Monte Carlo Simulation to Evaluate Mould Growth in Walls: The Effect of Insulation, Orientation, and Finishing Coating

Mould growth can have severe consequences both on the health of occupants and on constructions’ durability. Mould growth is a very complex process that depends on many factors such as temperature and relative humidity, presence of nutrients, and exposure time. Several mould prediction models, which...

Full description

Saved in:
Bibliographic Details
Main Authors: Ricardo M. S. F. Almeida, Eva Barreira
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2018/8532167
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832566536308523008
author Ricardo M. S. F. Almeida
Eva Barreira
author_facet Ricardo M. S. F. Almeida
Eva Barreira
author_sort Ricardo M. S. F. Almeida
collection DOAJ
description Mould growth can have severe consequences both on the health of occupants and on constructions’ durability. Mould growth is a very complex process that depends on many factors such as temperature and relative humidity, presence of nutrients, and exposure time. Several mould prediction models, which allow estimating mould growth in building components and performing risk analysis, are available in the literature, such as the updated VTT model or the Biohygrothermal model. A Portuguese typical wall configuration was used for a sensitivity analysis. The importance of insulation (with and without insulation), orientation (north and south), and finishing coating (gypsum-based rendering, medium density fibreboard (mdf), and untreated wood) for the mould growth phenomenon was tested using both the updated VTT model and the Biohygrothermal model. A total of 12 case studies were investigated. The influence of indoor climate was evaluated by simulating 200 scenarios previously generated using the Monte Carlo method. Each of the scenarios has been applied to the 12 case studies, and 2400 hygrothermal simulations were carried out. Initially, the case studies were simulated using WUFI 1D since both mould growth models require the superficial temperature and relative humidity as input. Simulations were carried out for a one-year period. The updated VTT model produced results (mould index—M) ranging between 0.4 (gypsum-based rendering, insulated, and south oriented wall) and 5.9 (untreated wood, noninsulated, and north oriented wall) and the Biohygrothermal model (mould growth) between 10.1 and 406.4 mm for the same case studies. Despite that the effect of the orientation of the wall could be identified, the importance of insulation and nature of substrate was more evident. Although the two models produced overall comparable results, some differences could be found, creating the opportunity to discuss their strengths and weaknesses as well as their sensitivity to the input parameters.
format Article
id doaj-art-536b1be9a6b2429c9d3eeecdd95c379c
institution Kabale University
issn 1687-8086
1687-8094
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-536b1be9a6b2429c9d3eeecdd95c379c2025-02-03T01:03:46ZengWileyAdvances in Civil Engineering1687-80861687-80942018-01-01201810.1155/2018/85321678532167Monte Carlo Simulation to Evaluate Mould Growth in Walls: The Effect of Insulation, Orientation, and Finishing CoatingRicardo M. S. F. Almeida0Eva Barreira1Department of Civil Engineering, School of Technology and Management, Polytechnic Institute of Viseu, Campus Politécnico de Repeses, 3504-510 Viseu, PortugalCONSTRUCT-LFC, Faculdade de Engenharia (FEUP), Universidade do Porto, Rua Dr. Roberto Frias s/n, 4200-465 Porto, PortugalMould growth can have severe consequences both on the health of occupants and on constructions’ durability. Mould growth is a very complex process that depends on many factors such as temperature and relative humidity, presence of nutrients, and exposure time. Several mould prediction models, which allow estimating mould growth in building components and performing risk analysis, are available in the literature, such as the updated VTT model or the Biohygrothermal model. A Portuguese typical wall configuration was used for a sensitivity analysis. The importance of insulation (with and without insulation), orientation (north and south), and finishing coating (gypsum-based rendering, medium density fibreboard (mdf), and untreated wood) for the mould growth phenomenon was tested using both the updated VTT model and the Biohygrothermal model. A total of 12 case studies were investigated. The influence of indoor climate was evaluated by simulating 200 scenarios previously generated using the Monte Carlo method. Each of the scenarios has been applied to the 12 case studies, and 2400 hygrothermal simulations were carried out. Initially, the case studies were simulated using WUFI 1D since both mould growth models require the superficial temperature and relative humidity as input. Simulations were carried out for a one-year period. The updated VTT model produced results (mould index—M) ranging between 0.4 (gypsum-based rendering, insulated, and south oriented wall) and 5.9 (untreated wood, noninsulated, and north oriented wall) and the Biohygrothermal model (mould growth) between 10.1 and 406.4 mm for the same case studies. Despite that the effect of the orientation of the wall could be identified, the importance of insulation and nature of substrate was more evident. Although the two models produced overall comparable results, some differences could be found, creating the opportunity to discuss their strengths and weaknesses as well as their sensitivity to the input parameters.http://dx.doi.org/10.1155/2018/8532167
spellingShingle Ricardo M. S. F. Almeida
Eva Barreira
Monte Carlo Simulation to Evaluate Mould Growth in Walls: The Effect of Insulation, Orientation, and Finishing Coating
Advances in Civil Engineering
title Monte Carlo Simulation to Evaluate Mould Growth in Walls: The Effect of Insulation, Orientation, and Finishing Coating
title_full Monte Carlo Simulation to Evaluate Mould Growth in Walls: The Effect of Insulation, Orientation, and Finishing Coating
title_fullStr Monte Carlo Simulation to Evaluate Mould Growth in Walls: The Effect of Insulation, Orientation, and Finishing Coating
title_full_unstemmed Monte Carlo Simulation to Evaluate Mould Growth in Walls: The Effect of Insulation, Orientation, and Finishing Coating
title_short Monte Carlo Simulation to Evaluate Mould Growth in Walls: The Effect of Insulation, Orientation, and Finishing Coating
title_sort monte carlo simulation to evaluate mould growth in walls the effect of insulation orientation and finishing coating
url http://dx.doi.org/10.1155/2018/8532167
work_keys_str_mv AT ricardomsfalmeida montecarlosimulationtoevaluatemouldgrowthinwallstheeffectofinsulationorientationandfinishingcoating
AT evabarreira montecarlosimulationtoevaluatemouldgrowthinwallstheeffectofinsulationorientationandfinishingcoating