Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels
The article shows results of processing of data about deviations of supply voltage levels in electric networks of 0,38 KV of the Omsk State Technical University, obtained within the limits of obligatory energetic examination. At given probability value for each measurement point, value of deviati...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
2018-04-01
|
Series: | Омский научный вестник |
Subjects: | |
Online Access: | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/55-59%20%D0%94%D0%B5%D0%B4%20%D0%90.%20%D0%92.,%20%D0%A1%D0%B8%D0%BA%D0%BE%D1%80%D1%81%D0%BA%D0%B8%D0%B9%20%D0%A1.%20%D0%9F.,%20%D0%94%D0%B0%D0%BD%D1%8E%D0%BA%D0%BE%D0%B2%20%D0%98.%20%D0%91..pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832568827847639040 |
---|---|
author | А. V. Ded S. P. Sikorskiy I. B. Daniukov |
author_facet | А. V. Ded S. P. Sikorskiy I. B. Daniukov |
author_sort | А. V. Ded |
collection | DOAJ |
description | The article shows results of processing of data about deviations
of supply voltage levels in electric networks of 0,38 KV of the Omsk State Technical University, obtained within the limits of
obligatory energetic examination. At given probability value for
each measurement point, value of deviation of voltages of each of
phases from nominal value is calculated. It has been found that
the average value of deviation of the supply voltage level does not
exceed for each of the phases of the values of 7 %, which is less
than maximum permissible value of 10 % of set GOST. |
format | Article |
id | doaj-art-256ab2c2e6b74a8cbe8622fa470430f9 |
institution | Kabale University |
issn | 1813-8225 2541-7541 |
language | English |
publishDate | 2018-04-01 |
publisher | Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education |
record_format | Article |
series | Омский научный вестник |
spelling | doaj-art-256ab2c2e6b74a8cbe8622fa470430f92025-02-03T00:12:04ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412018-04-012 (158)555910.25206/1813-8225-2018-158-55-59Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levelsА. V. Ded0S. P. Sikorskiy1I. B. Daniukov2Omsk State Technical UniversityOmsk State Technical UniversityOmsk State Technical UniversityThe article shows results of processing of data about deviations of supply voltage levels in electric networks of 0,38 KV of the Omsk State Technical University, obtained within the limits of obligatory energetic examination. At given probability value for each measurement point, value of deviation of voltages of each of phases from nominal value is calculated. It has been found that the average value of deviation of the supply voltage level does not exceed for each of the phases of the values of 7 %, which is less than maximum permissible value of 10 % of set GOST.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/55-59%20%D0%94%D0%B5%D0%B4%20%D0%90.%20%D0%92.,%20%D0%A1%D0%B8%D0%BA%D0%BE%D1%80%D1%81%D0%BA%D0%B8%D0%B9%20%D0%A1.%20%D0%9F.,%20%D0%94%D0%B0%D0%BD%D1%8E%D0%BA%D0%BE%D0%B2%20%D0%98.%20%D0%91..pdfquality of electric energydeviation of voltageasymmetryquality characteristicsquality control of electric energy |
spellingShingle | А. V. Ded S. P. Sikorskiy I. B. Daniukov Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels Омский научный вестник quality of electric energy deviation of voltage asymmetry quality characteristics quality control of electric energy |
title | Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels |
title_full | Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels |
title_fullStr | Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels |
title_full_unstemmed | Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels |
title_short | Processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels |
title_sort | processing of data of experimental measurements of electric power quality characteristics on example of voltage deviation levels |
topic | quality of electric energy deviation of voltage asymmetry quality characteristics quality control of electric energy |
url | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/55-59%20%D0%94%D0%B5%D0%B4%20%D0%90.%20%D0%92.,%20%D0%A1%D0%B8%D0%BA%D0%BE%D1%80%D1%81%D0%BA%D0%B8%D0%B9%20%D0%A1.%20%D0%9F.,%20%D0%94%D0%B0%D0%BD%D1%8E%D0%BA%D0%BE%D0%B2%20%D0%98.%20%D0%91..pdf |
work_keys_str_mv | AT avded processingofdataofexperimentalmeasurementsofelectricpowerqualitycharacteristicsonexampleofvoltagedeviationlevels AT spsikorskiy processingofdataofexperimentalmeasurementsofelectricpowerqualitycharacteristicsonexampleofvoltagedeviationlevels AT ibdaniukov processingofdataofexperimentalmeasurementsofelectricpowerqualitycharacteristicsonexampleofvoltagedeviationlevels |