Does the resistive index of the radial artery change after arterial cannulation in patients undergoing abdominal surgery? A prospective observational study

Background and Aims: To evaluate the flow at the cannulation site in the radial artery, the resistive indices (RIs) before cannula insertion and 6 h after decannulation were measured (primary outcome). The secondary outcomes were measurement of the artery size by anteroposterior (AP) diameter at the...

Full description

Saved in:
Bibliographic Details
Main Authors: Lakshmi Kumar, Rajasri Subramaniam, P Anandajith Kartha, Dimple E. Thomas, Sunil Patel, Niveditha Kartha
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2024-10-01
Series:Indian Journal of Anaesthesia
Subjects:
Online Access:https://journals.lww.com/10.4103/ija.ija_628_24
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832587212613484544
author Lakshmi Kumar
Rajasri Subramaniam
P Anandajith Kartha
Dimple E. Thomas
Sunil Patel
Niveditha Kartha
author_facet Lakshmi Kumar
Rajasri Subramaniam
P Anandajith Kartha
Dimple E. Thomas
Sunil Patel
Niveditha Kartha
author_sort Lakshmi Kumar
collection DOAJ
description Background and Aims: To evaluate the flow at the cannulation site in the radial artery, the resistive indices (RIs) before cannula insertion and 6 h after decannulation were measured (primary outcome). The secondary outcomes were measurement of the artery size by anteroposterior (AP) diameter at the insertion site, RI and AP diameter at a point 4 cm proximal and in the ipsilateral ulnar artery before insertion and 6 h after cannula removal. Methods: In 96 patients requiring an arterial line during surgery, peak systolic velocity (PSV) and end-diastolic velocity (EDV) were measured to derive RI using a linear ultrasound transducer. The RI was measured at R1 (insertion point), R2, 4 cm proximal to R1, and U1 on the ipsilateral ulnar artery. The AP diameter of the arteries at baseline R10, R20 and U10 was measured and repeated 6 h after removal of the cannula, R16, R26 and U16. Results: RI or AP diameter in R1 or R2 did not differ pre- and post-cannulation. Mean R10 1.143 [standard deviation (SD: 0.239)] versus R16 1.181 (SD: 0.260) m/sec [mean difference (MD): -0.0372 (95% confidence interval (CI): -0.098, 0.023), P = 0.230]. Mean AP diameter at baseline versus 6 h decannulation 0.177 (SD: 0.042) versus 0.172 (SD: 0.045) cm [MD: 0.005 (95% CI: 0.003, 0.013), P = 0.222] was also similar. The mean PSV in U10 versus U16 was higher: 0.480 (SD: 0.178) versus 0.528 (SD: 0.316) m/sec [MD: 0.120 (95% CI: -0.185, -0.054), P = 0.002] and AP diameter was also higher than baseline (P = 0.001). Conclusion: The flow in the radial artery did not change following cannulation. The PSV and AP diameter in the ulnar artery increased after decannulation, suggesting a compensatory increase in flow.
format Article
id doaj-art-54b9e3e87c9c416fad6a0a2737f08b02
institution Kabale University
issn 0019-5049
0976-2817
language English
publishDate 2024-10-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Indian Journal of Anaesthesia
spelling doaj-art-54b9e3e87c9c416fad6a0a2737f08b022025-01-24T15:06:59ZengWolters Kluwer Medknow PublicationsIndian Journal of Anaesthesia0019-50490976-28172024-10-01681090991410.4103/ija.ija_628_24Does the resistive index of the radial artery change after arterial cannulation in patients undergoing abdominal surgery? A prospective observational studyLakshmi KumarRajasri SubramaniamP Anandajith KarthaDimple E. ThomasSunil PatelNiveditha KarthaBackground and Aims: To evaluate the flow at the cannulation site in the radial artery, the resistive indices (RIs) before cannula insertion and 6 h after decannulation were measured (primary outcome). The secondary outcomes were measurement of the artery size by anteroposterior (AP) diameter at the insertion site, RI and AP diameter at a point 4 cm proximal and in the ipsilateral ulnar artery before