Heat Flux at the Surface of Metal Foil Heater under Evaporating Sessile Droplets
Evaporating water drops on a horizontal heated substrate were investigated experimentally. The heater was made of a constantan foil with the thickness of 25 μm and size of 42 × 35 mm2. The temperature of the bottom foil surface was measured by the infrared (IR) camera. To determine the heat flux den...
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2015-01-01
|
| Series: | International Journal of Aerospace Engineering |
| Online Access: | http://dx.doi.org/10.1155/2015/391036 |