Correlation between axial and coronal common bile duct diameters in computed tomography: a retrospective study of 1064 patients
Abstract Background The measurement of the common bile duct (CBD) diameter is essential for evaluating bile duct pathologies. The axial plane of computed tomography (CT) images is the established method for CBD diameter measurement. However, modern software enables easy reconstruction of axial CT im...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SpringerOpen
2025-01-01
|
Series: | The Egyptian Journal of Radiology and Nuclear Medicine |
Subjects: | |
Online Access: | https://doi.org/10.1186/s43055-025-01421-4 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832594896683270144 |
---|---|
author | Adisak Kasemassawachanont Natinee Chuangsuwanich Wanicha Lertpipopmetha Nutthanun Panrong Kittipott Thusneyapan Sasima Tongsai Napakadol Noppakunsomboon Rathachai Kaewlai |
author_facet | Adisak Kasemassawachanont Natinee Chuangsuwanich Wanicha Lertpipopmetha Nutthanun Panrong Kittipott Thusneyapan Sasima Tongsai Napakadol Noppakunsomboon Rathachai Kaewlai |
author_sort | Adisak Kasemassawachanont |
collection | DOAJ |
description | Abstract Background The measurement of the common bile duct (CBD) diameter is essential for evaluating bile duct pathologies. The axial plane of computed tomography (CT) images is the established method for CBD diameter measurement. However, modern software enables easy reconstruction of axial CT images into the coronal plane, allowing for CBD diameter measurement in this plane. This study aimed to investigate the correlation between measurements in the axial and coronal planes. Results The three reviewers demonstrated fair reliability in measuring CBD diameter in axial and coronal planes, with intraclass correlation coefficients of 0.776 and 0.799, respectively. A positive correlation was observed between the two diameters (r = 0.943), with 88.9% of axial diameter variation explained by coronal diameter and approximately 0.29 + (0.94 × coronal diameter) (R 2 = 0.889, p < 0.001). When a cutoff value of 7 mm was used to predict an abnormal axial diameter, the agreement between axial and coronal CBD diameters was substantial (Kappa = 0.715) with discordance between the two measurements identified in 6.2% of cases (66/1064) when a) coronal diameter < 7 mm but axial measurement ≥ 7 mm (39/1064; 3.7%) and b) coronal diameter ≥ 7 mm but axial measurement < 7 mm (27/1064; 2.5%). In univariable linear regression and multivariable analyses, the strongest independent factors associated with increased axial CBD diameter were presence of focal CBD lesion, age ≥ 60 years, and cholecystectomy. Conclusion There was a strong positive correlation between axial and coronal CBD diameters with substantial agreement when using a 7-mm cutoff and fair reliability in their measurements. |
format | Article |
id | doaj-art-48c1d70eccef433f94d3f1172d31e154 |
institution | Kabale University |
issn | 2090-4762 |
language | English |
publishDate | 2025-01-01 |
publisher | SpringerOpen |
record_format | Article |
series | The Egyptian Journal of Radiology and Nuclear Medicine |
spelling | doaj-art-48c1d70eccef433f94d3f1172d31e1542025-01-19T12:14:46ZengSpringerOpenThe Egyptian Journal of Radiology and Nuclear Medicine2090-47622025-01-015611910.1186/s43055-025-01421-4Correlation between axial and coronal common bile duct diameters in computed tomography: a retrospective study of 1064 patientsAdisak Kasemassawachanont0Natinee Chuangsuwanich1Wanicha Lertpipopmetha2Nutthanun Panrong3Kittipott Thusneyapan4Sasima Tongsai5Napakadol Noppakunsomboon6Rathachai Kaewlai7Department of Anatomy, Faculty of Medicine Siriraj Hospital, Mahidol UniversityDepartment of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol UniversityDepartment of Anatomy, Faculty of Medicine Siriraj Hospital, Mahidol UniversityDepartment of Anatomy, Faculty of Medicine Siriraj Hospital, Mahidol UniversityDepartment of Anatomy, Faculty of Medicine Siriraj Hospital, Mahidol UniversityDepartment of Research, Faculty of Medicine Siriraj Hospital, Mahidol UniversityDepartment of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol UniversityDepartment of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol UniversityAbstract Background The measurement of the common bile duct (CBD) diameter is essential for evaluating bile duct pathologies. The axial plane of computed tomography (CT) images is the established method for CBD diameter measurement. However, modern software enables easy reconstruction of axial CT images into the coronal plane, allowing for CBD diameter measurement in this plane. This study aimed to investigate the correlation between measurements in the axial and coronal planes. Results The three reviewers demonstrated fair reliability in measuring CBD diameter in axial and coronal planes, with intraclass correlation coefficients of 0.776 and 0.799, respectively. A positive correlation was observed between the two diameters (r = 0.943), with 88.9% of axial diameter variation explained by coronal diameter and approximately 0.29 + (0.94 × coronal diameter) (R 2 = 0.889, p < 0.001). When a cutoff value of 7 mm was used to predict an abnormal axial diameter, the agreement between axial and coronal CBD diameters was substantial (Kappa = 0.715) with discordance between the two measurements identified in 6.2% of cases (66/1064) when a) coronal diameter < 7 mm but axial measurement ≥ 7 mm (39/1064; 3.7%) and b) coronal diameter ≥ 7 mm but axial measurement < 7 mm (27/1064; 2.5%). In univariable linear regression and multivariable analyses, the strongest independent factors associated with increased axial CBD diameter were presence of focal CBD lesion, age ≥ 60 years, and cholecystectomy. Conclusion There was a strong positive correlation between axial and coronal CBD diameters with substantial agreement when using a 7-mm cutoff and fair reliability in their measurements.https://doi.org/10.1186/s43055-025-01421-4Common bile ductTomography, computed tomographyX-rayMeasurementBiliary tract diseasesAdults |
spellingShingle | Adisak Kasemassawachanont Natinee Chuangsuwanich Wanicha Lertpipopmetha Nutthanun Panrong Kittipott Thusneyapan Sasima Tongsai Napakadol Noppakunsomboon Rathachai Kaewlai Correlation between axial and coronal common bile duct diameters in computed tomography: a retrospective study of 1064 patients The Egyptian Journal of Radiology and Nuclear Medicine Common bile duct Tomography, computed tomography X-ray Measurement Biliary tract diseases Adults |
title | Correlation between axial and coronal common bile duct diameters in computed tomography: a retrospective study of 1064 patients |
title_full | Correlation between axial and coronal common bile duct diameters in computed tomography: a retrospective study of 1064 patients |
title_fullStr | Correlation between axial and coronal common bile duct diameters in computed tomography: a retrospective study of 1064 patients |
title_full_unstemmed | Correlation between axial and coronal common bile duct diameters in computed tomography: a retrospective study of 1064 patients |
title_short | Correlation between axial and coronal common bile duct diameters in computed tomography: a retrospective study of 1064 patients |
title_sort | correlation between axial and coronal common bile duct diameters in computed tomography a retrospective study of 1064 patients |
topic | Common bile duct Tomography, computed tomography X-ray Measurement Biliary tract diseases Adults |
url | https://doi.org/10.1186/s43055-025-01421-4 |
work_keys_str_mv | AT adisakkasemassawachanont correlationbetweenaxialandcoronalcommonbileductdiametersincomputedtomographyaretrospectivestudyof1064patients AT natineechuangsuwanich correlationbetweenaxialandcoronalcommonbileductdiametersincomputedtomographyaretrospectivestudyof1064patients AT wanichalertpipopmetha correlationbetweenaxialandcoronalcommonbileductdiametersincomputedtomographyaretrospectivestudyof1064patients AT nutthanunpanrong correlationbetweenaxialandcoronalcommonbileductdiametersincomputedtomographyaretrospectivestudyof1064patients AT kittipottthusneyapan correlationbetweenaxialandcoronalcommonbileductdiametersincomputedtomographyaretrospectivestudyof1064patients AT sasimatongsai correlationbetweenaxialandcoronalcommonbileductdiametersincomputedtomographyaretrospectivestudyof1064patients AT napakadolnoppakunsomboon correlationbetweenaxialandcoronalcommonbileductdiametersincomputedtomographyaretrospectivestudyof1064patients AT rathachaikaewlai correlationbetweenaxialandcoronalcommonbileductdiametersincomputedtomographyaretrospectivestudyof1064patients |