Questions of constructing probe active control devices for product sizes
The article presents probe active control devices (ACD) of the size of products, describes the composition, versions, principle and modes of operation. The measurements are carried out by two-coordinate vibration oscillations of the tip along a closed path with a section of co-directional motion...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
2018-09-01
|
Series: | Омский научный вестник |
Subjects: | |
Online Access: | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/4%20(160)/127-133%20%D0%9B%D0%B5%D1%83%D0%BD%20%D0%95.%20%D0%92..pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The article presents probe active control devices (ACD) of the
size of products, describes the composition, versions, principle
and modes of operation. The measurements are carried out by
two-coordinate vibration oscillations of the tip along a closed path
with a section of co-directional motion and mechanical contact of
the lс with the surface of the moving product. The tip moves vtip
with a slight lag from products vdet with a small relative velocity
, thus implementing a moving feeling, like a needle profilometer or a cantilever, measuring its position in two coordinates lx and ly.
The measurements consist of a sequence of such feelings.
The article discusses the issues of the functionality, continuity and
accuracy of probe ACD measurements. |
---|---|
ISSN: | 1813-8225 2541-7541 |