Determination of Atenolol and Trimetazidine in Pharmaceutical Tablets and Human Urine Using a High Performance Liquid Chromatography-Photo Diode Array Detection Method
A simple RP-HPLC-PDA method for determination of atenolol (ATN) and trimetazidine (TMZ) in human urine and tablets has been developed. Analytes were separated on a Caltrex BI column (125× 4.0 mm, 5 μm) with 25mM potassium dihydrogen phosphate pH 3.3, methanol, and acetonitrile mobile phases. The PDA...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2019-01-01
|
Series: | International Journal of Analytical Chemistry |
Online Access: | http://dx.doi.org/10.1155/2019/9625849 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832551040981925888 |
---|---|
author | Walaa El-Alfy Omnia A. Ismaiel Magda Y. El-Mammli Abdalla Shalaby |
author_facet | Walaa El-Alfy Omnia A. Ismaiel Magda Y. El-Mammli Abdalla Shalaby |
author_sort | Walaa El-Alfy |
collection | DOAJ |
description | A simple RP-HPLC-PDA method for determination of atenolol (ATN) and trimetazidine (TMZ) in human urine and tablets has been developed. Analytes were separated on a Caltrex BI column (125× 4.0 mm, 5 μm) with 25mM potassium dihydrogen phosphate pH 3.3, methanol, and acetonitrile mobile phases. The PDA detector was operated at 210 nm for TMZ and 225 nm for ATN and the flow rate was 1.0 mL/ min. Linearity was obtained over a concentration range of (1.0-100 μg/mL) for both analytes in standard solutions and the method was successfully applied for determination of target analytes in their pharmaceutical tablets. Excellent linearity was also obtained over concentration ranges of (0.25-25 μg/mL) and (0.5-25 μg/mL) in human urine for TMZ and ATN, respectively. A simple liquid-liquid extraction was applied for urine sample clean-up and a gradient method was used for chromatographic separation. The lower limit of quantitation (LOQ) was 0.99 and 0.60 μg/mL for ATN and TMZ, respectively. The limit of detection (LOD) was 0.30 and 0.18 μg/mL for ATN and TMZ, respectively. Inter- and intraday precision and accuracy for ATN were within ±1.89% in pure form and within ±2.85% in urine samples. Inter- and intraday precision and accuracy for TMZ were within ± 3.99% in pure form and within ± 3.19% in urine samples. |
format | Article |
id | doaj-art-41c7d52a68ad4b6a9617ff3de07c13bd |
institution | Kabale University |
issn | 1687-8760 1687-8779 |
language | English |
publishDate | 2019-01-01 |
publisher | Wiley |
record_format | Article |
series | International Journal of Analytical Chemistry |
spelling | doaj-art-41c7d52a68ad4b6a9617ff3de07c13bd2025-02-03T06:05:04ZengWileyInternational Journal of Analytical Chemistry1687-87601687-87792019-01-01201910.1155/2019/96258499625849Determination of Atenolol and Trimetazidine in Pharmaceutical Tablets and Human Urine Using a High Performance Liquid Chromatography-Photo Diode Array Detection MethodWalaa El-Alfy0Omnia A. Ismaiel1Magda Y. El-Mammli2Abdalla Shalaby3Department of Analytical Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig 44519, EgyptDepartment of Analytical Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig 44519, EgyptDepartment of Analytical Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig 44519, EgyptDepartment of Analytical Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig 44519, EgyptA simple RP-HPLC-PDA method for determination of atenolol (ATN) and trimetazidine (TMZ) in human urine and tablets has been developed. Analytes were separated on a Caltrex BI column (125× 4.0 mm, 5 μm) with 25mM potassium dihydrogen phosphate pH 3.3, methanol, and acetonitrile mobile phases. The PDA detector was operated at 210 nm for TMZ and 225 nm for ATN and the flow rate was 1.0 mL/ min. Linearity was obtained over a concentration range of (1.0-100 μg/mL) for both analytes in standard solutions and the method was successfully applied for determination of target analytes in their pharmaceutical tablets. Excellent linearity was also obtained over concentration ranges of (0.25-25 μg/mL) and (0.5-25 μg/mL) in human urine for TMZ and ATN, respectively. A simple liquid-liquid extraction was applied for urine sample clean-up and a gradient method was used for chromatographic separation. The lower limit of quantitation (LOQ) was 0.99 and 0.60 μg/mL for ATN and TMZ, respectively. The limit of detection (LOD) was 0.30 and 0.18 μg/mL for ATN and TMZ, respectively. Inter- and intraday precision and accuracy for ATN were within ±1.89% in pure form and within ±2.85% in urine samples. Inter- and intraday precision and accuracy for TMZ were within ± 3.99% in pure form and within ± 3.19% in urine samples.http://dx.doi.org/10.1155/2019/9625849 |
spellingShingle | Walaa El-Alfy Omnia A. Ismaiel Magda Y. El-Mammli Abdalla Shalaby Determination of Atenolol and Trimetazidine in Pharmaceutical Tablets and Human Urine Using a High Performance Liquid Chromatography-Photo Diode Array Detection Method International Journal of Analytical Chemistry |
title | Determination of Atenolol and Trimetazidine in Pharmaceutical Tablets and Human Urine Using a High Performance Liquid Chromatography-Photo Diode Array Detection Method |
title_full | Determination of Atenolol and Trimetazidine in Pharmaceutical Tablets and Human Urine Using a High Performance Liquid Chromatography-Photo Diode Array Detection Method |
title_fullStr | Determination of Atenolol and Trimetazidine in Pharmaceutical Tablets and Human Urine Using a High Performance Liquid Chromatography-Photo Diode Array Detection Method |
title_full_unstemmed | Determination of Atenolol and Trimetazidine in Pharmaceutical Tablets and Human Urine Using a High Performance Liquid Chromatography-Photo Diode Array Detection Method |
title_short | Determination of Atenolol and Trimetazidine in Pharmaceutical Tablets and Human Urine Using a High Performance Liquid Chromatography-Photo Diode Array Detection Method |
title_sort | determination of atenolol and trimetazidine in pharmaceutical tablets and human urine using a high performance liquid chromatography photo diode array detection method |
url | http://dx.doi.org/10.1155/2019/9625849 |
work_keys_str_mv | AT walaaelalfy determinationofatenololandtrimetazidineinpharmaceuticaltabletsandhumanurineusingahighperformanceliquidchromatographyphotodiodearraydetectionmethod AT omniaaismaiel determinationofatenololandtrimetazidineinpharmaceuticaltabletsandhumanurineusingahighperformanceliquidchromatographyphotodiodearraydetectionmethod AT magdayelmammli determinationofatenololandtrimetazidineinpharmaceuticaltabletsandhumanurineusingahighperformanceliquidchromatographyphotodiodearraydetectionmethod AT abdallashalaby determinationofatenololandtrimetazidineinpharmaceuticaltabletsandhumanurineusingahighperformanceliquidchromatographyphotodiodearraydetectionmethod |