Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels

The article shows results of processing of data about deviations of supply voltage levels in electric networks of 0,38 KV of the Omsk State Technical University, obtained within the limits of obligatory energetic examination. At given probability value for each measurement point, value of deviati...

Full description

Saved in:
Bibliographic Details
Main Authors: А. V. Ded, S. P. Sikorskiy, I. B. Daniukov
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2018-04-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/55-59%20%D0%94%D0%B5%D0%B4%20%D0%90.%20%D0%92.,%20%D0%A1%D0%B8%D0%BA%D0%BE%D1%80%D1%81%D0%BA%D0%B8%D0%B9%20%D0%A1.%20%D0%9F.,%20%D0%94%D0%B0%D0%BD%D1%8E%D0%BA%D0%BE%D0%B2%20%D0%98.%20%D0%91..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832568827847639040
author А. V. Ded
S. P. Sikorskiy
I. B. Daniukov
author_facet А. V. Ded
S. P. Sikorskiy
I. B. Daniukov
author_sort А. V. Ded
collection DOAJ
description The article shows results of processing of data about deviations of supply voltage levels in electric networks of 0,38 KV of the Omsk State Technical University, obtained within the limits of obligatory energetic examination. At given probability value for each measurement point, value of deviation of voltages of each of phases from nominal value is calculated. It has been found that the average value of deviation of the supply voltage level does not exceed for each of the phases of the values of 7 %, which is less than maximum permissible value of 10 % of set GOST.
format Article
id doaj-art-256ab2c2e6b74a8cbe8622fa470430f9
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2018-04-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-256ab2c2e6b74a8cbe8622fa470430f92025-02-03T00:12:04ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412018-04-012 (158)555910.25206/1813-8225-2018-158-55-59Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levelsА. V. Ded0S. P. Sikorskiy1I. B. Daniukov2Omsk State Technical UniversityOmsk State Technical UniversityOmsk State Technical UniversityThe article shows results of processing of data about deviations of supply voltage levels in electric networks of 0,38 KV of the Omsk State Technical University, obtained within the limits of obligatory energetic examination. At given probability value for each measurement point, value of deviation of voltages of each of phases from nominal value is calculated. It has been found that the average value of deviation of the supply voltage level does not exceed for each of the phases of the values of 7 %, which is less than maximum permissible value of 10 % of set GOST.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/55-59%20%D0%94%D0%B5%D0%B4%20%D0%90.%20%D0%92.,%20%D0%A1%D0%B8%D0%BA%D0%BE%D1%80%D1%81%D0%BA%D0%B8%D0%B9%20%D0%A1.%20%D0%9F.,%20%D0%94%D0%B0%D0%BD%D1%8E%D0%BA%D0%BE%D0%B2%20%D0%98.%20%D0%91..pdfquality of electric energydeviation of voltageasymmetryquality characteristicsquality control of electric energy
spellingShingle А. V. Ded
S. P. Sikorskiy
I. B. Daniukov
Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels
Омский научный вестник
quality of electric energy
deviation of voltage
asymmetry
quality characteristics
quality control of electric energy
title Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels
title_full Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels
title_fullStr Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels
title_full_unstemmed Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels
title_short Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels
title_sort processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels
topic quality of electric energy
deviation of voltage
asymmetry
quality characteristics
quality control of electric energy
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/55-59%20%D0%94%D0%B5%D0%B4%20%D0%90.%20%D0%92.,%20%D0%A1%D0%B8%D0%BA%D0%BE%D1%80%D1%81%D0%BA%D0%B8%D0%B9%20%D0%A1.%20%D0%9F.,%20%D0%94%D0%B0%D0%BD%D1%8E%D0%BA%D0%BE%D0%B2%20%D0%98.%20%D0%91..pdf
work_keys_str_mv AT avded processingofdataofexperimentalmeasurementsofelectricpowerqualitycharacteristicsonexampleofvoltagedeviationlevels
AT spsikorskiy processingofdataofexperimentalmeasurementsofelectricpowerqualitycharacteristicsonexampleofvoltagedeviationlevels
AT ibdaniukov processingofdataofexperimentalmeasurementsofelectricpowerqualitycharacteristicsonexampleofvoltagedeviationlevels