Diagnostic Accuracy Of Spectral Doppler Ultrasound In Diagnosis Of Malignant Breast Lesions Taking Histopathology As Gold Standard
Objective: To determine the diagnostic accuracy of Spectral Doppler Ultrasound in malignant breast lesions, taking histopathology as the gold standard. Place and Duration of Study: This study was conducted at the Department of Diagnostic Radiology, Pak Emirates Military Hospital, Rawalpindi. The...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Rawalpindi Medical University
2024-09-01
|
Series: | Journal of Rawalpindi Medical College |
Online Access: | https://www.journalrmc.com/index.php/JRMC/article/view/2345 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832086968907857920 |
---|---|
author | Mehwish Tabassum Rabia Waseem Manal Niazi Zainab Riaz Hamna Shakil Wajeeha Anam |
author_facet | Mehwish Tabassum Rabia Waseem Manal Niazi Zainab Riaz Hamna Shakil Wajeeha Anam |
author_sort | Mehwish Tabassum |
collection | DOAJ |
description |
Objective: To determine the diagnostic accuracy of Spectral Doppler Ultrasound in malignant breast lesions, taking histopathology as the gold standard.
Place and Duration of Study: This study was conducted at the Department of Diagnostic Radiology, Pak Emirates Military Hospital, Rawalpindi. The study duration was 06 months from 10th June 2020 to 10th December 2020.
Methods: The study design was Cross-sectional.Consecutive non-probability sampling technique was used for sample collection. A total of 165 women with breast lumps with a duration of lump >1 month and of any size and age 25-65 years were enrolled. Each patient was subject to spectral Doppler ultrasound using a high-resolution unit with a linear array probe centred at 7.5MHz. The findings were interpreted by a consultant radiologist for the presence or absence of malignant breast lesions. All patients underwent biopsy in the concerned ward and the histopathology report was compared with spectral Doppler USG findings.
Results: Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of Spectral Doppler Ultrasound in diagnosing malignant breast lesions, taking histopathology as gold standard was 91.84%, 83.86%, 89.11%, 87.50% and 88.48% respectively. All spectral Doppler indices, including mean peak systolic velocity (PSV), resistive index (RI), and Pulsatility index (PI) were significantly higher in malignant tumours. The optimal cut-off points were PSV = 12.5 cm/s (sensitivity: 85%, specificity: 82%), RI = 0.68 (sensitivity = 92%, specificity = 85%), and PI = 0.93 (sensitivity = 91%, specificity = 88%).
Conclusion: The use of Doppler Ultrasound is a feasible, safer and non-invasive modality and has high sensitivity and specificity in the diagnosis of malignant breast lesions.
|
format | Article |
id | doaj-art-a6c1e2a61ac64a68bfc57eb37eb63dff |
institution | Kabale University |
issn | 1683-3562 1683-3570 |
language | English |
publishDate | 2024-09-01 |
publisher | Rawalpindi Medical University |
record_format | Article |
series | Journal of Rawalpindi Medical College |
spelling | doaj-art-a6c1e2a61ac64a68bfc57eb37eb63dff2025-02-06T08:35:59ZengRawalpindi Medical UniversityJournal of Rawalpindi Medical College1683-35621683-35702024-09-0128310.37939/jrmc.v28i3.2345Diagnostic Accuracy Of Spectral Doppler Ultrasound In Diagnosis Of Malignant Breast Lesions Taking Histopathology As Gold StandardMehwish Tabassum0Rabia Waseem1Manal Niazi2Zainab Riaz3Hamna Shakil4Wajeeha Anam5Dr Akbar Niazi Teaching HospitalHITEC,IMSIMDC, ANTHAli Medical Center, Islamabad IMDC, ANTHIMDC, ANTH Objective: To determine the diagnostic accuracy of Spectral Doppler Ultrasound in malignant breast lesions, taking histopathology as the gold