Durability of Residual Strength on Ac-Wc Mixture Using Bottom Ash As Fine Aggregate Substitution

Abstract. This study aims to determine the durability of the residual strength in the Asphalt Concrete – Wearing Course (AC-WC) mixture that uses bottom ash waste as a substitute for fine aggregate. The Marshall Test revealed that the stability value of all variations of the tested immersion met the...

Full description

Saved in:
Bibliographic Details
Main Authors: Irianto Irianto, Didik S.S Mabui, Ardi Azis Sila
Format: Article
Language:English
Published: Universitas Negeri Semarang 2022-04-01
Series:Jurnal Teknik Sipil dan Perencanaan
Subjects:
Online Access:https://journal.unnes.ac.id/nju/jtsp/article/view/31913
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850223858023399424
author Irianto Irianto
Didik S.S Mabui
Ardi Azis Sila
author_facet Irianto Irianto
Didik S.S Mabui
Ardi Azis Sila
author_sort Irianto Irianto
collection DOAJ
description Abstract. This study aims to determine the durability of the residual strength in the Asphalt Concrete – Wearing Course (AC-WC) mixture that uses bottom ash waste as a substitute for fine aggregate. The Marshall Test revealed that the stability value of all variations of the tested immersion met the minimum standard, which was greater than 800 kg, namely for the 0 hour immersion variation of 2170.75 kg, the 24-hour immersion variation of 2014, 62 kg, the immersion variation 48 hours of 1938.07 kg, variation of immersion 96 hours of 1853.45 kg, and the variation of immersion 168 hours of stability value obtained is 1747.68 kg. And for the residual strength index in the 24-hour immersion variation the residual stability index was obtained at 92.81%, for the 48-hour immersion variation the residual stability index was obtained at 89.33%, while for the 96-hour immersion variation the residual stability index was obtained at 85.38%. and for the variation of immersion 168 hours residual stability index was obtained at 80.51%, so that which meets the standard of at least 90% is the 24-hour variation.
format Article
id doaj-art-57c1dc7f90184821be5a5448aa6eeb51
institution OA Journals
issn 1411-1772
2503-1899
language English
publishDate 2022-04-01
publisher Universitas Negeri Semarang
record_format Article
series Jurnal Teknik Sipil dan Perencanaan
spelling doaj-art-57c1dc7f90184821be5a5448aa6eeb512025-08-20T02:05:48ZengUniversitas Negeri SemarangJurnal Teknik Sipil dan Perencanaan1411-17722503-18992022-04-01241425110.15294/jtsp.v24i1.3191312593Durability of Residual Strength on Ac-Wc Mixture Using Bottom Ash As Fine Aggregate SubstitutionIrianto Irianto0Didik S.S MabuiArdi Azis SilaUNIVERSITAS YAPIS PAPUAAbstract. This study aims to determine the durability of the residual strength in the Asphalt Concrete – Wearing Course (AC-WC) mixture that uses bottom ash waste as a substitute for fine aggregate. The Marshall Test revealed that the stability value of all variations of the tested immersion met the minimum standard, which was greater than 800 kg, namely for the 0 hour immersion variation of 2170.75 kg, the 24-hour immersion variation of 2014, 62 kg, the immersion variation 48 hours of 1938.07 kg, variation of immersion 96 hours of 1853.45 kg, and the variation of immersion 168 hours of stability value obtained is 1747.68 kg. And for the residual strength index in the 24-hour immersion variation the residual stability index was obtained at 92.81%, for the 48-hour immersion variation the residual stability index was obtained at 89.33%, while for the 96-hour immersion variation the residual stability index was obtained at 85.38%. and for the variation of immersion 168 hours residual stability index was obtained at 80.51%, so that which meets the standard of at least 90% is the 24-hour variation.https://journal.unnes.ac.id/nju/jtsp/article/view/31913patterns of settlement distribution, disaster-prone areas, geographic information system (gis)
spellingShingle Irianto Irianto
Didik S.S Mabui
Ardi Azis Sila
Durability of Residual Strength on Ac-Wc Mixture Using Bottom Ash As Fine Aggregate Substitution
Jurnal Teknik Sipil dan Perencanaan
patterns of settlement distribution, disaster-prone areas, geographic information system (gis)
title Durability of Residual Strength on Ac-Wc Mixture Using Bottom Ash As Fine Aggregate Substitution
title_full Durability of Residual Strength on Ac-Wc Mixture Using Bottom Ash As Fine Aggregate Substitution
title_fullStr Durability of Residual Strength on Ac-Wc Mixture Using Bottom Ash As Fine Aggregate Substitution
title_full_unstemmed Durability of Residual Strength on Ac-Wc Mixture Using Bottom Ash As Fine Aggregate Substitution
title_short Durability of Residual Strength on Ac-Wc Mixture Using Bottom Ash As Fine Aggregate Substitution
title_sort durability of residual strength on ac wc mixture using bottom ash as fine aggregate substitution
topic patterns of settlement distribution, disaster-prone areas, geographic information system (gis)
url https://journal.unnes.ac.id/nju/jtsp/article/view/31913
work_keys_str_mv AT iriantoirianto durabilityofresidualstrengthonacwcmixtureusingbottomashasfineaggregatesubstitution
AT didikssmabui durabilityofresidualstrengthonacwcmixtureusingbottomashasfineaggregatesubstitution
AT ardiazissila durabilityofresidualstrengthonacwcmixtureusingbottomashasfineaggregatesubstitution