Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement under Regional Anesthesia: A Retrospective Cohort Study

Background. Robot-assisted pedicle screw placement is usually performed under general anesthesia to keep the body still. The aim of this study was to compare the accuracy of the robot-assisted technique under regional anesthesia with that of conventional fluoroscopy-guided percutaneous pedicle screw...

Full description

Saved in:
Bibliographic Details
Main Authors: Shangju Gao, Jingchao Wei, Wenyi Li, Long Zhang, Can Cao, Jinshuai Zhai, Bo Gao
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Pain Research and Management
Online Access:http://dx.doi.org/10.1155/2021/6894001
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832563049534324736
author Shangju Gao
Jingchao Wei
Wenyi Li
Long Zhang
Can Cao
Jinshuai Zhai
Bo Gao
author_facet Shangju Gao
Jingchao Wei
Wenyi Li
Long Zhang
Can Cao
Jinshuai Zhai
Bo Gao
author_sort Shangju Gao
collection DOAJ
description Background. Robot-assisted pedicle screw placement is usually performed under general anesthesia to keep the body still. The aim of this study was to compare the accuracy of the robot-assisted technique under regional anesthesia with that of conventional fluoroscopy-guided percutaneous pedicle screw placement under general anesthesia in minimally invasive lumbar fusion surgery. Methods. This study recruited patients who underwent robot-assisted percutaneous endoscopic lumbar interbody fusion (PELIF) or fluoroscopy-guided minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) between December 2017 and February 2020 at a single center. Based on the method of percutaneous pedicle screw placement used, patients were divided into the robot-assisted under regional anesthesia (group RE-RO) and fluoroscopy-guided under general anesthesia (group GE-FLU) groups. The primary outcome measures were screw accuracy and the incidence of facet joint violation (FJV). Secondary outcome measures included X-ray and visual analogue scale (VAS) scores which were used to evaluate the degree of the postoperative pain at 4 hours and on postoperative days 1, 2, and 3. Intraoperative adverse events were also recorded. Results. Eighteen patients were included in group RE-RO, and 23 patients were included in group GE-FLU. The percentages of clinically acceptable screws (Gertzbein and Robbins grades A and B) were 94.4% and 91.5%, respectively. There was no significant difference in the percentages of clinically acceptable screws (p=0.44) or overall Gertzbein and Robbins screw accuracy grades (p=0.35). Only the top screws were included in the analysis of FJVs. The percentages of FJV (Babu grades 1, 2, and 3) were 5.6% and 28.3%, respectively. This difference was statistically significant (p=0.01). Overall, the FJV grades in group RE-RO were significantly better than those in group GE-FLU (p=0.009). The mean fluoroscopy time for each screw in group RE-RO was significantly shorter than that in group GE-FLU (group RE-RO: 5.4 ± 1.9 seconds and group GE-FLU: 6.8 ± 2.0 seconds; p=0.03). The postoperative pain between the RE-RO and GE-FLU groups was not statistically significant. The intraoperative adverse events included 1 case of registration failure and 1 case of guide-wire dislodgment in group RE-RO, as well as 2 cases of screw misplacement in group GE-FLU. No complications related to anesthesia were observed. Conclusion. Robot-assisted pedicle screw placement under regional anesthesia can be performed effectively and safely. The accuracy is comparable to the conventional technique. Moreover, this technique has the advantage of fewer FJVs and a lower radiation time.
format Article
id doaj-art-bf9a4e83f2c342fb9ad5bae0e825fb22
institution Kabale University
issn 1918-1523
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series Pain Research and Management