standard. Place and Duration of Study: This study was conducted at the Department of Diagnostic Radiology, Pak Emirates Military Hospital, Rawalpindi. The study duration was 06 months from 10th June 2020 to 10th December 2020. Methods: The study design was Cross-sectional.Consecutive non-probability sampling technique was used for sample collection. A total of 165 women with breast lumps with a duration of lump >1 month and of any size and age 25-65 years were enrolled. Each patient was subject to spectral Doppler ultrasound using a high-resolution unit with a linear array probe centred at 7.5MHz. The findings were interpreted by a consultant radiologist for the presence or absence of malignant breast lesions. All patients underwent biopsy in the concerned ward and the histopathology report was compared with spectral Doppler USG findings. Results: Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of Spectral Doppler Ultrasound in diagnosing malignant breast lesions, taking histopathology as gold standard was 91.84%, 83.86%, 89.11%, 87.50% and 88.48% respectively. All spectral Doppler indices, including mean peak systolic velocity (PSV), resistive index (RI), and Pulsatility index (PI) were significantly higher in malignant tumours. The optimal cut-off points were PSV = 12.5 cm/s (sensitivity: 85%, specificity: 82%), RI = 0.68 (sensitivity = 92%, specificity = 85%), and PI = 0.93 (sensitivity = 91%, specificity = 88%). Conclusion: The use of Doppler Ultrasound is a feasible, safer and non-invasive modality and has high sensitivity and specificity in the diagnosis of malignant breast lesions. https://www.journalrmc.com/index.php/JRMC/article/view/2345 |
spellingShingle | Mehwish Tabassum Rabia Waseem Manal Niazi Zainab Riaz Hamna Shakil Wajeeha Anam Diagnostic Accuracy Of Spectral Doppler Ultrasound In Diagnosis Of Malignant Breast Lesions Taking Histopathology As Gold Standard Journal of Rawalpindi Medical College |
title | Diagnostic Accuracy Of Spectral Doppler Ultrasound In Diagnosis Of Malignant Breast Lesions Taking Histopathology As Gold Standard |
title_full | Diagnostic Accuracy Of Spectral Doppler Ultrasound In Diagnosis Of Malignant Breast Lesions Taking Histopathology As Gold Standard |
title_fullStr | Diagnostic Accuracy Of Spectral Doppler Ultrasound In Diagnosis Of Malignant Breast Lesions Taking Histopathology As Gold Standard |
title_full_unstemmed | Diagnostic Accuracy Of Spectral Doppler Ultrasound In Diagnosis Of Malignant Breast Lesions Taking Histopathology As Gold Standard |
title_short | Diagnostic Accuracy Of Spectral Doppler Ultrasound In Diagnosis Of Malignant Breast Lesions Taking Histopathology As Gold Standard |
title_sort | diagnostic accuracy of spectral doppler ultrasound in diagnosis of malignant breast lesions taking histopathology as gold standard |
url | https://www.journalrmc.com/index.php/JRMC/article/view/2345 |
work_keys_str_mv | AT mehwishtabassum diagnosticaccuracyofspectraldopplerultrasoundindiagnosisofmalignantbreastlesionstakinghistopathologyasgoldstandard AT rabiawaseem diagnosticaccuracyofspectraldopplerultrasoundindiagnosisofmalignantbreastlesionstakinghistopathologyasgoldstandard AT manalniazi diagnosticaccuracyofspectraldopplerultrasoundindiagnosisofmalignantbreastlesionstakinghistopathologyasgoldstandard AT zainabriaz diagnosticaccuracyofspectraldopplerultrasoundindiagnosisofmalignantbreastlesionstakinghistopathologyasgoldstandard AT hamnashakil diagnosticaccuracyofspectraldopplerultrasoundindiagnosisofmalignantbreastlesionstakinghistopathologyasgoldstandard AT wajeehaanam diagnosticaccuracyofspectraldopplerultrasoundindiagnosisofmalignantbreastlesionstakinghistopathologyasgoldstandard |