DIAGNOSTICS OF THE HIGH-TORQUE ELECTRICAL MOTOR UNDER OPERATING CONDITIONS AT LOW TEMPERATURES IN VACUUM

Parameters of high-moment electrical motor working at low-temperatures and high vacuum were investigated. It has been demonstrated that pressure in conspiracy with temperature does not influence starting current of the motor. Temperature reduction from 293 up to 143 K increases starting current at a...

Full description

Saved in:
Bibliographic Details
Main Authors: A. V. Byeli, A. N. Karpovich, E. G. Bilenko
Format: Article
Language:English
Published: Belarusian National Technical University 2015-04-01
Series:Приборы и методы измерений
Subjects:
Online Access:https://pimi.bntu.by/jour/article/view/143
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543630467792896
author A. V. Byeli
A. N. Karpovich
E. G. Bilenko
author_facet A. V. Byeli
A. N. Karpovich
E. G. Bilenko
author_sort A. V. Byeli
collection DOAJ
description Parameters of high-moment electrical motor working at low-temperatures and high vacuum were investigated. It has been demonstrated that pressure in conspiracy with temperature does not influence starting current of the motor. Temperature reduction from 293 up to 143 K increases starting current at a factor of 3.5.
format Article
id doaj-art-451134d21b7e4f94b988f9301fd8b5f0
institution Kabale University
issn 2220-9506
2414-0473
language English
publishDate 2015-04-01
publisher Belarusian National Technical University
record_format Article
series Приборы и методы измерений
spelling doaj-art-451134d21b7e4f94b988f9301fd8b5f02025-02-03T11:37:42ZengBelarusian National Technical UniversityПриборы и методы измерений2220-95062414-04732015-04-01028187137DIAGNOSTICS OF THE HIGH-TORQUE ELECTRICAL MOTOR UNDER OPERATING CONDITIONS AT LOW TEMPERATURES IN VACUUMA. V. Byeli0A. N. Karpovich1E. G. Bilenko2Физико-технический институт НАН Беларуси, г. МинскФизико-технический институт НАН Беларуси, г. МинскФизико-технический институт НАН Беларуси, г. МинскParameters of high-moment electrical motor working at low-temperatures and high vacuum were investigated. It has been demonstrated that pressure in conspiracy with temperature does not influence starting current of the motor. Temperature reduction from 293 up to 143 K increases starting current at a factor of 3.5.https://pimi.bntu.by/jour/article/view/143high-moment electrical motorimitation of space
spellingShingle A. V. Byeli
A. N. Karpovich
E. G. Bilenko
DIAGNOSTICS OF THE HIGH-TORQUE ELECTRICAL MOTOR UNDER OPERATING CONDITIONS AT LOW TEMPERATURES IN VACUUM
Приборы и методы измерений
high-moment electrical motor
imitation of space
title DIAGNOSTICS OF THE HIGH-TORQUE ELECTRICAL MOTOR UNDER OPERATING CONDITIONS AT LOW TEMPERATURES IN VACUUM
title_full DIAGNOSTICS OF THE HIGH-TORQUE ELECTRICAL MOTOR UNDER OPERATING CONDITIONS AT LOW TEMPERATURES IN VACUUM
title_fullStr DIAGNOSTICS OF THE HIGH-TORQUE ELECTRICAL MOTOR UNDER OPERATING CONDITIONS AT LOW TEMPERATURES IN VACUUM
title_full_unstemmed DIAGNOSTICS OF THE HIGH-TORQUE ELECTRICAL MOTOR UNDER OPERATING CONDITIONS AT LOW TEMPERATURES IN VACUUM
title_short DIAGNOSTICS OF THE HIGH-TORQUE ELECTRICAL MOTOR UNDER OPERATING CONDITIONS AT LOW TEMPERATURES IN VACUUM
title_sort diagnostics of the high torque electrical motor under operating conditions at low temperatures in vacuum
topic high-moment electrical motor
imitation of space
url https://pimi.bntu.by/jour/article/view/143
work_keys_str_mv AT avbyeli diagnosticsofthehightorqueelectricalmotorunderoperatingconditionsatlowtemperaturesinvacuum
AT ankarpovich diagnosticsofthehightorqueelectricalmotorunderoperatingconditionsatlowtemperaturesinvacuum
AT egbilenko diagnosticsofthehightorqueelectricalmotorunderoperatingconditionsatlowtemperaturesinvacuum