Development and Validation of a Rapid RP HPLC Method for the Determination of Cinitapride Hydrogen Tartarate in Solid Oral Dosage Forms

In the present study a simple, sensitive rapid and accurate HPLC method with UV detection for the analysis of cinitapride hydrogen tartarate was developed and validated in solid dosage forms. The method utilized gradient elution technique with C18 column (150×4.6 mm I.D, 5 μm particle size) with mob...

Full description

Saved in:
Bibliographic Details
Main Authors: Syeda Humaira, Akalanka Dey, S.Appala Raju, Syed Sanaullah
Format: Article
Language:English
Published: Wiley 2011-01-01
Series:E-Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2011/614160
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832547530527735808
author Syeda Humaira
Akalanka Dey
S.Appala Raju
Syed Sanaullah
author_facet Syeda Humaira
Akalanka Dey
S.Appala Raju
Syed Sanaullah
author_sort Syeda Humaira
collection DOAJ
description In the present study a simple, sensitive rapid and accurate HPLC method with UV detection for the analysis of cinitapride hydrogen tartarate was developed and validated in solid dosage forms. The method utilized gradient elution technique with C18 column (150×4.6 mm I.D, 5 μm particle size) with mobile phase consisting of 0.1% formic acid in water and acetonitrile The detection wavelength was at 268 nm, with flow rate of 0.5 mL/min and injection volume of 10 μL for separation of cinitapride in bulk drugs and pharmaceutical formulations. The gradient elution was developed for better and optimized results. The developed method was validated for precision which includes system precision and method precision, accuracy and linearity studies in the concentration range of 5-100 μg/mL with correlation coefficient of 0.9987. The accuracy (recovery) was between 97.32 and 100.82%. The proposed method is simple, fast, accurate, precise and reproducible, hence can be applied for routine quality control analysis of cinitapride in pure and pharmaceutical dosage forms.
format Article
id doaj-art-c49652bdec7843c1898a53b6d73ba56b
institution Kabale University
issn 0973-4945
2090-9810
language English
publishDate 2011-01-01
publisher Wiley
record_format Article
series E-Journal of Chemistry
spelling doaj-art-c49652bdec7843c1898a53b6d73ba56b2025-02-03T06:44:27ZengWileyE-Journal of Chemistry0973-49452090-98102011-01-01831424142910.1155/2011/614160Development and Validation of a Rapid RP HPLC Method for the Determination of Cinitapride Hydrogen Tartarate in Solid Oral Dosage FormsSyeda Humaira0Akalanka Dey1S.Appala Raju2Syed Sanaullah3Department of Pharmacy, Annamalai UniversityChidambaram, Tamilnadu, IndiaDepartment of Pharmacy, Annamalai UniversityChidambaram, Tamilnadu, IndiaH.K.E’s College of Pharmacy Sedam Road, Gulbarga, Karnataka, IndiaLuqman College of Pharmacy, Behind P & T QuartersOld jewargi Road, Gulbarga, IndiaIn the present study a simple, sensitive rapid and accurate HPLC method with UV detection for the analysis of cinitapride hydrogen tartarate was developed and validated in solid dosage forms. The method utilized gradient elution technique with C18 column (150×4.6 mm I.D, 5 μm particle size) with mobile phase consisting of 0.1% formic acid in water and acetonitrile The detection wavelength was at 268 nm, with flow rate of 0.5 mL/min and injection volume of 10 μL for separation of cinitapride in bulk drugs and pharmaceutical formulations. The gradient elution was developed for better and optimized results. The developed method was validated for precision which includes system precision and method precision, accuracy and linearity studies in the concentration range of 5-100 μg/mL with correlation coefficient of 0.9987. The accuracy (recovery) was between 97.32 and 100.82%. The proposed method is simple, fast, accurate, precise and reproducible, hence can be applied for routine quality control analysis of cinitapride in pure and pharmaceutical dosage forms.http://dx.doi.org/10.1155/2011/614160
spellingShingle Syeda Humaira
Akalanka Dey
S.Appala Raju
Syed Sanaullah
Development and Validation of a Rapid RP HPLC Method for the Determination of Cinitapride Hydrogen Tartarate in Solid Oral Dosage Forms
E-Journal of Chemistry
title Development and Validation of a Rapid RP HPLC Method for the Determination of Cinitapride Hydrogen Tartarate in Solid Oral Dosage Forms
title_full Development and Validation of a Rapid RP HPLC Method for the Determination of Cinitapride Hydrogen Tartarate in Solid Oral Dosage Forms
title_fullStr Development and Validation of a Rapid RP HPLC Method for the Determination of Cinitapride Hydrogen Tartarate in Solid Oral Dosage Forms
title_full_unstemmed Development and Validation of a Rapid RP HPLC Method for the Determination of Cinitapride Hydrogen Tartarate in Solid Oral Dosage Forms
title_short Development and Validation of a Rapid RP HPLC Method for the Determination of Cinitapride Hydrogen Tartarate in Solid Oral Dosage Forms
title_sort development and validation of a rapid rp hplc method for the determination of cinitapride hydrogen tartarate in solid oral dosage forms
url http://dx.doi.org/10.1155/2011/614160
work_keys_str_mv AT syedahumaira developmentandvalidationofarapidrphplcmethodforthedeterminationofcinitapridehydrogentartarateinsolidoraldosageforms
AT akalankadey developmentandvalidationofarapidrphplcmethodforthedeterminationofcinitapridehydrogentartarateinsolidoraldosageforms
AT sappalaraju developmentandvalidationofarapidrphplcmethodforthedeterminationofcinitapridehydrogentartarateinsolidoraldosageforms
AT syedsanaullah developmentandvalidationofarapidrphplcmethodforthedeterminationofcinitapridehydrogentartarateinsolidoraldosageforms