Clinical evaluation of corneal ulcer with a portable and smartphone-attachable slit lamp device: Smart Eye Camera

Abstract Corneal ulcer is one of the most important ophthalmic emergencies. A portable, recordable, and smartphone-attachable slit-lamp device called the “Smart Eye Camera” (SEC) is introduced to compare evaluating corneal ulcers between the SEC and the conventional slit-lamp. A total of 110 partici...

Full description

Saved in:
Bibliographic Details
Main Authors: Sadegh Ghafarian, Ahmad Masoumi, Seyed Ali Tabatabaei, Mehdi Yaseri, Eisuke Shimizu, Shintaro Nakayama, Rohan Jeetendra Khemlani, Hiroki Nishimura, Hassan Asadigandomani
Format: Article
Language:English
Published: Nature Portfolio 2025-01-01
Series:Scientific Reports
Subjects:
Online Access:https://doi.org/10.1038/s41598-025-87820-z
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832585876692008960
author Sadegh Ghafarian
Ahmad Masoumi
Seyed Ali Tabatabaei
Mehdi Yaseri
Eisuke Shimizu
Shintaro Nakayama
Rohan Jeetendra Khemlani
Hiroki Nishimura
Hassan Asadigandomani
author_facet Sadegh Ghafarian
Ahmad Masoumi
Seyed Ali Tabatabaei
Mehdi Yaseri
Eisuke Shimizu
Shintaro Nakayama
Rohan Jeetendra Khemlani
Hiroki Nishimura
Hassan Asadigandomani
author_sort Sadegh Ghafarian
collection DOAJ
description Abstract Corneal ulcer is one of the most important ophthalmic emergencies. A portable, recordable, and smartphone-attachable slit-lamp device called the “Smart Eye Camera” (SEC) is introduced to compare evaluating corneal ulcers between the SEC and the conventional slit-lamp. A total of 110 participants were included in the study, consisting of 55 patients with corneal ulcers and 55 age- and gender-matched healthy volunteers as controls. The participants were first subjected to examination by a conventional slit lamp. The video recording with SEC and imaging with a slit lamp were done by a non-medical person. Both SEC videos and slit-lamp photos were reported by two independent ophthalmologists and compared with a slit-lamp examination as a gold standard. The average age of the study participants was 48.85 ± 20.45 years and 68 participants (61.8%) were male. All corneal ulcers were detected by two ophthalmologists using SEC. Ulcer size evaluated in slit lamp and SEC horizontally (Intraclass Correlation Coefficient (ICC); 0.90, 95% CI; 0.84–0.94) and vertically (ICC; 0.90, 95% CI; 0.84–0.94) is correlated about 90%. Hypopyon size (ICC; 0.95, 95% CI; 0.92–0.97), and corneal epithelial defect (CED) size horizontally (ICC; 0.94, 95% CI; 0.91–0.96) and vertically (ICC; 0.94, 95% CI; 0.91–0.96) also correlated about 94%. The infiltration pattern evaluated by SEC was consistent with the pattern evaluated in slit lamps in more than 80% of patients. The SEC is so accurate in diagnosing corneal ulcers and its reliability makes it a valuable telemedicine device.
format Article
id doaj-art-d07ee97c137a4545b70b7038dca137f8
institution Kabale University
issn 2045-2322
language English
publishDate 2025-01-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj-art-d07ee97c137a4545b70b7038dca137f82025-01-26T12:26:17ZengNature PortfolioScientific Reports2045-23222025-01-0115111110.1038/s41598-025-87820-zClinical evaluation of corneal ulcer with a portable and smartphone-attachable slit lamp device: Smart Eye CameraSadegh Ghafarian0Ahmad Masoumi1Seyed Ali Tabatabaei2Mehdi Yaseri3Eisuke Shimizu4Shintaro Nakayama5Rohan Jeetendra Khemlani6Hiroki Nishimura7Hassan Asadigandomani8Eye Research Center, Farabi Eye Hospital, Tehran University of Medical SciencesEye Research Center, Farabi Eye Hospital, Tehran University of Medical SciencesEye Research Center, Farabi Eye Hospital, Tehran University of Medical SciencesDepartment of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical SciencesDepartment of Ophthalmology, Keio University School of MedicineDepartment of Ophthalmology, Keio University School of MedicineOUI Inc.Department of Ophthalmology, Keio University School of MedicineEye Research Center, Farabi Eye Hospital, Tehran