Heat Flux at the Surface of Metal Foil Heater under Evaporating Sessile Droplets

Evaporating water drops on a horizontal heated substrate were investigated experimentally. The heater was made of a constantan foil with the thickness of 25 μm and size of 42 × 35 mm2. The temperature of the bottom foil surface was measured by the infrared (IR) camera. To determine the heat flux den...

Full description

Saved in:
Bibliographic Details
Main Authors: Igor Marchuk, Andrey Karchevsky, Anton Surtaev, Oleg Kabov
Format: Article
Language:English
Published: Wiley 2015-01-01
Series:International Journal of Aerospace Engineering
Online Access:http://dx.doi.org/10.1155/2015/391036