Comparative Study of Multiple High-Signal-Intensity Spots on 3D and 2D Magnetic Resonance Sialography for Patients with Sjögren’s Syndrome

We investigated the sensitivities of 2-dimensional (2D) magnetic resonance sialography (MR-S) and unilateral sagittal and axial 3-dimensional (3D) MR-S using a surface coil and their combination in diagnosing patients with Sjögren’s syndrome (SS). We retrospectively analyzed the 3D and 2D MR-S resul...

Full description

Saved in:
Bibliographic Details
Main Authors: Yusuke Shimada, Ikuho Kojima, Masahiro Iikubo
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Radiology Research and Practice
Online Access:http://dx.doi.org/10.1155/2021/5846637
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832563239937900544
author Yusuke Shimada
Ikuho Kojima
Masahiro Iikubo
author_facet Yusuke Shimada
Ikuho Kojima
Masahiro Iikubo
author_sort Yusuke Shimada
collection DOAJ
description We investigated the sensitivities of 2-dimensional (2D) magnetic resonance sialography (MR-S) and unilateral sagittal and axial 3-dimensional (3D) MR-S using a surface coil and their combination in diagnosing patients with Sjögren’s syndrome (SS). We retrospectively analyzed the 3D and 2D MR-S results of 78 patients with SS. We evaluated the sensitivities of multiple high-signal-intensity spots and staging on MR sialograms and analyzed the efficient imaging methods and cross section for diagnosing patients with SS. The sensitivities of MR-S for detecting abnormal findings (i.e., MR-S stage 1 or higher) were as follows: 65 cases (83.3% [95% confidence interval (CI): 73.2–90.8]) for unilateral sagittal 3D MR-S; 62 cases (79.4% [95% CI: 68.8–87.8]) for axial 3D MR-S; 66 cases (84.6% [95% CI: 74.7–91.8]) for combined unilateral sagittal and axial 3D MR-S; and 32 cases (41.0% [95% CI: 30.0–52.7]) for bilateral sagittal 2D MR-S. The ratio of the abnormal finding of MR-S was tested using the two-tailed Fisher’s exact test. Unilateral sagittal, axial, and combined unilateral sagittal and axial 3D MR-S showed significantly higher sensitivity than bilateral sagittal 2D MR-S, respectively (P < 0.001). Most cases upstaged by 3D MR-S were those positive (stage 1 or higher) among the stage 0 cases detected by 2D MR-S. Axial 3D MR-S, compared with 2D MR-S, understaged four cases, which was due to the imaging range of the axial 3D MR-S. We concluded that a single unilateral sagittal 3D MR-S was sufficient and axial 3D MR-S was unnecessary for SS staging. T1- and T2-weighted images are essential for investigating the salivary glands in patients with SS. Therefore, we also concluded that bilateral sagittal 3D MR-S of the parotid glands in addition to T1- and T2-weighted imaging is necessary, sufficient, and most efficient for precise MR imaging examination of the salivary glands, including diagnosing SS.
format Article
id doaj-art-b5dfd9bf6c614cacacfe8c1ba0ded300
institution Kabale University
issn 2090-195X
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series Radiology Research and Practice
spelling doaj-art-b5dfd9bf6c614cacacfe8c1ba0ded3002025-02-03T01:20:39ZengWileyRadiology Research and Practice2090-195X2021-01-01202110.1155/2021/5846637Comparative Study of Multiple High-Signal-Intensity Spots on 3D and 2D Magnetic Resonance Sialography for Patients with Sjögren’s SyndromeYusuke Shimada0Ikuho Kojima1Masahiro Iikubo2Department of Dental Informatics and RadiologyDepartment of Dental Informatics and RadiologyDepartment of Dental Informatics and RadiologyWe investigated the sensitivities of 2-dimensional (2D) magnetic resonance sialography (MR-S) and unilateral sagittal and axial 3-dimensional (3D) MR-S using a surface coil and their combination in diagnosing patients with Sjögren’s syndrome (SS). We retrospectively analyzed the 3D and 2D MR-S results of 78 patients with SS. We evaluated the sensitivities of multiple high-signal-intensity spots and staging on MR sialograms and analyzed the efficient imaging methods and cross section for diagnosing patients with SS. The sensitivities of MR-S for detecting abnormal findings (i.e., MR-S stage 1 or higher) were as follows: 65 cases (83.3% [95% confidence interval (CI): 73.2–90.8]) for unilateral sagittal 3D MR-S; 62 cases (79.4% [95% CI: 68.8–87.8]) for axial 3D MR-S; 66 cases (84.6% [95% CI: 74.7–91.8]) for combined unilateral sagittal and axial 3D MR-S; and 32 cases (41.0% [95% CI: 30.0–52.7]) for bilateral sagittal 2D MR-S. The ratio of the abnormal finding of MR-S was tested using the two-tailed Fisher’s exact test. Unilateral sagittal, axial, and combined unilateral sagittal and axial 3D MR-S showed significantly higher sensitivity than bilateral sagittal 2D MR-S, respectively (P < 0.001). Most cases upstaged by 3D MR-S were those positive (stage 1 or higher) among the stage 0 cases detected by 2D MR-S. Axial 3D MR-S, compared with 2D MR-S, understaged four cases, which was due to the imaging range of the axial 3D MR-S. We concluded that a single unilateral sagittal 3D MR-S was sufficient and axial 3D MR-S was unnecessary for SS staging. T1- and T2-weighted images are essential for investigating the salivary glands in patients with SS. Therefore, we also concluded that bilateral sagittal 3D MR-S of the parotid glands in addition to T1- and T2-weighted imaging is necessary, sufficient, and most efficient for precise MR imaging examination of the salivary glands, including diagnosing SS.http://dx.doi.org/10.1155/2021/5846637
spellingShingle Yusuke Shimada
Ikuho Kojima
Masahiro Iikubo
Comparative Study of Multiple High-Signal-Intensity Spots on 3D and 2D Magnetic Resonance Sialography for Patients with Sjögren’s Syndrome
Radiology Research and Practice
title Comparative Study of Multiple High-Signal-Intensity Spots on 3D and 2D Magnetic Resonance Sialography for Patients with Sjögren’s Syndrome
title_full Comparative Study of Multiple High-Signal-Intensity Spots on 3D and 2D Magnetic Resonance Sialography for Patients with Sjögren’s Syndrome
title_fullStr Comparative Study of Multiple High-Signal-Intensity Spots on 3D and 2D Magnetic Resonance Sialography for Patients with Sjögren’s Syndrome
title_full_unstemmed Comparative Study of Multiple High-Signal-Intensity Spots on 3D and 2D Magnetic Resonance Sialography for Patients with Sjögren’s Syndrome
title_short Comparative Study of Multiple High-Signal-Intensity Spots on 3D and 2D Magnetic Resonance Sialography for Patients with Sjögren’s Syndrome
title_sort comparative study of multiple high signal intensity spots on 3d and 2d magnetic resonance sialography for patients with sjogren s syndrome
url http://dx.doi.org/10.1155/2021/5846637
work_keys_str_mv AT yusukeshimada comparativestudyofmultiplehighsignalintensityspotson3dand2dmagneticresonancesialographyforpatientswithsjogrenssyndrome
AT ikuhokojima comparativestudyofmultiplehighsignalintensityspotson3dand2dmagneticresonancesialographyforpatientswithsjogrenssyndrome
AT masahiroiikubo comparativestudyofmultiplehighsignalintensityspotson3dand2dmagneticresonancesialographyforpatientswithsjogrenssyndrome