Association of SUDOSCAN Values with Vibration Perception Threshold in Chinese Patients with Type 2 Diabetes Mellitus

Aims/Introduction. SUDOSCAN has been proved to be an efficient method in detecting diabetic microvascular complications. In this study, we determine to detect the possible relationship between vibration perception threshold (VPT) and cardiac autonomic neuropathy (CAN) values produced by SUDOSCAN. Ma...

Full description

Saved in:
Bibliographic Details
Main Authors: Xiaoming Zhu, Fei Mao, Siying Liu, Hangping Zheng, Bin Lu, Yiming Li
Format: Article
Language:English
Published: Wiley 2017-01-01
Series:International Journal of Endocrinology
Online Access:http://dx.doi.org/10.1155/2017/8435252
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832558608508780544
author Xiaoming Zhu
Fei Mao
Siying Liu
Hangping Zheng
Bin Lu
Yiming Li
author_facet Xiaoming Zhu
Fei Mao
Siying Liu
Hangping Zheng
Bin Lu
Yiming Li
author_sort Xiaoming Zhu
collection DOAJ
description Aims/Introduction. SUDOSCAN has been proved to be an efficient method in detecting diabetic microvascular complications. In this study, we determine to detect the possible relationship between vibration perception threshold (VPT) and cardiac autonomic neuropathy (CAN) values produced by SUDOSCAN. Materials and Methods. A total of 920 Chinese patients with T2DM were enrolled in the study. Spearman correlation analysis and multivariate regression analysis were performed to determine the relation between CAN and VPT values. Mean VPT values across the CAN value tertiles were analyzed stratified by HbA1c status. Results. In the study, we discovered a relatively high correlation between CAN value and both VPT values from dorsal feet and toes. Multivariate regression analyses also showed a significant relation between VPT and CAN values after adjusting all covariates. The mean value of VPT decreased across the SUDOSCAN-CAN value quartiles in both groups, and it was higher in patients with HbA1C > 9% than in patients with HbA1C < 9% across all quartiles of the SUDOSCAN-CAN except for the VPT mean in the low quartile of the SUDOSCAN-CAN value. Conclusions. All these results suggested that SUDOSCAN-CAN result was associated with VPT value which indicated a probable link between VPT value and cardiovascular autonomic dysfunction.
format Article
id doaj-art-9a4992e0bbf14f67bec27f395fccbfc3
institution Kabale University
issn 1687-8337
1687-8345
language English
publishDate 2017-01-01
publisher Wiley
record_format Article
series International Journal of Endocrinology
spelling doaj-art-9a4992e0bbf14f67bec27f395fccbfc32025-02-03T01:31:57ZengWileyInternational Journal of Endocrinology1687-83371687-83452017-01-01201710.1155/2017/84352528435252Association of SUDOSCAN Values with Vibration Perception Threshold in Chinese Patients with Type 2 Diabetes MellitusXiaoming Zhu0Fei Mao1Siying Liu2Hangping Zheng3Bin Lu4Yiming Li5Department of Endocrinology and Metabolism, Huashan Hospital, Fudan University, Shanghai, ChinaDepartment of Endocrinology and Metabolism, Huashan Hospital, Fudan University, Shanghai, ChinaDepartment of Endocrinology and Metabolism, Huashan Hospital, Fudan University, Shanghai, ChinaDepartment of Endocrinology and Metabolism, Huashan Hospital, Fudan University, Shanghai, ChinaDepartment of Endocrinology and Metabolism, Huashan Hospital, Fudan University, Shanghai, ChinaDepartment of Endocrinology and Metabolism, Huashan Hospital, Fudan University, Shanghai, ChinaAims/Introduction. SUDOSCAN has been proved to be an efficient method in detecting diabetic microvascular complications. In this study, we determine to detect the possible relationship between vibration perception threshold (VPT) and cardiac autonomic neuropathy (CAN) values produced by SUDOSCAN. Materials and Methods. A total of 920 Chinese patients with T2DM were enrolled in the study. Spearman correlation analysis and multivariate regression analysis were performed to determine the relation between CAN and VPT values. Mean VPT values across the CAN value tertiles were analyzed stratified by HbA1c status. Results. In the study, we discovered a relatively high correlation between CAN value and both VPT values from dorsal feet and toes. Multivariate regression analyses also showed a significant relation between VPT and CAN values after adjusting all covariates. The mean value of VPT decreased across the SUDOSCAN-CAN value quartiles in both groups, and it was higher in patients with HbA1C > 9% than in patients with HbA1C < 9% across all quartiles of the SUDOSCAN-CAN except for the VPT mean in the low quartile of the SUDOSCAN-CAN value. Conclusions. All these results suggested that SUDOSCAN-CAN result was associated with VPT value which indicated a probable link between VPT value and cardiovascular autonomic dysfunction.http://dx.doi.org/10.1155/2017/8435252
spellingShingle Xiaoming Zhu
Fei Mao
Siying Liu
Hangping Zheng
Bin Lu
Yiming Li
Association of SUDOSCAN Values with Vibration Perception Threshold in Chinese Patients with Type 2 Diabetes Mellitus
International Journal of Endocrinology
title Association of SUDOSCAN Values with Vibration Perception Threshold in Chinese Patients with Type 2 Diabetes Mellitus
title_full Association of SUDOSCAN Values with Vibration Perception Threshold in Chinese Patients with Type 2 Diabetes Mellitus
title_fullStr Association of SUDOSCAN Values with Vibration Perception Threshold in Chinese Patients with Type 2 Diabetes Mellitus
title_full_unstemmed Association of SUDOSCAN Values with Vibration Perception Threshold in Chinese Patients with Type 2 Diabetes Mellitus
title_short Association of SUDOSCAN Values with Vibration Perception Threshold in Chinese Patients with Type 2 Diabetes Mellitus
title_sort association of sudoscan values with vibration perception threshold in chinese patients with type 2 diabetes mellitus
url http://dx.doi.org/10.1155/2017/8435252
work_keys_str_mv AT xiaomingzhu associationofsudoscanvalueswithvibrationperceptionthresholdinchinesepatientswithtype2diabetesmellitus
AT feimao associationofsudoscanvalueswithvibrationperceptionthresholdinchinesepatientswithtype2diabetesmellitus
AT siyingliu associationofsudoscanvalueswithvibrationperceptionthresholdinchinesepatientswithtype2diabetesmellitus
AT hangpingzheng associationofsudoscanvalueswithvibrationperceptionthresholdinchinesepatientswithtype2diabetesmellitus
AT binlu associationofsudoscanvalueswithvibrationperceptionthresholdinchinesepatientswithtype2diabetesmellitus
AT yimingli associationofsudoscanvalueswithvibrationperceptionthresholdinchinesepatientswithtype2diabetesmellitus