pathumthani 12120, ThailandNational Electronics and Computer Technology Center, 112 Thailand Science Park, Phahonyotin Road, Klong 1, Klong Luang, Pathumthani 12120, ThailandNational Electronics and Computer Technology Center, 112 Thailand Science Park, Phahonyotin Road, Klong 1, Klong Luang, Pathumthani 12120, ThailandNational Electronics and Computer Technology Center, 112 Thailand Science Park, Phahonyotin Road, Klong 1, Klong Luang, Pathumthani 12120, ThailandNational Electronics and Computer Technology Center, 112 Thailand Science Park, Phahonyotin Road, Klong 1, Klong Luang, Pathumthani 12120, ThailandNational Electronics and Computer Technology Center, 112 Thailand Science Park, Phahonyotin Road, Klong 1, Klong Luang, Pathumthani 12120, ThailandNational Electronics and Computer Technology Center, 112 Thailand Science Park, Phahonyotin Road, Klong 1, Klong Luang, Pathumthani 12120, ThailandNational Electronics and Computer Technology Center, 112 Thailand Science Park, Phahonyotin Road, Klong 1, Klong Luang, Pathumthani 12120, ThailandNational Electronics and Computer Technology Center, 112 Thailand Science Park, Phahonyotin Road, Klong 1, Klong Luang, Pathumthani 12120, ThailandThe effects of temperature on performance of a grid-connected inverter, and also on a photovoltaic (PV) system installed in Thailand have been investigated. It was found that the maximum efficiency of the inverter showed 2.5% drop when ambient temperature was above 37°C. The inverter performed efficiently in November and December, the months of high irradiance, and monthly average ambient temperature of lower than 35°C, allowing relatively high system performance ratio in this period. Our results show that high temperature provides negative impacts not only on the PV modules, but also on the performance of the inverter. Thus, the effect of temperature on the inverter efficiency should be taken into account when predicting energy yield or analyzing losses of the PV systems—especially in high temperature regions.http://dx.doi.org/10.1155/2014/502628
spellingShingle Kamonpan Chumpolrat
Vichit Sangsuwan
Nuttakarn Udomdachanut
Songkiate Kittisontirak
Sasiwimon Songtrai
Perawut Chinnavornrungsee
Amornrat Limmanee
Jaran Sritharathikhun
Kobsak Sriprapha
Effect of Ambient Temperature on Performance of Grid-Connected Inverter Installed in Thailand
International Journal of Photoenergy
title Effect of Ambient Temperature on Performance of Grid-Connected Inverter Installed in Thailand
title_full Effect of Ambient Temperature on Performance of Grid-Connected Inverter Installed in Thailand
title_fullStr Effect of Ambient Temperature on Performance of Grid-Connected Inverter Installed in Thailand
title_full_unstemmed Effect of Ambient Temperature on Performance of Grid-Connected Inverter Installed in Thailand
title_short Effect of Ambient Temperature on Performance of Grid-Connected Inverter Installed in Thailand
title_sort effect of ambient temperature on performance of grid connected inverter installed in thailand
url http://dx.doi.org/10.1155/2014/502628
work_keys_str_mv AT kamonpanchumpolrat effectofambienttemperatureonperformanceofgridconnectedinverterinstalledinthailand
AT vichitsangsuwan effectofambienttemperatureonperformanceofgridconnectedinverterinstalledinthailand
AT nuttakarnudomdachanut effectofambienttemperatureonperformanceofgridconnectedinverterinstalledinthailand
AT songkiatekittisontirak effectofambienttemperatureonperformanceofgridconnectedinverterinstalledinthailand
AT sasiwimonsongtrai effectofambienttemperatureonperformanceofgridconnectedinverterinstalledinthailand
AT perawutchinnavornrungsee effectofambienttemperatureonperformanceofgridconnectedinverterinstalledinthailand
AT amornratlimmanee effectofambienttemperatureonperformanceofgridconnectedinverterinstalledinthailand
AT jaransritharathikhun effectofambienttemperatureonperformanceofgridconnectedinverterinstalledinthailand
AT kobsaksriprapha effectofambienttemperatureonperformanceofgridconnectedinverterinstalledinthailand