Quantitative assessment of brain metabolism in mice using non-contrast MRI at 11.7T

Brain oxygen metabolism indicates the rate of energy consumption and is a potential marker of pathological changes. Positron emission tomography (PET) is the gold standard for measuring metabolic rates using radioactive tracers. However, its application in preclinical studies, particularly with rode...

Full description

Saved in:
Bibliographic Details
Main Authors: Xiuli Yang, Yuguo Li, Hanzhang Lu, Zhiliang Wei
Format: Article
Language:English
Published: Elsevier 2025-06-01
Series:MethodsX
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2215016125000238
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832585131512037376
author Xiuli Yang
Yuguo Li
Hanzhang Lu
Zhiliang Wei
author_facet Xiuli Yang
Yuguo Li
Hanzhang Lu
Zhiliang Wei
author_sort Xiuli Yang
collection DOAJ
description Brain oxygen metabolism indicates the rate of energy consumption and is a potential marker of pathological changes. Positron emission tomography (PET) is the gold standard for measuring metabolic rates using radioactive tracers. However, its application in preclinical studies, particularly with rodent animals, is constrained by the need for arterial input function measurements and on-site cyclotron facilities for tracer preparation. As an alternative, non-invasive, non-contrast MRI techniques, such as T2-relaxation-under-spin-tagging (TRUST) and phase-contrast (PC) MRI, can be used for evaluating brain metabolism in vivo. This study outlines a step-by-step method for implementing TRUST and PC MRI in mice at 11.7T scanner. The proposed method yields non-invasive, non-contrast quantitative measurements of global brain metabolism in approximately 20 min, paving the way for broader applications in future pathophysiological studies. • Non-invasive and non-contrast assessment of brain metabolism in mice. • Quantitative measurement of metabolic rate in approximately 20 min.
format Article
id doaj-art-6a1e5dd0428c43d49dde5b624ba2df9e
institution Kabale University
issn 2215-0161
language English
publishDate 2025-06-01
publisher Elsevier
record_format Article
series MethodsX
spelling doaj-art-6a1e5dd0428c43d49dde5b624ba2df9e2025-01-27T04:21:59ZengElsevierMethodsX2215-01612025-06-0114103175Quantitative assessment of brain metabolism in mice using non-contrast MRI at 11.7TXiuli Yang0Yuguo Li1Hanzhang Lu2Zhiliang Wei3Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, United StatesDepartment of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, United StatesDepartment of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, United StatesCorresponding author.; Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, United StatesBrain oxygen metabolism indicates the rate of energy consumption and is a potential marker of pathological changes. Positron emission tomography (PET) is the gold standard for measuring metabolic rates using radioactive tracers. However, its application in preclinical studies, particularly with rodent animals, is constrained by the need for arterial input function measurements and on-site cyclotron facilities for tracer preparation. As an alternative, non-invasive, non-contrast MRI techniques, such as T2-relaxation-under-spin-tagging (TRUST) and phase-contrast (PC) MRI, can be used for evaluating brain metabolism in vivo. This study outlines a step-by-step method for implementing TRUST and PC MRI in mice at 11.7T scanner. The proposed method yields non-invasive, non-contrast quantitative measurements of global brain metabolism in approximately 20 min, paving the way for broader applications in future pathophysiological studies. • Non-invasive and non-contrast assessment of brain metabolism in mice. • Quantitative measurement of metabolic rate in approximately 20 min.http://www.sciencedirect.com/science/article/pii/S2215016125000238Cerebral metabolic rate of oxygen (CMRO2)Cerebral blood flow (CBF)Fick principleT2-relaxation-under-spin-tagging (TRUST)Phase contrast (PC)
spellingShingle Xiuli Yang
Yuguo Li
Hanzhang Lu
Zhiliang Wei
Quantitative assessment of brain metabolism in mice using non-contrast MRI at 11.7T
MethodsX
Cerebral metabolic rate of oxygen (CMRO2)
Cerebral blood flow (CBF)
Fick principle
T2-relaxation-under-spin-tagging (TRUST)
Phase contrast (PC)
title Quantitative assessment of brain metabolism in mice using non-contrast MRI at 11.7T
title_full Quantitative assessment of brain metabolism in mice using non-contrast MRI at 11.7T
title_fullStr Quantitative assessment of brain metabolism in mice using non-contrast MRI at 11.7T
title_full_unstemmed Quantitative assessment of brain metabolism in mice using non-contrast MRI at 11.7T
title_short Quantitative assessment of brain metabolism in mice using non-contrast MRI at 11.7T
title_sort quantitative assessment of brain metabolism in mice using non contrast mri at 11 7t
topic Cerebral metabolic rate of oxygen (CMRO2)
Cerebral blood flow (CBF)
Fick principle
T2-relaxation-under-spin-tagging (TRUST)
Phase contrast (PC)
url http://www.sciencedirect.com/science/article/pii/S2215016125000238
work_keys_str_mv AT xiuliyang quantitativeassessmentofbrainmetabolisminmiceusingnoncontrastmriat117t
AT yuguoli quantitativeassessmentofbrainmetabolisminmiceusingnoncontrastmriat117t
AT hanzhanglu quantitativeassessmentofbrainmetabolisminmiceusingnoncontrastmriat117t
AT zhiliangwei quantitativeassessmentofbrainmetabolisminmiceusingnoncontrastmriat117t