Microfluidic Cooling System in High-Power Bare Chip Modules Based on New Process Technology

A closed-loop integrated microfluidic cooling system was designed to mitigate the heat dissipation problem in a high-power bare chip. The heat dissipation capabilities of a microchannel manufactured in the cavity and an unmanufactured cavity were compared. Moreover, the heat dissipation capabilities...