CFD Analysis on the Performance of Twisted Tapes in Horizontal Heat Exchangers for Shower Water Heat Recovery

The thermal energy found in shower hot wastewater, which is usually dumped, can be recovered through heat exchangers and used to pre-heat shower cold-water, contributing to energy sustainability. The objective and novelty of this work are to present a computational fluid dynamics (CFD) model and a t...

Full description

Saved in:
Bibliographic Details
Main Authors: Eduardo Silva, Vitor Ferreira, José Cunha, Eliseu Monteiro
Format: Article
Language:English
Published: Semnan University 2025-05-01
Series:Journal of Heat and Mass Transfer Research
Subjects:
Online Access:https://jhmtr.semnan.ac.ir/article_9143_a135b94309c212e6e112dae0063494c0.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832593565598875648
author Eduardo Silva
Vitor Ferreira
José Cunha
Eliseu Monteiro
author_facet Eduardo Silva
Vitor Ferreira
José Cunha
Eliseu Monteiro
author_sort Eduardo Silva
collection DOAJ
description The thermal energy found in shower hot wastewater, which is usually dumped, can be recovered through heat exchangers and used to pre-heat shower cold-water, contributing to energy sustainability. The objective and novelty of this work are to present a computational fluid dynamics (CFD) model and a theoretical model based on literature correlations to evaluate the performance of a shower water horizontal heat exchanger with twisted tape inserts. CFD simulations are used to improve the shape of twisted tape in the setting of the turbulator. The findings suggest that the wastewater flow convection heat transfer coefficient is between the flow around a cylinder and the flow around a cylinder in a narrow channel. The results for the turbulator are consistent with theoretical data, except for twist ratios below 3. The most promising twisted tape design has a twist ratio of 4 and a thickness of 1 mm. A conclusion could be drawn that the efficacy of the twisted tape in the heat exchanger is greater at lower flow rates. The performance gain ranges from 18.1 % to 3.0 % for flow rates of 3–10 L/min. Future directions for this research should focus on the improvement of the external convection coefficient because it represents the highest thermal resistance in the shower wastewater horizontal heat exchanger.
format Article
id doaj-art-b1658d97d761497f86da68c5f4928c47
institution Kabale University
issn 2345-508X
2383-3068
language English
publishDate 2025-05-01
publisher Semnan University
record_format Article
series Journal of Heat and Mass Transfer Research
spelling doaj-art-b1658d97d761497f86da68c5f4928c472025-01-20T11:28:50ZengSemnan UniversityJournal of Heat and Mass Transfer Research2345-508X2383-30682025-05-0112113715010.22075/jhmtr.2024.35215.16049143CFD Analysis on the Performance of Twisted Tapes in Horizontal Heat Exchangers for Shower Water Heat RecoveryEduardo Silva0Vitor Ferreira1José Cunha2Eliseu Monteiro3Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, PortugalLAETA-INEGI, Associated Laboratory for Energy, Transports and Aeronautics- Institute of Science and Innovation in Mechanical and Industrial Engineering, Rua Dr. Roberto Frias, 4200-465 Porto, PortugalLAETA-INEGI, Associated Laboratory for Energy, Transports and Aeronautics- Institute of Science and Innovation in Mechanical and Industrial Engineering, Rua Dr. Roberto Frias, 4200-465 Porto, PortugalFaculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, PortugalThe thermal energy found in shower hot wastewater, which is usually dumped, can be recovered through heat exchangers and used to pre-heat shower cold-water, contributing to energy sustainability. The objective and novelty of this work are to present a computational fluid dynamics (CFD) model and a theoretical model based on literature correlations to evaluate the performance of a shower water horizontal heat exchanger with twisted tape inserts. CFD simulations are used to improve the shape of twisted tape in the setting of the turbulator. The findings suggest that the wastewater flow convection heat transfer coefficient is between the flow around a cylinder and the flow around a cylinder in a narrow channel. The results for the turbulator are consistent with theoretical data, except for twist ratios below 3. The most promising twisted tape design has a twist ratio of 4 and a thickness of 1 mm. A conclusion could be drawn that the efficacy of the twisted tape in the heat exchanger is greater at lower flow rates. The performance gain ranges from 18.1 % to 3.0 % for flow rates of 3–10 L/min. Future directions for this research should focus on the improvement of the external convection coefficient because it represents the highest thermal resistance in the shower wastewater horizontal heat exchanger.https://jhmtr.semnan.ac.ir/article_9143_a135b94309c212e6e112dae0063494c0.pdfcomputational fluid dynamicsconvectionenergy sustainabilitywastewater heat exchangertwisted tape
spellingShingle Eduardo Silva
Vitor Ferreira
José Cunha
Eliseu Monteiro
CFD Analysis on the Performance of Twisted Tapes in Horizontal Heat Exchangers for Shower Water Heat Recovery
Journal of Heat and Mass Transfer Research
computational fluid dynamics
convection
energy sustainability
wastewater heat exchanger
twisted tape
title CFD Analysis on the Performance of Twisted Tapes in Horizontal Heat Exchangers for Shower Water Heat Recovery
title_full CFD Analysis on the Performance of Twisted Tapes in Horizontal Heat Exchangers for Shower Water Heat Recovery
title_fullStr CFD Analysis on the Performance of Twisted Tapes in Horizontal Heat Exchangers for Shower Water Heat Recovery
title_full_unstemmed CFD Analysis on the Performance of Twisted Tapes in Horizontal Heat Exchangers for Shower Water Heat Recovery
title_short CFD Analysis on the Performance of Twisted Tapes in Horizontal Heat Exchangers for Shower Water Heat Recovery
title_sort cfd analysis on the performance of twisted tapes in horizontal heat exchangers for shower water heat recovery
topic computational fluid dynamics
convection
energy sustainability
wastewater heat exchanger
twisted tape
url https://jhmtr.semnan.ac.ir/article_9143_a135b94309c212e6e112dae0063494c0.pdf
work_keys_str_mv AT eduardosilva cfdanalysisontheperformanceoftwistedtapesinhorizontalheatexchangersforshowerwaterheatrecovery
AT vitorferreira cfdanalysisontheperformanceoftwistedtapesinhorizontalheatexchangersforshowerwaterheatrecovery
AT josecunha cfdanalysisontheperformanceoftwistedtapesinhorizontalheatexchangersforshowerwaterheatrecovery
AT eliseumonteiro cfdanalysisontheperformanceoftwistedtapesinhorizontalheatexchangersforshowerwaterheatrecovery