Determination of minimum secondary winding coils turns for transformer three-phase-multiphase phase number converter

The article has considered an approach to determining the minimum of the secondary winding coils turns of a transformer three-phase-multiphase phase number converter. Each phase of the secondary winding of the considered converter consists of three coils connected in series placed on three diff...

Full description

Saved in:
Bibliographic Details
Main Author: Yu. V. Moskalev
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2022-02-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%201%20(181)%20(%D0%9E%D0%9D%D0%92)/61-66%20%D0%9C%D0%BE%D1%81%D0%BA%D0%B0%D0%BB%D0%B5%D0%B2%20%D0%AE.%20%D0%92..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832570017073332224
author Yu. V. Moskalev
author_facet Yu. V. Moskalev
author_sort Yu. V. Moskalev
collection DOAJ
description The article has considered an approach to determining the minimum of the secondary winding coils turns of a transformer three-phase-multiphase phase number converter. Each phase of the secondary winding of the considered converter consists of three coils connected in series placed on three different rods of the magnetic circuit. In order to solve the optimization problem, the interior-point method is used. As an example, for a three-phase-five-phase converter has determined the minimum number of turns of the secondary winding, the total power consumed by the coils of the secondary winding is calculated. A vector diagram EMF of the coils of the secondary winding is constructed, explaining the formation of a symmetrical five-phase EMF system at the terminals of the secondary winding. Using the proposed approach, it is possible to design a transformer converter of the number of phases with a three-phase primary winding and a multiphase secondary winding, the number of phases of which is more than two.
format Article
id doaj-art-97e2cc9ad3754cccbe1edae2f84ab859
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2022-02-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-97e2cc9ad3754cccbe1edae2f84ab8592025-02-02T18:26:31ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412022-02-011 (181)616610.25206/1813-8225-2022-181-61-66Determination of minimum secondary winding coils turns for transformer three-phase-multiphase phase number converterYu. V. Moskalev0https://orcid.org/0000-0002-0970-937XOmsk State Transport UniversityThe article has considered an approach to determining the minimum of the secondary winding coils turns of a transformer three-phase-multiphase phase number converter. Each phase of the secondary winding of the considered converter consists of three coils connected in series placed on three different rods of the magnetic circuit. In order to solve the optimization problem, the interior-point method is used. As an example, for a three-phase-five-phase converter has determined the minimum number of turns of the secondary winding, the total power consumed by the coils of the secondary winding is calculated. A vector diagram EMF of the coils of the secondary winding is constructed, explaining the formation of a symmetrical five-phase EMF system at the terminals of the secondary winding. Using the proposed approach, it is possible to design a transformer converter of the number of phases with a three-phase primary winding and a multiphase secondary winding, the number of phases of which is more than two.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%201%20(181)%20(%D0%9E%D0%9D%D0%92)/61-66%20%D0%9C%D0%BE%D1%81%D0%BA%D0%B0%D0%BB%D0%B5%D0%B2%20%D0%AE.%20%D0%92..pdftransformer phase convertermultiphase windingoptimization amount of the coils turnsmultiphase symmetric system
spellingShingle Yu. V. Moskalev
Determination of minimum secondary winding coils turns for transformer three-phase-multiphase phase number converter
Омский научный вестник
transformer phase converter
multiphase winding
optimization amount of the coils turns
multiphase symmetric system
title Determination of minimum secondary winding coils turns for transformer three-phase-multiphase phase number converter
title_full Determination of minimum secondary winding coils turns for transformer three-phase-multiphase phase number converter
title_fullStr Determination of minimum secondary winding coils turns for transformer three-phase-multiphase phase number converter
title_full_unstemmed Determination of minimum secondary winding coils turns for transformer three-phase-multiphase phase number converter
title_short Determination of minimum secondary winding coils turns for transformer three-phase-multiphase phase number converter
title_sort determination of minimum secondary winding coils turns for transformer three phase multiphase phase number converter
topic transformer phase converter
multiphase winding
optimization amount of the coils turns
multiphase symmetric system
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%201%20(181)%20(%D0%9E%D0%9D%D0%92)/61-66%20%D0%9C%D0%BE%D1%81%D0%BA%D0%B0%D0%BB%D0%B5%D0%B2%20%D0%AE.%20%D0%92..pdf
work_keys_str_mv AT yuvmoskalev determinationofminimumsecondarywindingcoilsturnsfortransformerthreephasemultiphasephasenumberconverter