Rapid Determination of Aesculin, Aesculetin and Fraxetin in Cortex Fraxini Extract Solutions Based on Ultraviolet Spectroscopy

To evaluate the application of ultraviolet spectroscopy for the rapid determination of aesculin, aesculetin and fraxetin in Cortex fraxini extract solutions, ultraviolet spectra of Cortex fraxini extract solutions from different batches were collected in the spectral range from 200 nm to 400 nm. The...

Full description

Saved in:
Bibliographic Details
Main Authors: Ming Yang, Jia-Lei Chen, Xiu-Feng Shi, Hui-Jue Niu
Format: Article
Language:English
Published: Wiley 2011-01-01
Series:E-Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2011/294298
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832558682057998336
author Ming Yang
Jia-Lei Chen
Xiu-Feng Shi
Hui-Jue Niu
author_facet Ming Yang
Jia-Lei Chen
Xiu-Feng Shi
Hui-Jue Niu
author_sort Ming Yang
collection DOAJ
description To evaluate the application of ultraviolet spectroscopy for the rapid determination of aesculin, aesculetin and fraxetin in Cortex fraxini extract solutions, ultraviolet spectra of Cortex fraxini extract solutions from different batches were collected in the spectral range from 200 nm to 400 nm. The relationship between ultraviolet spectra and chemical parameters displayed some non-linear characteristics. Thus, K-OPLS was proposed to establish the calibration models for the determination of Cortex fraxini extract solutions between the reference data and ultraviolet spectra. The calibration results were achieved for the determination of Cortex fraxini extract solutions. The coefficients of determination in calibration (R2) for aesculin, aesculetin and fraxetin were 0.989, 0.957 and 0.939, while in prediction (R2) were 0.982, 0.979 and 0.962, respectively. And the root-mean-square error of prediction (RMSEP) for aesculin, aesculet and fraxetin were 11.99, 3.02 and 1.59 μg/mL. The results demonstrated that ultraviolet spectroscopy could be used for the rapid determination of these three components in Cortex fraxini extract solutions.
format Article
id doaj-art-b6480ce7589f4ce5a4db097a0f511c31
institution Kabale University
issn 0973-4945
2090-9810
language English
publishDate 2011-01-01
publisher Wiley
record_format Article
series E-Journal of Chemistry
spelling doaj-art-b6480ce7589f4ce5a4db097a0f511c312025-02-03T01:31:51ZengWileyE-Journal of Chemistry0973-49452090-98102011-01-018S1S225S23610.1155/2011/294298Rapid Determination of Aesculin, Aesculetin and Fraxetin in Cortex Fraxini Extract Solutions Based on Ultraviolet SpectroscopyMing Yang0Jia-Lei Chen1Xiu-Feng Shi2Hui-Jue Niu3Medicament Department, Longhua Hospital Affiliated to Shanghai Univesity of TCM Shanghai, ChinaMedicament Department, Longhua Hospital Affiliated to Shanghai Univesity of TCM Shanghai, ChinaMedicament Department, Longhua Hospital Affiliated to Shanghai Univesity of TCM Shanghai, ChinaMedicament Department, Longhua Hospital Affiliated to Shanghai Univesity of TCM Shanghai, ChinaTo evaluate the application of ultraviolet spectroscopy for the rapid determination of aesculin, aesculetin and fraxetin in Cortex fraxini extract solutions, ultraviolet spectra of Cortex fraxini extract solutions from different batches were collected in the spectral range from 200 nm to 400 nm. The relationship between ultraviolet spectra and chemical parameters displayed some non-linear characteristics. Thus, K-OPLS was proposed to establish the calibration models for the determination of Cortex fraxini extract solutions between the reference data and ultraviolet spectra. The calibration results were achieved for the determination of Cortex fraxini extract solutions. The coefficients of determination in calibration (R2) for aesculin, aesculetin and fraxetin were 0.989, 0.957 and 0.939, while in prediction (R2) were 0.982, 0.979 and 0.962, respectively. And the root-mean-square error of prediction (RMSEP) for aesculin, aesculet and fraxetin were 11.99, 3.02 and 1.59 μg/mL. The results demonstrated that ultraviolet spectroscopy could be used for the rapid determination of these three components in Cortex fraxini extract solutions.http://dx.doi.org/10.1155/2011/294298
spellingShingle Ming Yang
Jia-Lei Chen
Xiu-Feng Shi
Hui-Jue Niu
Rapid Determination of Aesculin, Aesculetin and Fraxetin in Cortex Fraxini Extract Solutions Based on Ultraviolet Spectroscopy
E-Journal of Chemistry
title Rapid Determination of Aesculin, Aesculetin and Fraxetin in Cortex Fraxini Extract Solutions Based on Ultraviolet Spectroscopy
title_full Rapid Determination of Aesculin, Aesculetin and Fraxetin in Cortex Fraxini Extract Solutions Based on Ultraviolet Spectroscopy
title_fullStr Rapid Determination of Aesculin, Aesculetin and Fraxetin in Cortex Fraxini Extract Solutions Based on Ultraviolet Spectroscopy
title_full_unstemmed Rapid Determination of Aesculin, Aesculetin and Fraxetin in Cortex Fraxini Extract Solutions Based on Ultraviolet Spectroscopy
title_short Rapid Determination of Aesculin, Aesculetin and Fraxetin in Cortex Fraxini Extract Solutions Based on Ultraviolet Spectroscopy
title_sort rapid determination of aesculin aesculetin and fraxetin in cortex fraxini extract solutions based on ultraviolet spectroscopy
url http://dx.doi.org/10.1155/2011/294298
work_keys_str_mv AT mingyang rapiddeterminationofaesculinaesculetinandfraxetinincortexfraxiniextractsolutionsbasedonultravioletspectroscopy
AT jialeichen rapiddeterminationofaesculinaesculetinandfraxetinincortexfraxiniextractsolutionsbasedonultravioletspectroscopy
AT xiufengshi rapiddeterminationofaesculinaesculetinandfraxetinincortexfraxiniextractsolutionsbasedonultravioletspectroscopy
AT huijueniu rapiddeterminationofaesculinaesculetinandfraxetinincortexfraxiniextractsolutionsbasedonultravioletspectroscopy