Stress intensity factor solutions for CTS mixed mode specimen

The Compact Tension Shear (CTS) specimen is used to study fracture and fatigue under mixed mode I/II loading conditions. The K solution available in literature was developed for fracture studies and does not consider the effect of crack deflection. The aim of present work is to develop KI and KII em...

Full description

Saved in:
Bibliographic Details
Main Authors: F.V. Antunes, R. Branco, J.A.M. Ferreira, L.P. Borrego
Format: Article
Language:English
Published: Gruppo Italiano Frattura 2019-04-01
Series:Fracture and Structural Integrity
Subjects:
Online Access:https://www.fracturae.com/index.php/fis/article/view/2210/2486