spelling doaj-art-bf9a4e83f2c342fb9ad5bae0e825fb222025-02-03T01:21:09ZengWileyPain Research and Management1918-15232021-01-01202110.1155/2021/6894001Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement under Regional Anesthesia: A Retrospective Cohort StudyShangju Gao0Jingchao Wei1Wenyi Li2Long Zhang3Can Cao4Jinshuai Zhai5Bo Gao6Department of OrthopedicsDepartment of OrthopedicsDepartment of OrthopedicsDepartment of OrthopedicsDepartment of OrthopedicsDepartment of OrthopedicsDepartment of OrthopedicsBackground. Robot-assisted pedicle screw placement is usually performed under general anesthesia to keep the body still. The aim of this study was to compare the accuracy of the robot-assisted technique under regional anesthesia with that of conventional fluoroscopy-guided percutaneous pedicle screw placement under general anesthesia in minimally invasive lumbar fusion surgery. Methods. This study recruited patients who underwent robot-assisted percutaneous endoscopic lumbar interbody fusion (PELIF) or fluoroscopy-guided minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) between December 2017 and February 2020 at a single center. Based on the method of percutaneous pedicle screw placement used, patients were divided into the robot-assisted under regional anesthesia (group RE-RO) and fluoroscopy-guided under general anesthesia (group GE-FLU) groups. The primary outcome measures were screw accuracy and the incidence of facet joint violation (FJV). Secondary outcome measures included X-ray and visual analogue scale (VAS) scores which were used to evaluate the degree of the postoperative pain at 4 hours and on postoperative days 1, 2, and 3. Intraoperative adverse events were also recorded. Results. Eighteen patients were included in group RE-RO, and 23 patients were included in group GE-FLU. The percentages of clinically acceptable screws (Gertzbein and Robbins grades A and B) were 94.4% and 91.5%, respectively. There was no significant difference in the percentages of clinically acceptable screws (p=0.44) or overall Gertzbein and Robbins screw accuracy grades (p=0.35). Only the top screws were included in the analysis of FJVs. The percentages of FJV (Babu grades 1, 2, and 3) were 5.6% and 28.3%, respectively. This difference was statistically significant (p=0.01). Overall, the FJV grades in group RE-RO were significantly better than those in group GE-FLU (p=0.009). The mean fluoroscopy time for each screw in group RE-RO was significantly shorter than that in group GE-FLU (group RE-RO: 5.4 ± 1.9 seconds and group GE-FLU: 6.8 ± 2.0 seconds; p=0.03). The postoperative pain between the RE-RO and GE-FLU groups was not statistically significant. The intraoperative adverse events included 1 case of registration failure and 1 case of guide-wire dislodgment in group RE-RO, as well as 2 cases of screw misplacement in group GE-FLU. No complications related to anesthesia were observed. Conclusion. Robot-assisted pedicle screw placement under regional anesthesia can be performed effectively and safely. The accuracy is comparable to the conventional technique. Moreover, this technique has the advantage of fewer FJVs and a lower radiation time.http://dx.doi.org/10.1155/2021/6894001
spellingShingle Shangju Gao
Jingchao Wei
Wenyi Li
Long Zhang
Can Cao
Jinshuai Zhai
Bo Gao
Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement under Regional Anesthesia: A Retrospective Cohort Study
Pain Research and Management
title Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement under Regional Anesthesia: A Retrospective Cohort Study
title_full Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement under Regional Anesthesia: A Retrospective Cohort Study
title_fullStr Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement under Regional Anesthesia: A Retrospective Cohort Study
title_full_unstemmed Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement under Regional Anesthesia: A Retrospective Cohort Study
title_short Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement under Regional Anesthesia: A Retrospective Cohort Study
title_sort accuracy of robot assisted percutaneous pedicle screw placement under regional anesthesia a retrospective cohort study
url http://dx.doi.org/10.1155/2021/6894001
work_keys_str_mv AT shangjugao accuracyofrobotassistedpercutaneouspediclescrewplacementunderregionalanesthesiaaretrospectivecohortstudy
AT jingchaowei accuracyofrobotassistedpercutaneouspediclescrewplacementunderregionalanesthesiaaretrospectivecohortstudy
AT wenyili accuracyofrobotassistedpercutaneouspediclescrewplacementunderregionalanesthesiaaretrospectivecohortstudy
AT longzhang accuracyofrobotassistedpercutaneouspediclescrewplacementunderregionalanesthesiaaretrospectivecohortstudy
AT cancao accuracyofrobotassistedpercutaneouspediclescrewplacementunderregionalanesthesiaaretrospectivecohortstudy
AT jinshuaizhai accuracyofrobotassistedpercutaneouspediclescrewplacementunderregionalanesthesiaaretrospectivecohortstudy
AT bogao accuracyofrobotassistedpercutaneouspediclescrewplacementunderregionalanesthesiaaretrospectivecohortstudy