Design and Implementation of a Healthcare Monitoring System Based on LoRa

For humans to survive, scientific and technological advancements must be able to contribute to the solution of human medical issues. The design and implementation of a monitoring system for the measurement of blood oxygen saturation, heart rate, and body temperature have been combined into one tool...

Full description

Saved in:
Bibliographic Details
Main Authors: Hayder Fadhil Jawad, Ali Al-Askery, Adnan Hussein Ali
Format: Article
Language:English
Published: middle technical university 2022-12-01
Series:Journal of Techniques
Subjects:
Online Access:https://journal.mtu.edu.iq/index.php/MTU/article/view/792
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832595146858823680
author Hayder Fadhil Jawad
Ali Al-Askery
Adnan Hussein Ali
author_facet Hayder Fadhil Jawad
Ali Al-Askery
Adnan Hussein Ali
author_sort Hayder Fadhil Jawad
collection DOAJ
description For humans to survive, scientific and technological advancements must be able to contribute to the solution of human medical issues. The design and implementation of a monitoring system for the measurement of blood oxygen saturation, heart rate, and body temperature have been combined into one tool in this study. The measurement results are shown both on the measuring instrument's OLED display and a remote monitoring system's LCD display. This instrument uses ESP32 as a Microcontroller and LoRa as a wireless communication technique. The MLX90614 sensor is used to detect body temperature, while the MAX30100 sensor is used to monitor blood oxygen saturation and heart rate. Testing Measurements are calibrated using instruments that meet industrial standards (Wincom infrared thermometer and GE patient monitor) used in the hospital. When compared to industry-standard instruments, the tool's accuracy is 98.18% for measurements of blood oxygen saturation, 96.54 % for measurements of heart rate, and 98.78 % for measurements of body temperature. The instrument's total accuracy, calculated as the average of all three factors, was 97.63 %. If the abnormalities in the recorded parameters are detected, then an alert will be triggered (buzzer and blinking LED). this instrument can help the patients to check their health status and provide remote monitoring of health providers.
format Article
id doaj-art-c55fa46d49864fc183a96c764d0be96a
institution Kabale University
issn 1818-653X
2708-8383
language English
publishDate 2022-12-01
publisher middle technical university
record_format Article
series Journal of Techniques
spelling doaj-art-c55fa46d49864fc183a96c764d0be96a2025-01-19T11:02:01Zengmiddle technical universityJournal of Techniques1818-653X2708-83832022-12-014410.51173/jt.v4i4.792Design and Implementation of a Healthcare Monitoring System Based on LoRa Hayder Fadhil Jawad 0Ali Al-Askery1Adnan Hussein Ali2Electrical Engineering Technical College, Middle Technical University, Baghdad, Iraq.Electrical Engineering Technical College, Middle Technical University, Baghdad, Iraq.Institute of Technology / Baghdad, Middle Technical University, Baghdad, Iraq For humans to survive, scientific and technological advancements must be able to contribute to the solution of human medical issues. The design and implementation of a monitoring system for the measurement of blood oxygen saturation, heart rate, and body temperature have been combined into one tool in this study. The measurement results are shown both on the measuring instrument's OLED display and a remote monitoring system's LCD display. This instrument uses ESP32 as a Microcontroller and LoRa as a wireless communication technique. The MLX90614 sensor is used to detect body temperature, while the MAX30100 sensor is used to monitor blood oxygen saturation and heart rate. Testing Measurements are calibrated using instruments that meet industrial standards (Wincom infrared thermometer and GE patient monitor) used in the hospital. When compared to industry-standard instruments, the tool's accuracy is 98.18% for measurements of blood oxygen saturation, 96.54 % for measurements of heart rate, and 98.78 % for measurements of body temperature. The instrument's total accuracy, calculated as the average of all three factors, was 97.63 %. If the abnormalities in the recorded parameters are detected, then an alert will be triggered (buzzer and blinking LED). this instrument can help the patients to check their health status and provide remote monitoring of health providers. https://journal.mtu.edu.iq/index.php/MTU/article/view/792LoRaHealthCare StationMAX30100MLX90614
spellingShingle Hayder Fadhil Jawad
Ali Al-Askery
Adnan Hussein Ali
Design and Implementation of a Healthcare Monitoring System Based on LoRa
Journal of Techniques
LoRa
HealthCare Station
MAX30100
MLX90614
title Design and Implementation of a Healthcare Monitoring System Based on LoRa
title_full Design and Implementation of a Healthcare Monitoring System Based on LoRa
title_fullStr Design and Implementation of a Healthcare Monitoring System Based on LoRa
title_full_unstemmed Design and Implementation of a Healthcare Monitoring System Based on LoRa
title_short Design and Implementation of a Healthcare Monitoring System Based on LoRa
title_sort design and implementation of a healthcare monitoring system based on lora
topic LoRa
HealthCare Station
MAX30100
MLX90614
url https://journal.mtu.edu.iq/index.php/MTU/article/view/792
work_keys_str_mv AT hayderfadhiljawad designandimplementationofahealthcaremonitoringsystembasedonlora
AT alialaskery designandimplementationofahealthcaremonitoringsystembasedonlora
AT adnanhusseinali designandimplementationofahealthcaremonitoringsystembasedonlora