FRACTURE ANALYSIS OF MAIN TRANSFORMER EQUIPMENT CLAMP IN NUCLEAR POWER PLANT

Several equipment clamps of main transformer in a nuclear power company were broken. Taking samples from the broken equipment clamps and the same batch of spare equipment clamps, the fracture causes were analyzed through macroscopic inspection, penetrant testing, metallographic analysis, micro morph...