X-Ray Computed Tomography: Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments

Background. This study presents a semiautomated approach for volumetric analysis of lung tumors and evaluates the feasibility of using volumes as an alternative to line lengths as a basis for response evaluation criteria in solid tumors (RECIST). The overall goal for the implementation was to accura...

Full description

Saved in:
Bibliographic Details
Main Authors: C. Bendtsen, M. Kietzmann, R. Korn, P. D. Mozley, G. Schmidt, G. Binnig
Format: Article
Language:English
Published: Wiley 2011-01-01
Series:International Journal of Biomedical Imaging
Online Access:http://dx.doi.org/10.1155/2011/361589
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832565455565357056
author C. Bendtsen
M. Kietzmann
R. Korn
P. D. Mozley
G. Schmidt
G. Binnig
author_facet C. Bendtsen
M. Kietzmann
R. Korn
P. D. Mozley
G. Schmidt
G. Binnig
author_sort C. Bendtsen
collection DOAJ
description Background. This study presents a semiautomated approach for volumetric analysis of lung tumors and evaluates the feasibility of using volumes as an alternative to line lengths as a basis for response evaluation criteria in solid tumors (RECIST). The overall goal for the implementation was to accurately, precisely, and efficiently enable the analyses of lesions in the lung under the guidance of an operator. Methods. An anthropomorphic phantom with embedded model masses and 71 time points in 10 clinical cases with advanced lung cancer was analyzed using a semi-automated workflow. The implementation was done using the Cognition Network Technology. Results. Analysis of the phantom showed an average accuracy of 97%. The analyses of the clinical cases showed both intra- and interreader variabilities of approximately 5% on average with an upper 95% confidence interval of 14% and 19%, respectively. Compared to line lengths, the use of volumes clearly shows enhanced sensitivity with respect to determining response to therapy. Conclusions. It is feasible to perform volumetric analysis efficiently with high accuracy and low variability, even in patients with late-stage cancer who have complex lesions.
format Article
id doaj-art-865ecd0f059949948ec8b6295ea22d0d
institution Kabale University
issn 1687-4188
1687-4196
language English
publishDate 2011-01-01
publisher Wiley
record_format Article
series International Journal of Biomedical Imaging
spelling doaj-art-865ecd0f059949948ec8b6295ea22d0d2025-02-03T01:07:32ZengWileyInternational Journal of Biomedical Imaging1687-41881687-41962011-01-01201110.1155/2011/361589361589X-Ray Computed Tomography: Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response AssessmentsC. Bendtsen0M. Kietzmann1R. Korn2P. D. Mozley3G. Schmidt4G. Binnig5DECS, AstraZeneca, 50S27 Mereside, Alderley Park, Macclesfield, Cheshire SK10 4TG, UKDefiniens AG, Trappentreustraße 1, 80339 München, GermanyDefiniens AG, Trappentreustraße 1, 80339 München, GermanyDepartment of Imaging, Merck Research Laboratories, 770 Sumneytown Pike, WP42-305, West Point, PA 19486-0004, USADefiniens AG, Trappentreustraße 1, 80339 München, GermanyDefiniens AG, Trappentreustraße 1, 80339 München, GermanyBackground. This study presents a semiautomated approach for volumetric analysis of lung tumors and evaluates the feasibility of using volumes as an alternative to line lengths as a basis for response evaluation criteria in solid tumors (RECIST). The overall goal for the implementation was to accurately, precisely, and efficiently enable the analyses of lesions in the lung under the guidance of an operator. Methods. An anthropomorphic phantom with embedded model masses and 71 time points in 10 clinical cases with advanced lung cancer was analyzed using a semi-automated workflow. The implementation was done using the Cognition Network Technology. Results. Analysis of the phantom showed an average accuracy of 97%. The analyses of the clinical cases showed both intra- and interreader variabilities of approximately 5% on average with an upper 95% confidence interval of 14% and 19%, respectively. Compared to line lengths, the use of volumes clearly shows enhanced sensitivity with respect to determining response to therapy. Conclusions. It is feasible to perform volumetric analysis efficiently with high accuracy and low variability, even in patients with late-stage cancer who have complex lesions.http://dx.doi.org/10.1155/2011/361589
spellingShingle C. Bendtsen
M. Kietzmann
R. Korn
P. D. Mozley
G. Schmidt
G. Binnig
X-Ray Computed Tomography: Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments
International Journal of Biomedical Imaging
title X-Ray Computed Tomography: Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments
title_full X-Ray Computed Tomography: Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments
title_fullStr X-Ray Computed Tomography: Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments
title_full_unstemmed X-Ray Computed Tomography: Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments
title_short X-Ray Computed Tomography: Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments
title_sort x ray computed tomography semiautomated volumetric analysis of late stage lung tumors as a basis for response assessments
url http://dx.doi.org/10.1155/2011/361589
work_keys_str_mv AT cbendtsen xraycomputedtomographysemiautomatedvolumetricanalysisoflatestagelungtumorsasabasisforresponseassessments
AT mkietzmann xraycomputedtomographysemiautomatedvolumetricanalysisoflatestagelungtumorsasabasisforresponseassessments
AT rkorn xraycomputedtomographysemiautomatedvolumetricanalysisoflatestagelungtumorsasabasisforresponseassessments
AT pdmozley xraycomputedtomographysemiautomatedvolumetricanalysisoflatestagelungtumorsasabasisforresponseassessments
AT gschmidt xraycomputedtomographysemiautomatedvolumetricanalysisoflatestagelungtumorsasabasisforresponseassessments
AT gbinnig xraycomputedtomographysemiautomatedvolumetricanalysisoflatestagelungtumorsasabasisforresponseassessments