insertion and 6 h after cannula removal. Methods: In 96 patients requiring an arterial line during surgery, peak systolic velocity (PSV) and end-diastolic velocity (EDV) were measured to derive RI using a linear ultrasound transducer. The RI was measured at R1 (insertion point), R2, 4 cm proximal to R1, and U1 on the ipsilateral ulnar artery. The AP diameter of the arteries at baseline R10, R20 and U10 was measured and repeated 6 h after removal of the cannula, R16, R26 and U16. Results: RI or AP diameter in R1 or R2 did not differ pre- and post-cannulation. Mean R10 1.143 [standard deviation (SD: 0.239)] versus R16 1.181 (SD: 0.260) m/sec [mean difference (MD): -0.0372 (95% confidence interval (CI): -0.098, 0.023), P = 0.230]. Mean AP diameter at baseline versus 6 h decannulation 0.177 (SD: 0.042) versus 0.172 (SD: 0.045) cm [MD: 0.005 (95% CI: 0.003, 0.013), P = 0.222] was also similar. The mean PSV in U10 versus U16 was higher: 0.480 (SD: 0.178) versus 0.528 (SD: 0.316) m/sec [MD: 0.120 (95% CI: -0.185, -0.054), P = 0.002] and AP diameter was also higher than baseline (P = 0.001). Conclusion: The flow in the radial artery did not change following cannulation. The PSV and AP diameter in the ulnar artery increased after decannulation, suggesting a compensatory increase in flow.https://journals.lww.com/10.4103/ija.ija_628_24cannulationend-diastolic velocitypeak systolic velocityradial arteryresistive indexulnar artery
spellingShingle Lakshmi Kumar
Rajasri Subramaniam
P Anandajith Kartha
Dimple E. Thomas
Sunil Patel
Niveditha Kartha
Does the resistive index of the radial artery change after arterial cannulation in patients undergoing abdominal surgery? A prospective observational study
Indian Journal of Anaesthesia
cannulation
end-diastolic velocity
peak systolic velocity
radial artery
resistive index
ulnar artery
title Does the resistive index of the radial artery change after arterial cannulation in patients undergoing abdominal surgery? A prospective observational study
title_full Does the resistive index of the radial artery change after arterial cannulation in patients undergoing abdominal surgery? A prospective observational study
title_fullStr Does the resistive index of the radial artery change after arterial cannulation in patients undergoing abdominal surgery? A prospective observational study
title_full_unstemmed Does the resistive index of the radial artery change after arterial cannulation in patients undergoing abdominal surgery? A prospective observational study
title_short Does the resistive index of the radial artery change after arterial cannulation in patients undergoing abdominal surgery? A prospective observational study
title_sort does the resistive index of the radial artery change after arterial cannulation in patients undergoing abdominal surgery a prospective observational study
topic cannulation
end-diastolic velocity
peak systolic velocity
radial artery
resistive index
ulnar artery
url https://journals.lww.com/10.4103/ija.ija_628_24
work_keys_str_mv AT lakshmikumar doestheresistiveindexoftheradialarterychangeafterarterialcannulationinpatientsundergoingabdominalsurgeryaprospectiveobservationalstudy
AT rajasrisubramaniam doestheresistiveindexoftheradialarterychangeafterarterialcannulationinpatientsundergoingabdominalsurgeryaprospectiveobservationalstudy
AT panandajithkartha doestheresistiveindexoftheradialarterychangeafterarterialcannulationinpatientsundergoingabdominalsurgeryaprospectiveobservationalstudy
AT dimpleethomas doestheresistiveindexoftheradialarterychangeafterarterialcannulationinpatientsundergoingabdominalsurgeryaprospectiveobservationalstudy
AT sunilpatel doestheresistiveindexoftheradialarterychangeafterarterialcannulationinpatientsundergoingabdominalsurgeryaprospectiveobservationalstudy
AT nivedithakartha doestheresistiveindexoftheradialarterychangeafterarterialcannulationinpatientsundergoingabdominalsurgeryaprospectiveobservationalstudy