Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker
Compared with traditional leads, carbon fiber composite leads have a series of advantages such as lightweight, soft texture, and high conductivity. In this experiment, we attempted to improve the existing carbon-fiber-based TTCP metal leads by using carbon-fiber-graphene-woven leads or conductive cl...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2021-01-01
|
Series: | Bioinorganic Chemistry and Applications |
Online Access: | http://dx.doi.org/10.1155/2021/7507555 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832546094250196992 |
---|---|
author | Yucheng Zhou Xuming Lin Zhao Yang Xiaotong Han Meng Liu |
author_facet | Yucheng Zhou Xuming Lin Zhao Yang Xiaotong Han Meng Liu |
author_sort | Yucheng Zhou |
collection | DOAJ |
description | Compared with traditional leads, carbon fiber composite leads have a series of advantages such as lightweight, soft texture, and high conductivity. In this experiment, we attempted to improve the existing carbon-fiber-based TTCP metal leads by using carbon-fiber-graphene-woven leads or conductive cloth, so as to solve a series of defects of TTCP metal leads commonly used in the clinical temporary cardiac pacemaker. We performed a series of measurements, including resistance comparisons and stability checks on the finished product characteristics. The results showed that the resistivity of the whole lead did not change significantly after modification, and the carbon fiber bundle was stable and easily deformed under lower stress to reduce the damage to the myocardium, which had excellent clinical application value. |
format | Article |
id | doaj-art-dee118a82e244ccc870bb47f75750677 |
institution | Kabale University |
issn | 1565-3633 1687-479X |
language | English |
publishDate | 2021-01-01 |
publisher | Wiley |
record_format | Article |
series | Bioinorganic Chemistry and Applications |
spelling | doaj-art-dee118a82e244ccc870bb47f757506772025-02-03T07:24:02ZengWileyBioinorganic Chemistry and Applications1565-36331687-479X2021-01-01202110.1155/2021/75075557507555Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac PacemakerYucheng Zhou0Xuming Lin1Zhao Yang2Xiaotong Han3Meng Liu4Emergency Department, Hunan Provincial People’s Hospital, The First-Affiliate Hospital of Hunan Normal University, Changsha, Hunan 410005, ChinaElectromyogram Department, Hunan Province Hospital of Chinese Medicine, The Second-Affiliate Hospital of Hunan University of Chinese Medicine, Changsha, Hunan 410005, ChinaEmergency Department, Hunan Provincial People’s Hospital, The First-Affiliate Hospital of Hunan Normal University, Changsha, Hunan 410005, ChinaEmergency Department, Hunan Provincial People’s Hospital, The First-Affiliate Hospital of Hunan Normal University, Changsha, Hunan 410005, ChinaEmergency Department, Hunan Provincial People’s Hospital, The First-Affiliate Hospital of Hunan Normal University, Changsha, Hunan 410005, ChinaCompared with traditional leads, carbon fiber composite leads have a series of advantages such as lightweight, soft texture, and high conductivity. In this experiment, we attempted to improve the existing carbon-fiber-based TTCP metal leads by using carbon-fiber-graphene-woven leads or conductive cloth, so as to solve a series of defects of TTCP metal leads commonly used in the clinical temporary cardiac pacemaker. We performed a series of measurements, including resistance comparisons and stability checks on the finished product characteristics. The results showed that the resistivity of the whole lead did not change significantly after modification, and the carbon fiber bundle was stable and easily deformed under lower stress to reduce the damage to the myocardium, which had excellent clinical application value.http://dx.doi.org/10.1155/2021/7507555 |
spellingShingle | Yucheng Zhou Xuming Lin Zhao Yang Xiaotong Han Meng Liu Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker Bioinorganic Chemistry and Applications |
title | Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title_full | Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title_fullStr | Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title_full_unstemmed | Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title_short | Fabrication of a Lead Head Made of the Carbon-Fiber-Reinforced Composite for the Temporary Cardiac Pacemaker |
title_sort | fabrication of a lead head made of the carbon fiber reinforced composite for the temporary cardiac pacemaker |
url | http://dx.doi.org/10.1155/2021/7507555 |
work_keys_str_mv | AT yuchengzhou fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker AT xuminglin fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker AT zhaoyang fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker AT xiaotonghan fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker AT mengliu fabricationofaleadheadmadeofthecarbonfiberreinforcedcompositeforthetemporarycardiacpacemaker |