The stand for conducting acceptance tests of asynchronous electric machines by method of mutual loading
Improving the reliability and increasing the operational life of electrical equipment of electric rolling stock is one of the eight directions of scientific and technical development of JSC «Russian Railways» described in the target program «Strategy for the development of railway transport in th...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
2023-09-01
|
Series: | Омский научный вестник |
Subjects: | |
Online Access: | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2023/%E2%84%963%20(187)%20(%D0%9E%D0%9D%D0%92)/77-83%20%D0%91%D1%83%D0%B1%D0%BB%D0%B8%D0%BA%20%D0%90.%20%D0%92.,%20%D0%91%D1%83%D0%B1%D0%BB%D0%B8%D0%BA%20%D0%92.%20%D0%92.,%20%D0%95%D1%81%D0%B8%D0%BD%20%D0%9D.%20%D0%92.,%20%D0%A2%D0%B8%D1%82%D0%B0%D0%BD%D0%B0%D0%BA%D0%BE%D0%B2%20%D0%94.%20%D0%90..pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832548249367478272 |
---|---|
author | A. V. Bublik V. V. Bublik N. V. Yesin D. A. Titanakov |
author_facet | A. V. Bublik V. V. Bublik N. V. Yesin D. A. Titanakov |
author_sort | A. V. Bublik |
collection | DOAJ |
description | Improving the reliability and increasing the operational life of electrical equipment
of electric rolling stock is one of the eight directions of scientific and technical
development of JSC «Russian Railways» described in the target program «Strategy
for the development of railway transport in the Russian Federation until 2030»,
approved by the decree of the Government of the Russian Federation.
The solution to the problem of improving operational reliability is associated with
comprehensive measures that include a wide range of issues aimed at ensuring the
stable operation of rolling stock and its systems.
Reliable operation of electric machines, which depends on the quality of repairs, has
a significant impact on the operational reliability of electric rolling stock. |
format | Article |
id | doaj-art-25d6f533bc8d474a9ebb2d42485b3d25 |
institution | Kabale University |
issn | 1813-8225 2541-7541 |
language | English |
publishDate | 2023-09-01 |
publisher | Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education |
record_format | Article |
series | Омский научный вестник |
spelling | doaj-art-25d6f533bc8d474a9ebb2d42485b3d252025-02-03T06:21:19ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412023-09-013 (187)778310.25206/1813-8225-2023-187-77-83The stand for conducting acceptance tests of asynchronous electric machines by method of mutual loadingA. V. Bublik0V. V. Bublik1N. V. Yesin2D. A. Titanakov3LLC «TPI»Omsk State Transport UniversityOmsk State Transport UniversityOmsk State Transport UniversityImproving the reliability and increasing the operational life of electrical equipment of electric rolling stock is one of the eight directions of scientific and technical development of JSC «Russian Railways» described in the target program «Strategy for the development of railway transport in the Russian Federation until 2030», approved by the decree of the Government of the Russian Federation. The solution to the problem of improving operational reliability is associated with comprehensive measures that include a wide range of issues aimed at ensuring the stable operation of rolling stock and its systems. Reliable operation of electric machines, which depends on the quality of repairs, has a significant impact on the operational reliability of electric rolling stock.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2023/%E2%84%963%20(187)%20(%D0%9E%D0%9D%D0%92)/77-83%20%D0%91%D1%83%D0%B1%D0%BB%D0%B8%D0%BA%20%D0%90.%20%D0%92.,%20%D0%91%D1%83%D0%B1%D0%BB%D0%B8%D0%BA%20%D0%92.%20%D0%92.,%20%D0%95%D1%81%D0%B8%D0%BD%20%D0%9D.%20%D0%92.,%20%D0%A2%D0%B8%D1%82%D0%B0%D0%BD%D0%B0%D0%BA%D0%BE%D0%B2%20%D0%94.%20%D0%90..pdfasynchronous electric machinesmutual load methodfrequency convertersine filteracceptance teststest benches |
spellingShingle | A. V. Bublik V. V. Bublik N. V. Yesin D. A. Titanakov The stand for conducting acceptance tests of asynchronous electric machines by method of mutual loading Омский научный вестник asynchronous electric machines mutual load method frequency converter sine filter acceptance tests test benches |
title | The stand for conducting acceptance tests of asynchronous electric machines by method of mutual loading |
title_full | The stand for conducting acceptance tests of asynchronous electric machines by method of mutual loading |
title_fullStr | The stand for conducting acceptance tests of asynchronous electric machines by method of mutual loading |
title_full_unstemmed | The stand for conducting acceptance tests of asynchronous electric machines by method of mutual loading |
title_short | The stand for conducting acceptance tests of asynchronous electric machines by method of mutual loading |
title_sort | stand for conducting acceptance tests of asynchronous electric machines by method of mutual loading |
topic | asynchronous electric machines mutual load method frequency converter sine filter acceptance tests test benches |
url | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2023/%E2%84%963%20(187)%20(%D0%9E%D0%9D%D0%92)/77-83%20%D0%91%D1%83%D0%B1%D0%BB%D0%B8%D0%BA%20%D0%90.%20%D0%92.,%20%D0%91%D1%83%D0%B1%D0%BB%D0%B8%D0%BA%20%D0%92.%20%D0%92.,%20%D0%95%D1%81%D0%B8%D0%BD%20%D0%9D.%20%D0%92.,%20%D0%A2%D0%B8%D1%82%D0%B0%D0%BD%D0%B0%D0%BA%D0%BE%D0%B2%20%D0%94.%20%D0%90..pdf |
work_keys_str_mv | AT avbublik thestandforconductingacceptancetestsofasynchronouselectricmachinesbymethodofmutualloading AT vvbublik thestandforconductingacceptancetestsofasynchronouselectricmachinesbymethodofmutualloading AT nvyesin thestandforconductingacceptancetestsofasynchronouselectricmachinesbymethodofmutualloading AT datitanakov thestandforconductingacceptancetestsofasynchronouselectricmachinesbymethodofmutualloading AT avbublik standforconductingacceptancetestsofasynchronouselectricmachinesbymethodofmutualloading AT vvbublik standforconductingacceptancetestsofasynchronouselectricmachinesbymethodofmutualloading AT nvyesin standforconductingacceptancetestsofasynchronouselectricmachinesbymethodofmutualloading AT datitanakov standforconductingacceptancetestsofasynchronouselectricmachinesbymethodofmutualloading |