University of Medical SciencesAbstract Corneal ulcer is one of the most important ophthalmic emergencies. A portable, recordable, and smartphone-attachable slit-lamp device called the “Smart Eye Camera” (SEC) is introduced to compare evaluating corneal ulcers between the SEC and the conventional slit-lamp. A total of 110 participants were included in the study, consisting of 55 patients with corneal ulcers and 55 age- and gender-matched healthy volunteers as controls. The participants were first subjected to examination by a conventional slit lamp. The video recording with SEC and imaging with a slit lamp were done by a non-medical person. Both SEC videos and slit-lamp photos were reported by two independent ophthalmologists and compared with a slit-lamp examination as a gold standard. The average age of the study participants was 48.85 ± 20.45 years and 68 participants (61.8%) were male. All corneal ulcers were detected by two ophthalmologists using SEC. Ulcer size evaluated in slit lamp and SEC horizontally (Intraclass Correlation Coefficient (ICC); 0.90, 95% CI; 0.84–0.94) and vertically (ICC; 0.90, 95% CI; 0.84–0.94) is correlated about 90%. Hypopyon size (ICC; 0.95, 95% CI; 0.92–0.97), and corneal epithelial defect (CED) size horizontally (ICC; 0.94, 95% CI; 0.91–0.96) and vertically (ICC; 0.94, 95% CI; 0.91–0.96) also correlated about 94%. The infiltration pattern evaluated by SEC was consistent with the pattern evaluated in slit lamps in more than 80% of patients. The SEC is so accurate in diagnosing corneal ulcers and its reliability makes it a valuable telemedicine device.https://doi.org/10.1038/s41598-025-87820-zCorneal ulcerMicrobial keratitisSmart Eye CameraSECTelemedicine
spellingShingle Sadegh Ghafarian
Ahmad Masoumi
Seyed Ali Tabatabaei
Mehdi Yaseri
Eisuke Shimizu
Shintaro Nakayama
Rohan Jeetendra Khemlani
Hiroki Nishimura
Hassan Asadigandomani
Clinical evaluation of corneal ulcer with a portable and smartphone-attachable slit lamp device: Smart Eye Camera
Scientific Reports
Corneal ulcer
Microbial keratitis
Smart Eye Camera
SEC
Telemedicine
title Clinical evaluation of corneal ulcer with a portable and smartphone-attachable slit lamp device: Smart Eye Camera
title_full Clinical evaluation of corneal ulcer with a portable and smartphone-attachable slit lamp device: Smart Eye Camera
title_fullStr Clinical evaluation of corneal ulcer with a portable and smartphone-attachable slit lamp device: Smart Eye Camera
title_full_unstemmed Clinical evaluation of corneal ulcer with a portable and smartphone-attachable slit lamp device: Smart Eye Camera
title_short Clinical evaluation of corneal ulcer with a portable and smartphone-attachable slit lamp device: Smart Eye Camera
title_sort clinical evaluation of corneal ulcer with a portable and smartphone attachable slit lamp device smart eye camera
topic Corneal ulcer
Microbial keratitis
Smart Eye Camera
SEC
Telemedicine
url https://doi.org/10.1038/s41598-025-87820-z
work_keys_str_mv AT sadeghghafarian clinicalevaluationofcornealulcerwithaportableandsmartphoneattachableslitlampdevicesmarteyecamera
AT ahmadmasoumi clinicalevaluationofcornealulcerwithaportableandsmartphoneattachableslitlampdevicesmarteyecamera
AT seyedalitabatabaei clinicalevaluationofcornealulcerwithaportableandsmartphoneattachableslitlampdevicesmarteyecamera
AT mehdiyaseri clinicalevaluationofcornealulcerwithaportableandsmartphoneattachableslitlampdevicesmarteyecamera
AT eisukeshimizu clinicalevaluationofcornealulcerwithaportableandsmartphoneattachableslitlampdevicesmarteyecamera
AT shintaronakayama clinicalevaluationofcornealulcerwithaportableandsmartphoneattachableslitlampdevicesmarteyecamera
AT rohanjeetendrakhemlani clinicalevaluationofcornealulcerwithaportableandsmartphoneattachableslitlampdevicesmarteyecamera
AT hirokinishimura clinicalevaluationofcornealulcerwithaportableandsmartphoneattachableslitlampdevicesmarteyecamera
AT hassanasadigandomani clinicalevaluationofcornealulcerwithaportableandsmartphoneattachableslitlampdevicesmarteyecamera