EXPERIMENTAL RESEARCH OF FRACTURE TOUGHNESS ON NEW ROTOR STEEL FW2 AT ELEVATED TEMPERATURE

The multi-specimen method and the normalization method and the elastic unloading compliance method were used to test the high-temperature fracture toughness of 630℃ on new rotor steel FW2. The multi-specimen method and the normalization method have obtained valid high-temperature fracture toughness...

Full description

Saved in:
Bibliographic Details
Main Authors: WU HaiLi, SUN LinGen
Format: Article
Language:zho
Published: Editorial Office of Journal of Mechanical Strength 2022-01-01
Series:Jixie qiangdu
Subjects:
Online Access:http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2022.01.031