Direct Analysis of Low-Volatile Molecular Marker Extract from Airborne Particulate Matter Using Sensitivity Correction Method

Molecular marker analysis of environmental samples often requires time consuming preseparation steps. Here, analysis of low-volatile nonpolar molecular markers (5-6 ring polycyclic aromatic hydrocarbons or PAHs, hopanoids, and n-alkanes) without the preseparation procedure is presented. Analysis of...

Full description

Saved in:
Bibliographic Details
Main Author: Satoshi Irei
Format: Article
Language:English
Published: Wiley 2016-01-01
Series:International Journal of Analytical Chemistry
Online Access:http://dx.doi.org/10.1155/2016/2834575
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832556018960171008
author Satoshi Irei
author_facet Satoshi Irei
author_sort Satoshi Irei
collection DOAJ
description Molecular marker analysis of environmental samples often requires time consuming preseparation steps. Here, analysis of low-volatile nonpolar molecular markers (5-6 ring polycyclic aromatic hydrocarbons or PAHs, hopanoids, and n-alkanes) without the preseparation procedure is presented. Analysis of artificial sample extracts was directly conducted by gas chromatography-mass spectrometry (GC-MS). After every sample injection, a standard mixture was also analyzed to make a correction on the variation of instrumental sensitivity caused by the unfavorable matrix contained in the extract. The method was further validated for the PAHs using the NIST standard reference materials (SRMs) and then applied to airborne particulate matter samples. Tests with the SRMs showed that overall our methodology was validated with the uncertainty of ~30%. The measurement results of airborne particulate matter (PM) filter samples showed a strong correlation between the PAHs, implying the contributions from the same emission source. Analysis of size-segregated PM filter samples showed that their size distributions were found to be in the PM smaller than 0.4 μm aerodynamic diameter. The observations were consistent with our expectation of their possible sources. Thus, the method was found to be useful for molecular marker studies.
format Article
id doaj-art-c5ea41f1684c45bfb269f15e4a6a597b
institution Kabale University
issn 1687-8760
1687-8779
language English
publishDate 2016-01-01
publisher Wiley
record_format Article
series International Journal of Analytical Chemistry
spelling doaj-art-c5ea41f1684c45bfb269f15e4a6a597b2025-02-03T05:46:42ZengWileyInternational Journal of Analytical Chemistry1687-87601687-87792016-01-01201610.1155/2016/28345752834575Direct Analysis of Low-Volatile Molecular Marker Extract from Airborne Particulate Matter Using Sensitivity Correction MethodSatoshi Irei0Centre for Atmospheric Chemistry and Department of Chemistry, York University, 4700 Keels Street, Toronto, ON, M3J 1P3, CanadaMolecular marker analysis of environmental samples often requires time consuming preseparation steps. Here, analysis of low-volatile nonpolar molecular markers (5-6 ring polycyclic aromatic hydrocarbons or PAHs, hopanoids, and n-alkanes) without the preseparation procedure is presented. Analysis of artificial sample extracts was directly conducted by gas chromatography-mass spectrometry (GC-MS). After every sample injection, a standard mixture was also analyzed to make a correction on the variation of instrumental sensitivity caused by the unfavorable matrix contained in the extract. The method was further validated for the PAHs using the NIST standard reference materials (SRMs) and then applied to airborne particulate matter samples. Tests with the SRMs showed that overall our methodology was validated with the uncertainty of ~30%. The measurement results of airborne particulate matter (PM) filter samples showed a strong correlation between the PAHs, implying the contributions from the same emission source. Analysis of size-segregated PM filter samples showed that their size distributions were found to be in the PM smaller than 0.4 μm aerodynamic diameter. The observations were consistent with our expectation of their possible sources. Thus, the method was found to be useful for molecular marker studies.http://dx.doi.org/10.1155/2016/2834575
spellingShingle Satoshi Irei
Direct Analysis of Low-Volatile Molecular Marker Extract from Airborne Particulate Matter Using Sensitivity Correction Method
International Journal of Analytical Chemistry
title Direct Analysis of Low-Volatile Molecular Marker Extract from Airborne Particulate Matter Using Sensitivity Correction Method
title_full Direct Analysis of Low-Volatile Molecular Marker Extract from Airborne Particulate Matter Using Sensitivity Correction Method
title_fullStr Direct Analysis of Low-Volatile Molecular Marker Extract from Airborne Particulate Matter Using Sensitivity Correction Method
title_full_unstemmed Direct Analysis of Low-Volatile Molecular Marker Extract from Airborne Particulate Matter Using Sensitivity Correction Method
title_short Direct Analysis of Low-Volatile Molecular Marker Extract from Airborne Particulate Matter Using Sensitivity Correction Method
title_sort direct analysis of low volatile molecular marker extract from airborne particulate matter using sensitivity correction method
url http://dx.doi.org/10.1155/2016/2834575
work_keys_str_mv AT satoshiirei directanalysisoflowvolatilemolecularmarkerextractfromairborneparticulatematterusingsensitivitycorrectionmethod