Development of a Plantar Load Estimation Algorithm for Evaluation of Forefoot Load of Diabetic Patients during Daily Walks Using a Foot Motion Sensor
Forefoot load (FL) contributes to callus formation, which is one of the pathways to diabetic foot ulcers (DFU). In this study, we hypothesized that excessive FL, which cannot be detected by plantar load measurements within laboratory settings, occurs in daily walks. To demonstrate this, we created a...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2017-01-01
|
Series: | Journal of Diabetes Research |
Online Access: | http://dx.doi.org/10.1155/2017/5350616 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832563772013674496 |
---|---|
author | Ayano Watanabe Hiroshi Noguchi Makoto Oe Hiromi Sanada Taketoshi Mori |
author_facet | Ayano Watanabe Hiroshi Noguchi Makoto Oe Hiromi Sanada Taketoshi Mori |
author_sort | Ayano Watanabe |
collection | DOAJ |
description | Forefoot load (FL) contributes to callus formation, which is one of the pathways to diabetic foot ulcers (DFU). In this study, we hypothesized that excessive FL, which cannot be detected by plantar load measurements within laboratory settings, occurs in daily walks. To demonstrate this, we created a FL estimation algorithm using foot motion data. Acceleration and angular velocity data were obtained from a motion sensor attached to each shoe of the subjects. The accuracy of the estimated FL was validated by correlation with the FL measured by force sensors on the metatarsal heads, which was assessed using the Pearson correlation coefficient. The mean of correlation coefficients of all the subjects was 0.63 at a level corridor, while it showed an intersubject difference at a slope and stairs. We conducted daily walk measurements in two diabetic patients, and additionally, we verified the safety of daily walk measurement using a wearable motion sensor attached to each shoe. We found that excessive FL occurred during their daily walks for approximately three hours in total, when any adverse event was not observed. This study indicated that FL evaluation method using wearable motion sensors was one of the promising ways to prevent DFUs. |
format | Article |
id | doaj-art-521dac8017e1413e88960c5d12c567f2 |
institution | Kabale University |
issn | 2314-6745 2314-6753 |
language | English |
publishDate | 2017-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Diabetes Research |
spelling | doaj-art-521dac8017e1413e88960c5d12c567f22025-02-03T01:12:31ZengWileyJournal of Diabetes Research2314-67452314-67532017-01-01201710.1155/2017/53506165350616Development of a Plantar Load Estimation Algorithm for Evaluation of Forefoot Load of Diabetic Patients during Daily Walks Using a Foot Motion SensorAyano Watanabe0Hiroshi Noguchi1Makoto Oe2Hiromi Sanada3Taketoshi Mori4Department of Gerontology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, JapanDepartment of Life Support Technology (Molten), Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, JapanDepartment of Advanced Nursing Technology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, JapanDepartment of Gerontology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, JapanDepartment of Life Support Technology (Molten), Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, JapanForefoot load (FL) contributes to callus formation, which is one of the pathways to diabetic foot ulcers (DFU). In this study, we hypothesized that excessive FL, which cannot be detected by plantar load measurements within laboratory settings, occurs in daily walks. To demonstrate this, we created a FL estimation algorithm using foot motion data. Acceleration and angular velocity data were obtained from a motion sensor attached to each shoe of the subjects. The accuracy of the estimated FL was validated by correlation with the FL measured by force sensors on the metatarsal heads, which was assessed using the Pearson correlation coefficient. The mean of correlation coefficients of all the subjects was 0.63 at a level corridor, while it showed an intersubject difference at a slope and stairs. We conducted daily walk measurements in two diabetic patients, and additionally, we verified the safety of daily walk measurement using a wearable motion sensor attached to each shoe. We found that excessive FL occurred during their daily walks for approximately three hours in total, when any adverse event was not observed. This study indicated that FL evaluation method using wearable motion sensors was one of the promising ways to prevent DFUs.http://dx.doi.org/10.1155/2017/5350616 |
spellingShingle | Ayano Watanabe Hiroshi Noguchi Makoto Oe Hiromi Sanada Taketoshi Mori Development of a Plantar Load Estimation Algorithm for Evaluation of Forefoot Load of Diabetic Patients during Daily Walks Using a Foot Motion Sensor Journal of Diabetes Research |
title | Development of a Plantar Load Estimation Algorithm for Evaluation of Forefoot Load of Diabetic Patients during Daily Walks Using a Foot Motion Sensor |
title_full | Development of a Plantar Load Estimation Algorithm for Evaluation of Forefoot Load of Diabetic Patients during Daily Walks Using a Foot Motion Sensor |
title_fullStr | Development of a Plantar Load Estimation Algorithm for Evaluation of Forefoot Load of Diabetic Patients during Daily Walks Using a Foot Motion Sensor |
title_full_unstemmed | Development of a Plantar Load Estimation Algorithm for Evaluation of Forefoot Load of Diabetic Patients during Daily Walks Using a Foot Motion Sensor |
title_short | Development of a Plantar Load Estimation Algorithm for Evaluation of Forefoot Load of Diabetic Patients during Daily Walks Using a Foot Motion Sensor |
title_sort | development of a plantar load estimation algorithm for evaluation of forefoot load of diabetic patients during daily walks using a foot motion sensor |
url | http://dx.doi.org/10.1155/2017/5350616 |
work_keys_str_mv | AT ayanowatanabe developmentofaplantarloadestimationalgorithmforevaluationofforefootloadofdiabeticpatientsduringdailywalksusingafootmotionsensor AT hiroshinoguchi developmentofaplantarloadestimationalgorithmforevaluationofforefootloadofdiabeticpatientsduringdailywalksusingafootmotionsensor AT makotooe developmentofaplantarloadestimationalgorithmforevaluationofforefootloadofdiabeticpatientsduringdailywalksusingafootmotionsensor AT hiromisanada developmentofaplantarloadestimationalgorithmforevaluationofforefootloadofdiabeticpatientsduringdailywalksusingafootmotionsensor AT taketoshimori developmentofaplantarloadestimationalgorithmforevaluationofforefootloadofdiabeticpatientsduringdailywalksusingafootmotionsensor |