Refractive and Quality of Vision Outcomes with Toric IOL Implantation in Low Astigmatism

Purpose. To evaluate the refractive and the quality of vision outcomes of toric IOL implantation in patients with low astigmatism. Design. Prospective study of single-arm. Methods. Patients with corneal astigmatism range from 0,75 D to 1,5 D and cataract that underwent cataract surgery with toric IO...

Full description

Saved in:
Bibliographic Details
Main Authors: Eduardo Scaldini Buscacio, Lia Florim Patrão, Haroldo Vieira de Moraes
Format: Article
Language:English
Published: Wiley 2016-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2016/5424713
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832550628619976704
author Eduardo Scaldini Buscacio
Lia Florim Patrão
Haroldo Vieira de Moraes
author_facet Eduardo Scaldini Buscacio
Lia Florim Patrão
Haroldo Vieira de Moraes
author_sort Eduardo Scaldini Buscacio
collection DOAJ
description Purpose. To evaluate the refractive and the quality of vision outcomes of toric IOL implantation in patients with low astigmatism. Design. Prospective study of single-arm. Methods. Patients with corneal astigmatism range from 0,75 D to 1,5 D and cataract that underwent cataract surgery with toric IOL. The measurements were performed preoperatively and 6 weeks after the surgery. Patients were evaluated for visual acuity with and without correction, contrast sensitivity, static and dynamic refraction, and quality of life questionnaire. Pre- and postoperative values were compared and their variations were evaluated for linear correlation. Results. 21 eyes of 21 patients. Postoperative mean uncorrected visual acuity was 0.80±0.19, and the best corrected visual acuity was 0.97±0.15. p<0.001 compared to preoperative values. The average postoperative refractive cylinder was -0.34±0.39. The questionnaire’s total value before and after surgery was, respectively, 43.20±15.76 and 79.70±10.11 (p<0.001). The correlation coefficients between the values of the questionnaire variation and the UCVA, BCVA, and CS variation were, respectively, 0.548 (p=0.005), 0.508 (p=0.009), and 0.409 (p=0.033). Conclusion. Patients with low astigmatism who underwent phacoemulsification with toric IOL implantation experienced significant decrease in refractive astigmatism and improvement in their quality of life.
format Article
id doaj-art-70bf43c844ad4f50b66f2080e7f1700a
institution Kabale University
issn 2090-004X
2090-0058
language English
publishDate 2016-01-01
publisher Wiley
record_format Article
series Journal of Ophthalmology
spelling doaj-art-70bf43c844ad4f50b66f2080e7f1700a2025-02-03T06:06:20ZengWileyJournal of Ophthalmology2090-004X2090-00582016-01-01201610.1155/2016/54247135424713Refractive and Quality of Vision Outcomes with Toric IOL Implantation in Low AstigmatismEduardo Scaldini Buscacio0Lia Florim Patrão1Haroldo Vieira de Moraes2Federal University of Rio de Janeiro, Rio de Janeiro, RJ, BrazilHospital de Olhos Niterói, Rio de Janeiro, RJ, BrazilFederal University of Rio de Janeiro, Rio de Janeiro, RJ, BrazilPurpose. To evaluate the refractive and the quality of vision outcomes of toric IOL implantation in patients with low astigmatism. Design. Prospective study of single-arm. Methods. Patients with corneal astigmatism range from 0,75 D to 1,5 D and cataract that underwent cataract surgery with toric IOL. The measurements were performed preoperatively and 6 weeks after the surgery. Patients were evaluated for visual acuity with and without correction, contrast sensitivity, static and dynamic refraction, and quality of life questionnaire. Pre- and postoperative values were compared and their variations were evaluated for linear correlation. Results. 21 eyes of 21 patients. Postoperative mean uncorrected visual acuity was 0.80±0.19, and the best corrected visual acuity was 0.97±0.15. p<0.001 compared to preoperative values. The average postoperative refractive cylinder was -0.34±0.39. The questionnaire’s total value before and after surgery was, respectively, 43.20±15.76 and 79.70±10.11 (p<0.001). The correlation coefficients between the values of the questionnaire variation and the UCVA, BCVA, and CS variation were, respectively, 0.548 (p=0.005), 0.508 (p=0.009), and 0.409 (p=0.033). Conclusion. Patients with low astigmatism who underwent phacoemulsification with toric IOL implantation experienced significant decrease in refractive astigmatism and improvement in their quality of life.http://dx.doi.org/10.1155/2016/5424713
spellingShingle Eduardo Scaldini Buscacio
Lia Florim Patrão
Haroldo Vieira de Moraes
Refractive and Quality of Vision Outcomes with Toric IOL Implantation in Low Astigmatism
Journal of Ophthalmology
title Refractive and Quality of Vision Outcomes with Toric IOL Implantation in Low Astigmatism
title_full Refractive and Quality of Vision Outcomes with Toric IOL Implantation in Low Astigmatism
title_fullStr Refractive and Quality of Vision Outcomes with Toric IOL Implantation in Low Astigmatism
title_full_unstemmed Refractive and Quality of Vision Outcomes with Toric IOL Implantation in Low Astigmatism
title_short Refractive and Quality of Vision Outcomes with Toric IOL Implantation in Low Astigmatism
title_sort refractive and quality of vision outcomes with toric iol implantation in low astigmatism
url http://dx.doi.org/10.1155/2016/5424713
work_keys_str_mv AT eduardoscaldinibuscacio refractiveandqualityofvisionoutcomeswithtoriciolimplantationinlowastigmatism
AT liaflorimpatrao refractiveandqualityofvisionoutcomeswithtoriciolimplantationinlowastigmatism
AT haroldovieirademoraes refractiveandqualityofvisionoutcomeswithtoriciolimplantationinlowastigmatism