Encrusted Ureteral Stent Retrieval Using Flexible Ureteroscopy with a Ho: YAG Laser

A 23-year-old female had bilateral ureteral stents placed due to bilateral renal stones and hydronephrosis. The bilateral ureteral stents were changed every 3 months. A kidney ureter bladder (KUB) film showed left encrustation along the ureteral stent thus necessitating removal; however, the uretera...

Full description

Saved in:
Bibliographic Details
Main Authors: Takashi Kawahara, Hiroki Ito, Hideyuki Terao, Takehiko Ogawa, Hiroji Uemura, Yoshinobu Kubota, Junichi Matsuzaki
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:Case Reports in Medicine
Online Access:http://dx.doi.org/10.1155/2012/862539
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A 23-year-old female had bilateral ureteral stents placed due to bilateral renal stones and hydronephrosis. The bilateral ureteral stents were changed every 3 months. A kidney ureter bladder (KUB) film showed left encrustation along the ureteral stent thus necessitating removal; however, the ureteral stent could not be removed cystoscopically. The ureteral stent was, therefore, extracted using flexible ureteroscopy (URS) with a holmium (Ho): yttrium aluminum garnet (YAG) laser.