Design of an Eddy Current Testing System for Non-Magnetic Hollow Tube Inspection
This paper presents an experimental setup for Eddy Current Non-Destructive Testing of non-magnetic hollow tubes. The system features movable coils and electronics for signal processing. The study explores the impact of defects on signal amplitude and investigates the influence of different freq...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | deu |
Published: |
NDT.net
2025-02-01
|
Series: | e-Journal of Nondestructive Testing |
Online Access: | https://www.ndt.net/search/docs.php3?id=30707 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832086570331537408 |
---|---|
author | Yasmine Belkahla Ghalem Hadri Khoussa Abdelhalim Taieb brahimi Nabil Boughanemi |
author_facet | Yasmine Belkahla Ghalem Hadri Khoussa Abdelhalim Taieb brahimi Nabil Boughanemi |
author_sort | Yasmine Belkahla |
collection | DOAJ |
description |
This paper presents an experimental setup for Eddy Current Non-Destructive Testing of non-magnetic hollow tubes. The system
features movable coils and electronics for signal processing. The study explores the impact of defects on signal amplitude and
investigates the influence of different frequencies (1-100 kHz) on detection capability. Results demonstrate the system's
effectiveness in detecting defects while highlighting challenges in noise reduction and the importance of frequency selection
for accurate detection.
|
format | Article |
id | doaj-art-4bba6834d2824489b9c6a493edc9a809 |
institution | Kabale University |
issn | 1435-4934 |
language | deu |
publishDate | 2025-02-01 |
publisher | NDT.net |
record_format | Article |
series | e-Journal of Nondestructive Testing |
spelling | doaj-art-4bba6834d2824489b9c6a493edc9a8092025-02-06T10:47:53ZdeuNDT.nete-Journal of Nondestructive Testing1435-49342025-02-0130210.58286/30707Design of an Eddy Current Testing System for Non-Magnetic Hollow Tube InspectionYasmine BelkahlaGhalem Hadri KhoussaAbdelhalim Taieb brahimiNabil Boughanemi This paper presents an experimental setup for Eddy Current Non-Destructive Testing of non-magnetic hollow tubes. The system features movable coils and electronics for signal processing. The study explores the impact of defects on signal amplitude and investigates the influence of different frequencies (1-100 kHz) on detection capability. Results demonstrate the system's effectiveness in detecting defects while highlighting challenges in noise reduction and the importance of frequency selection for accurate detection. https://www.ndt.net/search/docs.php3?id=30707 |
spellingShingle | Yasmine Belkahla Ghalem Hadri Khoussa Abdelhalim Taieb brahimi Nabil Boughanemi Design of an Eddy Current Testing System for Non-Magnetic Hollow Tube Inspection e-Journal of Nondestructive Testing |
title | Design of an Eddy Current Testing System for Non-Magnetic Hollow Tube Inspection |
title_full | Design of an Eddy Current Testing System for Non-Magnetic Hollow Tube Inspection |
title_fullStr | Design of an Eddy Current Testing System for Non-Magnetic Hollow Tube Inspection |
title_full_unstemmed | Design of an Eddy Current Testing System for Non-Magnetic Hollow Tube Inspection |
title_short | Design of an Eddy Current Testing System for Non-Magnetic Hollow Tube Inspection |
title_sort | design of an eddy current testing system for non magnetic hollow tube inspection |
url | https://www.ndt.net/search/docs.php3?id=30707 |
work_keys_str_mv | AT yasminebelkahla designofaneddycurrenttestingsystemfornonmagnetichollowtubeinspection AT ghalemhadrikhoussa designofaneddycurrenttestingsystemfornonmagnetichollowtubeinspection AT abdelhalimtaiebbrahimi designofaneddycurrenttestingsystemfornonmagnetichollowtubeinspection AT nabilboughanemi designofaneddycurrenttestingsystemfornonmagnetichollowtubeinspection |