Performance comparison of cooling systems using R410a and RE170 as working fluids at various condensing temperature

In addition to being used as a fuel and propellant, dimethyl ether (RE170) can also be used as an environmentally friendly refrigerant. Apart from having zero ozone depletion potential (ODP), this compound also has a very low global warming potential (GWP), making it safe for the environment. This s...

Full description

Saved in:
Bibliographic Details
Main Authors: Setyawan Andriyanto, Mitrakusuma Windy H., Simbolon Luga M.
Format: Article
Language:English
Published: EDP Sciences 2025-01-01
Series:BIO Web of Conferences
Online Access:https://www.bio-conferences.org/articles/bioconf/pdf/2025/06/bioconf_10thiccc_08006.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832098580142227456
author Setyawan Andriyanto
Mitrakusuma Windy H.
Simbolon Luga M.
author_facet Setyawan Andriyanto
Mitrakusuma Windy H.
Simbolon Luga M.
author_sort Setyawan Andriyanto
collection DOAJ
description In addition to being used as a fuel and propellant, dimethyl ether (RE170) can also be used as an environmentally friendly refrigerant. Apart from having zero ozone depletion potential (ODP), this compound also has a very low global warming potential (GWP), making it safe for the environment. This study aims to compare the performance of refrigeration machines using RE170 and R410, which has long been used as a refrigerant in air conditioning systems. The study was conducted at various evaporation and condensation temperatures. The results showed that RE170 does have a lower cooling capacity, about 41.5% of the cooling capacity of R410A. However, the power required on the system with RE170 is very low, which is only about 35.5% compared to the power required by the system with R410. As a result, the system with RE170 has 16.9% better energy efficiency. Thus, RE170 is not only environmentally friendly but also energy efficient. Another important finding of this study is that RE170 is superior to R410A in terms of energy efficiency at high condensing temperature.
format Article
id doaj-art-139f81933f6e4ca8a27b8638b61cc9f8
institution Kabale University
issn 2117-4458
language English
publishDate 2025-01-01
publisher EDP Sciences
record_format Article
series BIO Web of Conferences
spelling doaj-art-139f81933f6e4ca8a27b8638b61cc9f82025-02-05T10:43:24ZengEDP SciencesBIO Web of Conferences2117-44582025-01-011550800610.1051/bioconf/202515508006bioconf_10thiccc_08006Performance comparison of cooling systems using R410a and RE170 as working fluids at various condensing temperatureSetyawan Andriyanto0Mitrakusuma Windy H.1Simbolon Luga M.2Department of Refrigeration and Air Conditioning Engineering, Politeknik Negeri BandungDepartment of Refrigeration and Air Conditioning Engineering, Politeknik Negeri BandungDepartment of Refrigeration and Air Conditioning Engineering, Politeknik Negeri BandungIn addition to being used as a fuel and propellant, dimethyl ether (RE170) can also be used as an environmentally friendly refrigerant. Apart from having zero ozone depletion potential (ODP), this compound also has a very low global warming potential (GWP), making it safe for the environment. This study aims to compare the performance of refrigeration machines using RE170 and R410, which has long been used as a refrigerant in air conditioning systems. The study was conducted at various evaporation and condensation temperatures. The results showed that RE170 does have a lower cooling capacity, about 41.5% of the cooling capacity of R410A. However, the power required on the system with RE170 is very low, which is only about 35.5% compared to the power required by the system with R410. As a result, the system with RE170 has 16.9% better energy efficiency. Thus, RE170 is not only environmentally friendly but also energy efficient. Another important finding of this study is that RE170 is superior to R410A in terms of energy efficiency at high condensing temperature.https://www.bio-conferences.org/articles/bioconf/pdf/2025/06/bioconf_10thiccc_08006.pdf
spellingShingle Setyawan Andriyanto
Mitrakusuma Windy H.
Simbolon Luga M.
Performance comparison of cooling systems using R410a and RE170 as working fluids at various condensing temperature
BIO Web of Conferences
title Performance comparison of cooling systems using R410a and RE170 as working fluids at various condensing temperature
title_full Performance comparison of cooling systems using R410a and RE170 as working fluids at various condensing temperature
title_fullStr Performance comparison of cooling systems using R410a and RE170 as working fluids at various condensing temperature
title_full_unstemmed Performance comparison of cooling systems using R410a and RE170 as working fluids at various condensing temperature
title_short Performance comparison of cooling systems using R410a and RE170 as working fluids at various condensing temperature
title_sort performance comparison of cooling systems using r410a and re170 as working fluids at various condensing temperature
url https://www.bio-conferences.org/articles/bioconf/pdf/2025/06/bioconf_10thiccc_08006.pdf
work_keys_str_mv AT setyawanandriyanto performancecomparisonofcoolingsystemsusingr410aandre170asworkingfluidsatvariouscondensingtemperature
AT mitrakusumawindyh performancecomparisonofcoolingsystemsusingr410aandre170asworkingfluidsatvariouscondensingtemperature
AT simbolonlugam performancecomparisonofcoolingsystemsusingr410aandre170asworkingfluidsatvariouscondensingtemperature