Tensile Failure Mechanism of Antiseepage System for Slope with Solid Waste Underground Landfill

The antiseepage membrane applied to the slope of solid waste landfill often shows tensile failure in projects, which results in ineffective antiseepage system and serious environmental pollution. In order to ensure the practical performance of the antiseepage membrane, the tensile force of it was st...

Full description

Saved in:
Bibliographic Details
Main Authors: Liu Fei, Zhongxi Jiang
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2018/9784185
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832545746446974976
author Liu Fei
Zhongxi Jiang
author_facet Liu Fei
Zhongxi Jiang
author_sort Liu Fei
collection DOAJ
description The antiseepage membrane applied to the slope of solid waste landfill often shows tensile failure in projects, which results in ineffective antiseepage system and serious environmental pollution. In order to ensure the practical performance of the antiseepage membrane, the tensile force of it was studied, and the settlement mechanical model of the interaction between landfill body, antiseepage membrane, and cushion was established after comprehensively considering the effects of dead weight, lateral pressure, settlement, and foundation boundary. The analytical solutions of the tensile force and displacement of the antiseepage membrane was calculated through differential equation of equilibrium. With general slag and ardealite slag as the research objects, the major parameters affecting the internal tensile force of the antiseepage membrane were analyzed and studied by the combination of numerical and theoretical methods. The results show that the internal tensile force of the antiseepage membrane is greatly affected by the parameters such as the membrane-slag interface friction angle, the membrane-cushion interface friction angle, the buried depth, and the single step height. The theoretical slope normal stress and membrane pull-up force are basically consistent with the numerical calculation results, which indicates that the theory is universally applicable to tackle the tensile failure of the antiseepage membrane in the solid waste landfill system.
format Article
id doaj-art-dbd31d2cd42943b09bfe9d5d5e08fec8
institution Kabale University
issn 1687-8086
1687-8094
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-dbd31d2cd42943b09bfe9d5d5e08fec82025-02-03T07:24:50ZengWileyAdvances in Civil Engineering1687-80861687-80942018-01-01201810.1155/2018/97841859784185Tensile Failure Mechanism of Antiseepage System for Slope with Solid Waste Underground LandfillLiu Fei0Zhongxi Jiang1Anhui Province Coal Mine Exploration Engineering Technology Research Center, Suzhou University, Suzhou 234000, ChinaShenzhen Research Institute, Shanghai Jiao Tong University, Shenzhen 518057, ChinaThe antiseepage membrane applied to the slope of solid waste landfill often shows tensile failure in projects, which results in ineffective antiseepage system and serious environmental pollution. In order to ensure the practical performance of the antiseepage membrane, the tensile force of it was studied, and the settlement mechanical model of the interaction between landfill body, antiseepage membrane, and cushion was established after comprehensively considering the effects of dead weight, lateral pressure, settlement, and foundation boundary. The analytical solutions of the tensile force and displacement of the antiseepage membrane was calculated through differential equation of equilibrium. With general slag and ardealite slag as the research objects, the major parameters affecting the internal tensile force of the antiseepage membrane were analyzed and studied by the combination of numerical and theoretical methods. The results show that the internal tensile force of the antiseepage membrane is greatly affected by the parameters such as the membrane-slag interface friction angle, the membrane-cushion interface friction angle, the buried depth, and the single step height. The theoretical slope normal stress and membrane pull-up force are basically consistent with the numerical calculation results, which indicates that the theory is universally applicable to tackle the tensile failure of the antiseepage membrane in the solid waste landfill system.http://dx.doi.org/10.1155/2018/9784185
spellingShingle Liu Fei
Zhongxi Jiang
Tensile Failure Mechanism of Antiseepage System for Slope with Solid Waste Underground Landfill
Advances in Civil Engineering
title Tensile Failure Mechanism of Antiseepage System for Slope with Solid Waste Underground Landfill
title_full Tensile Failure Mechanism of Antiseepage System for Slope with Solid Waste Underground Landfill
title_fullStr Tensile Failure Mechanism of Antiseepage System for Slope with Solid Waste Underground Landfill
title_full_unstemmed Tensile Failure Mechanism of Antiseepage System for Slope with Solid Waste Underground Landfill
title_short Tensile Failure Mechanism of Antiseepage System for Slope with Solid Waste Underground Landfill
title_sort tensile failure mechanism of antiseepage system for slope with solid waste underground landfill
url http://dx.doi.org/10.1155/2018/9784185
work_keys_str_mv AT liufei tensilefailuremechanismofantiseepagesystemforslopewithsolidwasteundergroundlandfill
AT zhongxijiang tensilefailuremechanismofantiseepagesystemforslopewithsolidwasteundergroundlandfill