Investigation of the Composite Motor Load in the Presence of Higher Harmonics in the Electrical Network

The article discusses the methods of substitution of a compound motor load as a consumer of higher harmonics. Two substitution schemes were used. The calculation of the complex resistance against them was compared with the results of simulation modeling. The simulation was carried out in the MATLAB...

Full description

Saved in:
Bibliographic Details
Main Authors: Ya. E. Shklyarskiy, K. K. Lobko, Yu. N. Kuznetsova, M. S. Vorobyov
Format: Article
Language:Russian
Published: Belarusian National Technical University 2024-08-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/2387
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832557344048807936
author Ya. E. Shklyarskiy
K. K. Lobko
Yu. N. Kuznetsova
M. S. Vorobyov
author_facet Ya. E. Shklyarskiy
K. K. Lobko
Yu. N. Kuznetsova
M. S. Vorobyov
author_sort Ya. E. Shklyarskiy
collection DOAJ
description The article discusses the methods of substitution of a compound motor load as a consumer of higher harmonics. Two substitution schemes were used. The calculation of the complex resistance against them was compared with the results of simulation modeling. The simulation was carried out in the MATLAB Simulink environment, with the use of the Specialized Power Systems library, in which a simulation model with motors and a source of harmonic distortion was developed. Five asynchronous motors with a squirrel-cage rotor of the AIR brand with powers varying from 0.75 to 5.50 kW were selected for the study. The simulation was carried out at different motor loads. The shaft torque varied with values of 50; 70; 90 and 100 % of the nominal values of each motor. A six-pulse diode rectifier was used as a source of harmonic currents in the network, generating harmonics with numbers 5, 7, ..., 25, corresponding to a pulse rate equal to six. Oscillograms of currents and voltages were recorded at the point of common connection of asynchronous motors and the rectifier, which were subsequently used to calculate the complex resistance. Based on the results of the work, amplitude-frequency and phase-frequency characteristics of the impedance of a composite motor load were obtained, the analysis of which revealed the incongruence of calculation methods with simulation modeling. Conclusions have been drawn on the need to continue research in this direction, since there are qualitative discrepancies in the functional dependence of the complex resistance on the harmonic number with the experimental data obtained for a single asynchronous motor. The results of the work can be used in calculating the voltage distortion factor and modeling modes associated with higher harmonics both at existing enterprises and during their design, which will increase the reliability and efficiency of electrical networks.
format Article
id doaj-art-eddbb46f20bc4b9bb497625d3951d791
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2024-08-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-eddbb46f20bc4b9bb497625d3951d7912025-02-03T05:20:04ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412024-08-0167428529910.21122/1029-7448-2024-67-4-285-2991898Investigation of the Composite Motor Load in the Presence of Higher Harmonics in the Electrical NetworkYa. E. Shklyarskiy0K. K. Lobko1Yu. N. Kuznetsova2M. S. Vorobyov3Empress Catherine II Saint Petersburg Mining UniversityEmpress Catherine II Saint Petersburg Mining UniversityEmpress Catherine II Saint Petersburg Mining UniversityEmpress Catherine II Saint Petersburg Mining UniversityThe article discusses the methods of substitution of a compound motor load as a consumer of higher harmonics. Two substitution schemes were used. The calculation of the complex resistance against them was compared with the results of simulation modeling. The simulation was carried out in the MATLAB Simulink environment, with the use of the Specialized Power Systems library, in which a simulation model with motors and a source of harmonic distortion was developed. Five asynchronous motors with a squirrel-cage rotor of the AIR brand with powers varying from 0.75 to 5.50 kW were selected for the study. The simulation was carried out at different motor loads. The shaft torque varied with values of 50; 70; 90 and 100 % of the nominal values of each motor. A six-pulse diode rectifier was used as a source of harmonic currents in the network, generating harmonics with numbers 5, 7, ..., 25, corresponding to a pulse rate equal to six. Oscillograms of currents and voltages were recorded at the point of common connection of asynchronous motors and the rectifier, which were subsequently used to calculate the complex resistance. Based on the results of the work, amplitude-frequency and phase-frequency characteristics of the impedance of a composite motor load were obtained, the analysis of which revealed the incongruence of calculation methods with simulation modeling. Conclusions have been drawn on the need to continue research in this direction, since there are qualitative discrepancies in the functional dependence of the complex resistance on the harmonic number with the experimental data obtained for a single asynchronous motor. The results of the work can be used in calculating the voltage distortion factor and modeling modes associated with higher harmonics both at existing enterprises and during their design, which will increase the reliability and efficiency of electrical networks.https://energy.bntu.by/jour/article/view/2387higher harmonicspower qualityequivalent circuitimpedancedistortion facto
spellingShingle Ya. E. Shklyarskiy
K. K. Lobko
Yu. N. Kuznetsova
M. S. Vorobyov
Investigation of the Composite Motor Load in the Presence of Higher Harmonics in the Electrical Network
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
higher harmonics
power quality
equivalent circuit
impedance
distortion facto
title Investigation of the Composite Motor Load in the Presence of Higher Harmonics in the Electrical Network
title_full Investigation of the Composite Motor Load in the Presence of Higher Harmonics in the Electrical Network
title_fullStr Investigation of the Composite Motor Load in the Presence of Higher Harmonics in the Electrical Network
title_full_unstemmed Investigation of the Composite Motor Load in the Presence of Higher Harmonics in the Electrical Network
title_short Investigation of the Composite Motor Load in the Presence of Higher Harmonics in the Electrical Network
title_sort investigation of the composite motor load in the presence of higher harmonics in the electrical network
topic higher harmonics
power quality
equivalent circuit
impedance
distortion facto
url https://energy.bntu.by/jour/article/view/2387
work_keys_str_mv AT yaeshklyarskiy investigationofthecompositemotorloadinthepresenceofhigherharmonicsintheelectricalnetwork
AT kklobko investigationofthecompositemotorloadinthepresenceofhigherharmonicsintheelectricalnetwork
AT yunkuznetsova investigationofthecompositemotorloadinthepresenceofhigherharmonicsintheelectricalnetwork
AT msvorobyov investigationofthecompositemotorloadinthepresenceofhigherharmonicsintheelectricalnetwork