Harmonic Current Suppression of Dual Three-Phase Permanent Magnet Synchronous Motor with Improved Proportional-Integral Resonant Controller
The impedance of the harmonic plane in a dual three-phase permanent magnet synchronous motor (DTP-PMSM) is very low, meaning that even small harmonic voltages can induce significant harmonic currents, particularly at the fifth and seventh harmonic frequencies. These harmonic currents can severely de...