Analysis of Nabumetone in Bulk and Tablet Formulation by a New and Validated Reverse Phase High Performance Liquid Chromatography
RP-HPLC analytical method for the estimation of nabumetone in pharmaceutical dosage forms was developed and validated. A Hypersil ODS C18, 4.6 mm x 250 mm, 5 μm column from Supelco (India), with mobile phase comprised of acetonitrile: triple distilled water (50:50) with a total run time of 18 min wa...