Method for determination of electromagnetic parameters of submersible induction motors
Positive and energy saving frequency control of submersible asynchronous electric motors demands a research of its work as a part of electrotechnical complexes of installations of electrocentrifugal pumps on the basis of modeling. This approach is oriented to development of ways of identificatio...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
2019-06-01
|
Series: | Омский научный вестник |
Subjects: | |
Online Access: | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/3%20(165)/33-37%20%D0%90%D0%BD%D0%B8%D0%BA%D0%B8%D0%BD%20%D0%92.%20%D0%92.,%20%D0%A5%D0%B0%D0%BC%D0%B8%D1%82%D0%BE%D0%B2%20%D0%A0.%20%D0%9D..pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832569318827622400 |
---|---|
author | V. V. Anikin R. N. Khamitov |
author_facet | V. V. Anikin R. N. Khamitov |
author_sort | V. V. Anikin |
collection | DOAJ |
description | Positive and energy saving frequency control of submersible
asynchronous electric motors demands a research of its
work as a part of electrotechnical complexes of installations
of electrocentrifugal pumps on the basis of modeling. This
approach is oriented to development of ways of identification
of parameters of its equivalent circuits on experimental data. A
research objective is development of a way for determination
of parameters of the equivalent circuit of submersible
asynchronous electric motors with the use of integral of an
attenuation curve of current of a winding of the stator without
additional transition to frequency responses. The research of
a way is conducted on the basis of the developed installation
for identification of parameters of equivalent circuits of submersible asynchronous electric motors. For assessment
of reliability of a way and a technique of identification of
parameters of the equivalent circuit of the submersible electric
motor with integrated conversion of an attenuation curve of
current of the stator of the submersible electric motor the
experiment which shows the greatest discrepancy between
values of parameters of the equivalent circuit — no more than
10 % is made. The developed way of identification of parameters
of equivalent circuits of the submersible postrepair electric
motor, thus, allows to determine operational parameters and
characteristics of the electric motor in conditions of repair
service enterprises. |
format | Article |
id | doaj-art-3d77108879984f96a9ac1d83e66e7ce7 |
institution | Kabale University |
issn | 1813-8225 2541-7541 |
language | English |
publishDate | 2019-06-01 |
publisher | Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education |
record_format | Article |
series | Омский научный вестник |
spelling | doaj-art-3d77108879984f96a9ac1d83e66e7ce72025-02-02T22:20:15ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412019-06-013 (165)333710.25206/1813-8225-2019-165-33-37Method for determination of electromagnetic parameters of submersible induction motorsV. V. Anikin0R. N. Khamitov1https://orcid.org/0000-0001-9876-5471Nizhnevartovsk State UniversityOmsk State Technical UniversityPositive and energy saving frequency control of submersible asynchronous electric motors demands a research of its work as a part of electrotechnical complexes of installations of electrocentrifugal pumps on the basis of modeling. This approach is oriented to development of ways of identification of parameters of its equivalent circuits on experimental data. A research objective is development of a way for determination of parameters of the equivalent circuit of submersible asynchronous electric motors with the use of integral of an attenuation curve of current of a winding of the stator without additional transition to frequency responses. The research of a way is conducted on the basis of the developed installation for identification of parameters of equivalent circuits of submersible asynchronous electric motors. For assessment of reliability of a way and a technique of identification of parameters of the equivalent circuit of the submersible electric motor with integrated conversion of an attenuation curve of current of the stator of the submersible electric motor the experiment which shows the greatest discrepancy between values of parameters of the equivalent circuit — no more than 10 % is made. The developed way of identification of parameters of equivalent circuits of the submersible postrepair electric motor, thus, allows to determine operational parameters and characteristics of the electric motor in conditions of repair service enterprises.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/3%20(165)/33-37%20%D0%90%D0%BD%D0%B8%D0%BA%D0%B8%D0%BD%20%D0%92.%20%D0%92.,%20%D0%A5%D0%B0%D0%BC%D0%B8%D1%82%D0%BE%D0%B2%20%D0%A0.%20%D0%9D..pdfsubmersible asynchronous electric motorequivalent circuitelectromagnetic parameterssurge characteristicscheme of inclusion |
spellingShingle | V. V. Anikin R. N. Khamitov Method for determination of electromagnetic parameters of submersible induction motors Омский научный вестник submersible asynchronous electric motor equivalent circuit electromagnetic parameters surge characteristic scheme of inclusion |
title | Method for determination of electromagnetic parameters of submersible induction motors |
title_full | Method for determination of electromagnetic parameters of submersible induction motors |
title_fullStr | Method for determination of electromagnetic parameters of submersible induction motors |
title_full_unstemmed | Method for determination of electromagnetic parameters of submersible induction motors |
title_short | Method for determination of electromagnetic parameters of submersible induction motors |
title_sort | method for determination of electromagnetic parameters of submersible induction motors |
topic | submersible asynchronous electric motor equivalent circuit electromagnetic parameters surge characteristic scheme of inclusion |
url | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/3%20(165)/33-37%20%D0%90%D0%BD%D0%B8%D0%BA%D0%B8%D0%BD%20%D0%92.%20%D0%92.,%20%D0%A5%D0%B0%D0%BC%D0%B8%D1%82%D0%BE%D0%B2%20%D0%A0.%20%D0%9D..pdf |
work_keys_str_mv | AT vvanikin methodfordeterminationofelectromagneticparametersofsubmersibleinductionmotors AT rnkhamitov methodfordeterminationofelectromagneticparametersofsubmersibleinductionmotors |