An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS

A high throughput sample preparation method was developed utilizing mixed-mode solid phase extraction (SPE) in 96-well plate format for the determination of free arachidonic acid in plasma by LC-MS/MS. Plasma was mixed with 3% aqueous ammonia and loaded into each well of 96-well plate. After washing...

Full description

Saved in:
Bibliographic Details
Main Authors: Wan Wang, Suzi Qin, Linsen Li, Xiaohua Chen, Qunjie Wang, Junfu Wei
Format: Article
Language:English
Published: Wiley 2015-01-01
Series:International Journal of Analytical Chemistry
Online Access:http://dx.doi.org/10.1155/2015/374819
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832561458727092224
author Wan Wang
Suzi Qin
Linsen Li
Xiaohua Chen
Qunjie Wang
Junfu Wei
author_facet Wan Wang
Suzi Qin
Linsen Li
Xiaohua Chen
Qunjie Wang
Junfu Wei
author_sort Wan Wang
collection DOAJ
description A high throughput sample preparation method was developed utilizing mixed-mode solid phase extraction (SPE) in 96-well plate format for the determination of free arachidonic acid in plasma by LC-MS/MS. Plasma was mixed with 3% aqueous ammonia and loaded into each well of 96-well plate. After washing with water and methanol sequentially, 3% of formic acid in acetonitrile was used to elute arachidonic acid. The collected fraction was injected onto a reversed phase column at 30°C with mobile phase of acetonitrile/water (70 : 30, v/v) and detected by LC-MS/MS coupled with electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The calibration curve ranged from 10 to 2500 ng/mL with sufficient linearity (r2 = 0.9999). The recoveries were in the range of 99.38% to 103.21% with RSD less than 6%. The limit of detection is 3 ng/mL.
format Article
id doaj-art-cac76bba11ec48618b2f1285c44438a8
institution Kabale University
issn 1687-8760
1687-8779
language English
publishDate 2015-01-01
publisher Wiley
record_format Article
series International Journal of Analytical Chemistry
spelling doaj-art-cac76bba11ec48618b2f1285c44438a82025-02-03T01:25:07ZengWileyInternational Journal of Analytical Chemistry1687-87601687-87792015-01-01201510.1155/2015/374819374819An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MSWan Wang0Suzi Qin1Linsen Li2Xiaohua Chen3Qunjie Wang4Junfu Wei5School of Material Science and Engineering, Tianjin Polytechnic University, Tianjin 300387, ChinaBonna-Agela Technologies, Tianjin 300462, ChinaBonna-Agela Technologies, Tianjin 300462, ChinaBonna-Agela Technologies, Tianjin 300462, ChinaBonna-Agela Technologies, Tianjin 300462, ChinaSchool of Environment & Chemical Engineering, Tianjin Polytechnic University, Tianjin 300387, ChinaA high throughput sample preparation method was developed utilizing mixed-mode solid phase extraction (SPE) in 96-well plate format for the determination of free arachidonic acid in plasma by LC-MS/MS. Plasma was mixed with 3% aqueous ammonia and loaded into each well of 96-well plate. After washing with water and methanol sequentially, 3% of formic acid in acetonitrile was used to elute arachidonic acid. The collected fraction was injected onto a reversed phase column at 30°C with mobile phase of acetonitrile/water (70 : 30, v/v) and detected by LC-MS/MS coupled with electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The calibration curve ranged from 10 to 2500 ng/mL with sufficient linearity (r2 = 0.9999). The recoveries were in the range of 99.38% to 103.21% with RSD less than 6%. The limit of detection is 3 ng/mL.http://dx.doi.org/10.1155/2015/374819
spellingShingle Wan Wang
Suzi Qin
Linsen Li
Xiaohua Chen
Qunjie Wang
Junfu Wei
An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS
International Journal of Analytical Chemistry
title An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS
title_full An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS
title_fullStr An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS
title_full_unstemmed An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS
title_short An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS
title_sort optimized high throughput clean up method using mixed mode spe plate for the analysis of free arachidonic acid in plasma by lc ms ms
url http://dx.doi.org/10.1155/2015/374819
work_keys_str_mv AT wanwang anoptimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT suziqin anoptimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT linsenli anoptimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT xiaohuachen anoptimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT qunjiewang anoptimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT junfuwei anoptimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT wanwang optimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT suziqin optimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT linsenli optimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT xiaohuachen optimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT qunjiewang optimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms
AT junfuwei optimizedhighthroughputcleanupmethodusingmixedmodespeplatefortheanalysisoffreearachidonicacidinplasmabylcmsms