Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy
In order to improve the predictive accuracy of human blood glucose quantitative analysis model with fourier transform infrared (FT-IR) spectroscopy, this paper uses a method named improved extended multiplicative scatter correction (Im-EMSC), which can effectively eliminate the scattering effects ca...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2013-01-01
|
Series: | Journal of Spectroscopy |
Online Access: | http://dx.doi.org/10.1155/2013/916351 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832556008648474624 |
---|---|
author | Qingbo Li Qishuo Gao Guangjun Zhang |
author_facet | Qingbo Li Qishuo Gao Guangjun Zhang |
author_sort | Qingbo Li |
collection | DOAJ |
description | In order to improve the predictive accuracy of human blood glucose quantitative analysis model with fourier transform infrared (FT-IR) spectroscopy, this paper uses a method named improved extended multiplicative scatter correction (Im-EMSC), which can effectively eliminate the scattering effects caused by human body strong scattering. The principal components of the differential spectra are used instead of the pure spectra of the analytes in this algorithm. Calibrate the unwanted physical characteristic through the shape of the curve of principal components, and extract the original glucose concentration information. Im-EMSC can efficiently remove most of the pathlength difference and baseline shift influences. Firstly, Im-EMSC is used as a preprocessing method, and then partial least squares (PLS) regression method is adopted to establish a quantitative analysis model. In this paper, the result of Im-EMSC is compared with those popular scattering correction algorithms of multiplicative scatter correction (MSC) and extended multiplicative scatter correction (EMSC) preprocessing methods. Experimental results show that the prediction accuracy has been greatly improved with Im-EMSC method, which is helpful for human noninvasive glucose concentration detection technology. |
format | Article |
id | doaj-art-a03b2c9ea19e4759b3409b2a912dff8d |
institution | Kabale University |
issn | 2314-4920 2314-4939 |
language | English |
publishDate | 2013-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Spectroscopy |
spelling | doaj-art-a03b2c9ea19e4759b3409b2a912dff8d2025-02-03T05:46:40ZengWileyJournal of Spectroscopy2314-49202314-49392013-01-01201310.1155/2013/916351916351Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR SpectroscopyQingbo Li0Qishuo Gao1Guangjun Zhang2School of Instrumentation Science and Optoelectronics Engineering, Precision Optomechatronics Technology Key Laboratory of Education Ministry, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, ChinaSchool of Instrumentation Science and Optoelectronics Engineering, Precision Optomechatronics Technology Key Laboratory of Education Ministry, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, ChinaSchool of Instrumentation Science and Optoelectronics Engineering, Precision Optomechatronics Technology Key Laboratory of Education Ministry, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, ChinaIn order to improve the predictive accuracy of human blood glucose quantitative analysis model with fourier transform infrared (FT-IR) spectroscopy, this paper uses a method named improved extended multiplicative scatter correction (Im-EMSC), which can effectively eliminate the scattering effects caused by human body strong scattering. The principal components of the differential spectra are used instead of the pure spectra of the analytes in this algorithm. Calibrate the unwanted physical characteristic through the shape of the curve of principal components, and extract the original glucose concentration information. Im-EMSC can efficiently remove most of the pathlength difference and baseline shift influences. Firstly, Im-EMSC is used as a preprocessing method, and then partial least squares (PLS) regression method is adopted to establish a quantitative analysis model. In this paper, the result of Im-EMSC is compared with those popular scattering correction algorithms of multiplicative scatter correction (MSC) and extended multiplicative scatter correction (EMSC) preprocessing methods. Experimental results show that the prediction accuracy has been greatly improved with Im-EMSC method, which is helpful for human noninvasive glucose concentration detection technology.http://dx.doi.org/10.1155/2013/916351 |
spellingShingle | Qingbo Li Qishuo Gao Guangjun Zhang Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy Journal of Spectroscopy |
title | Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy |
title_full | Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy |
title_fullStr | Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy |
title_full_unstemmed | Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy |
title_short | Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy |
title_sort | improved extended multiplicative scatter correction algorithm applied in blood glucose noninvasive measurement with ft ir spectroscopy |
url | http://dx.doi.org/10.1155/2013/916351 |
work_keys_str_mv | AT qingboli improvedextendedmultiplicativescattercorrectionalgorithmappliedinbloodglucosenoninvasivemeasurementwithftirspectroscopy AT qishuogao improvedextendedmultiplicativescattercorrectionalgorithmappliedinbloodglucosenoninvasivemeasurementwithftirspectroscopy AT guangjunzhang improvedextendedmultiplicativescattercorrectionalgorithmappliedinbloodglucosenoninvasivemeasurementwithftirspectroscopy |