Outdoor Performance Assessment of New and Old Photovoltaic Panel Technologies Using a Designed Multi-Photovoltaic Panel Power Measurement System

This paper presents a new multi-photovoltaic panel measurement and analysis system (PPMAS) developed for measurement of atmospheric parameters and generated power of photovoltaic (PV) panels. Designed system presented with an experimental study evaluates performance of four new and four 5-year-old P...

Full description

Saved in:
Bibliographic Details
Main Authors: Mehmet Karabulut, Huseyin Kusetogullari, Sinan Kivrak
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:International Journal of Photoenergy
Online Access:http://dx.doi.org/10.1155/2020/8866412
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832547625890480128
author Mehmet Karabulut
Huseyin Kusetogullari
Sinan Kivrak
author_facet Mehmet Karabulut
Huseyin Kusetogullari
Sinan Kivrak
author_sort Mehmet Karabulut
collection DOAJ
description This paper presents a new multi-photovoltaic panel measurement and analysis system (PPMAS) developed for measurement of atmospheric parameters and generated power of photovoltaic (PV) panels. Designed system presented with an experimental study evaluates performance of four new and four 5-year-old PV panel technologies which are based on polycrystalline (Poly), monocrystalline (Mono), copper indium selenide (CIS), and cadmium telluride (CdTe) in real time, under same atmospheric conditions. The PPMAS system with the PV panels is installed in Yildirim Beyazit University, Ankara Province, in Turkey. The designed PPMAS consists of three different subsystems which are (1) photovoltaic panel measurement subsystem (PPMS), (2) meteorology measurement subsystem (MMS), and (3) data acquisition subsystem (DAS). PPMS is used to measure the power generation for PV panels. MMS involves different types of sensors, and it is designed to determine atmospheric conditions including wind speed, wind direction, outdoor temperature, humidity, ambient light, and panel temperatures. The measured values by PPMS and MMS are stored in a database using DAS subsystem. In order to improve the measurement accuracy, PPMS and MMS are calibrated. This study also focuses on outdoor testing performances of four new and four 5-year-old PV panels. Average monthly panel efficiencies are estimated as 8.46%, 8.11%, 5.65%, and 3.88% for new Mono, new Poly, new CIS, and new CdTe PV panels, respectively. Moreover, average monthly panel efficiencies of old panels are calculated as 8.22%, 7.85%, 5.35%, and 3.63% in the same order. Test results obtained from the experimental system are also statistically examined and discussed to analyze the performance of PV panels in terms of monthly panel efficiencies.
format Article
id doaj-art-3493db0e7c664184b4e5f1c323c117d8
institution Kabale University
issn 1110-662X
1687-529X
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series International Journal of Photoenergy
spelling doaj-art-3493db0e7c664184b4e5f1c323c117d82025-02-03T06:43:50ZengWileyInternational Journal of Photoenergy1110-662X1687-529X2020-01-01202010.1155/2020/88664128866412Outdoor Performance Assessment of New and Old Photovoltaic Panel Technologies Using a Designed Multi-Photovoltaic Panel Power Measurement SystemMehmet Karabulut0Huseyin Kusetogullari1Sinan Kivrak2Department of Electrical and Computer Engineering, Yildirim Beyazit University, Ankara, TurkeyDepartment of Computer Science, Blekinge Institute of Technology, 371 41 Karlskrona, SwedenDepartment of Electrical and Electronic Engineering, Yildirim Beyazit University, Ankara, TurkeyThis paper presents a new multi-photovoltaic panel measurement and analysis system (PPMAS) developed for measurement of atmospheric parameters and generated power of photovoltaic (PV) panels. Designed system presented with an experimental study evaluates performance of four new and four 5-year-old PV panel technologies which are based on polycrystalline (Poly), monocrystalline (Mono), copper indium selenide (CIS), and cadmium telluride (CdTe) in real time, under same atmospheric conditions. The PPMAS system with the PV panels is installed in Yildirim Beyazit University, Ankara Province, in Turkey. The designed PPMAS consists of three different subsystems which are (1) photovoltaic panel measurement subsystem (PPMS), (2) meteorology measurement subsystem (MMS), and (3) data acquisition subsystem (DAS). PPMS is used to measure the power generation for PV panels. MMS involves different types of sensors, and it is designed to determine atmospheric conditions including wind speed, wind direction, outdoor temperature, humidity, ambient light, and panel temperatures. The measured values by PPMS and MMS are stored in a database using DAS subsystem. In order to improve the measurement accuracy, PPMS and MMS are calibrated. This study also focuses on outdoor testing performances of four new and four 5-year-old PV panels. Average monthly panel efficiencies are estimated as 8.46%, 8.11%, 5.65%, and 3.88% for new Mono, new Poly, new CIS, and new CdTe PV panels, respectively. Moreover, average monthly panel efficiencies of old panels are calculated as 8.22%, 7.85%, 5.35%, and 3.63% in the same order. Test results obtained from the experimental system are also statistically examined and discussed to analyze the performance of PV panels in terms of monthly panel efficiencies.http://dx.doi.org/10.1155/2020/8866412
spellingShingle Mehmet Karabulut
Huseyin Kusetogullari
Sinan Kivrak
Outdoor Performance Assessment of New and Old Photovoltaic Panel Technologies Using a Designed Multi-Photovoltaic Panel Power Measurement System
International Journal of Photoenergy
title Outdoor Performance Assessment of New and Old Photovoltaic Panel Technologies Using a Designed Multi-Photovoltaic Panel Power Measurement System
title_full Outdoor Performance Assessment of New and Old Photovoltaic Panel Technologies Using a Designed Multi-Photovoltaic Panel Power Measurement System
title_fullStr Outdoor Performance Assessment of New and Old Photovoltaic Panel Technologies Using a Designed Multi-Photovoltaic Panel Power Measurement System
title_full_unstemmed Outdoor Performance Assessment of New and Old Photovoltaic Panel Technologies Using a Designed Multi-Photovoltaic Panel Power Measurement System
title_short Outdoor Performance Assessment of New and Old Photovoltaic Panel Technologies Using a Designed Multi-Photovoltaic Panel Power Measurement System
title_sort outdoor performance assessment of new and old photovoltaic panel technologies using a designed multi photovoltaic panel power measurement system
url http://dx.doi.org/10.1155/2020/8866412
work_keys_str_mv AT mehmetkarabulut outdoorperformanceassessmentofnewandoldphotovoltaicpaneltechnologiesusingadesignedmultiphotovoltaicpanelpowermeasurementsystem
AT huseyinkusetogullari outdoorperformanceassessmentofnewandoldphotovoltaicpaneltechnologiesusingadesignedmultiphotovoltaicpanelpowermeasurementsystem
AT sinankivrak outdoorperformanceassessmentofnewandoldphotovoltaicpaneltechnologiesusingadesignedmultiphotovoltaicpanelpowermeasurementsystem