Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy

In order to improve the predictive accuracy of human blood glucose quantitative analysis model with fourier transform infrared (FT-IR) spectroscopy, this paper uses a method named improved extended multiplicative scatter correction (Im-EMSC), which can effectively eliminate the scattering effects ca...

Full description

Saved in:
Bibliographic Details
Main Authors: Qingbo Li, Qishuo Gao, Guangjun Zhang
Format: Article
Language:English
Published: Wiley 2013-01-01
Series:Journal of Spectroscopy
Online Access:http://dx.doi.org/10.1155/2013/916351
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832556008648474624
author Qingbo Li
Qishuo Gao
Guangjun Zhang
author_facet Qingbo Li
Qishuo Gao
Guangjun Zhang
author_sort Qingbo Li
collection DOAJ
description In order to improve the predictive accuracy of human blood glucose quantitative analysis model with fourier transform infrared (FT-IR) spectroscopy, this paper uses a method named improved extended multiplicative scatter correction (Im-EMSC), which can effectively eliminate the scattering effects caused by human body strong scattering. The principal components of the differential spectra are used instead of the pure spectra of the analytes in this algorithm. Calibrate the unwanted physical characteristic through the shape of the curve of principal components, and extract the original glucose concentration information. Im-EMSC can efficiently remove most of the pathlength difference and baseline shift influences. Firstly, Im-EMSC is used as a preprocessing method, and then partial least squares (PLS) regression method is adopted to establish a quantitative analysis model. In this paper, the result of Im-EMSC is compared with those popular scattering correction algorithms of multiplicative scatter correction (MSC) and extended multiplicative scatter correction (EMSC) preprocessing methods. Experimental results show that the prediction accuracy has been greatly improved with Im-EMSC method, which is helpful for human noninvasive glucose concentration detection technology.
format Article
id doaj-art-a03b2c9ea19e4759b3409b2a912dff8d
institution Kabale University
issn 2314-4920
2314-4939
language English
publishDate 2013-01-01
publisher Wiley
record_format Article
series Journal of Spectroscopy
spelling doaj-art-a03b2c9ea19e4759b3409b2a912dff8d2025-02-03T05:46:40ZengWileyJournal of Spectroscopy2314-49202314-49392013-01-01201310.1155/2013/916351916351Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR SpectroscopyQingbo Li0Qishuo Gao1Guangjun Zhang2School of Instrumentation Science and Optoelectronics Engineering, Precision Optomechatronics Technology Key Laboratory of Education Ministry, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, ChinaSchool of Instrumentation Science and Optoelectronics Engineering, Precision Optomechatronics Technology Key Laboratory of Education Ministry, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, ChinaSchool of Instrumentation Science and Optoelectronics Engineering, Precision Optomechatronics Technology Key Laboratory of Education Ministry, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, ChinaIn order to improve the predictive accuracy of human blood glucose quantitative analysis model with fourier transform infrared (FT-IR) spectroscopy, this paper uses a method named improved extended multiplicative scatter correction (Im-EMSC), which can effectively eliminate the scattering effects caused by human body strong scattering. The principal components of the differential spectra are used instead of the pure spectra of the analytes in this algorithm. Calibrate the unwanted physical characteristic through the shape of the curve of principal components, and extract the original glucose concentration information. Im-EMSC can efficiently remove most of the pathlength difference and baseline shift influences. Firstly, Im-EMSC is used as a preprocessing method, and then partial least squares (PLS) regression method is adopted to establish a quantitative analysis model. In this paper, the result of Im-EMSC is compared with those popular scattering correction algorithms of multiplicative scatter correction (MSC) and extended multiplicative scatter correction (EMSC) preprocessing methods. Experimental results show that the prediction accuracy has been greatly improved with Im-EMSC method, which is helpful for human noninvasive glucose concentration detection technology.http://dx.doi.org/10.1155/2013/916351
spellingShingle Qingbo Li
Qishuo Gao
Guangjun Zhang
Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy
Journal of Spectroscopy
title Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy
title_full Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy
title_fullStr Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy
title_full_unstemmed Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy
title_short Improved Extended Multiplicative Scatter Correction Algorithm Applied in Blood Glucose Noninvasive Measurement with FT-IR Spectroscopy
title_sort improved extended multiplicative scatter correction algorithm applied in blood glucose noninvasive measurement with ft ir spectroscopy
url http://dx.doi.org/10.1155/2013/916351
work_keys_str_mv AT qingboli improvedextendedmultiplicativescattercorrectionalgorithmappliedinbloodglucosenoninvasivemeasurementwithftirspectroscopy
AT qishuogao improvedextendedmultiplicativescattercorrectionalgorithmappliedinbloodglucosenoninvasivemeasurementwithftirspectroscopy
AT guangjunzhang improvedextendedmultiplicativescattercorrectionalgorithmappliedinbloodglucosenoninvasivemeasurementwithftirspectroscopy