Comparative analysis of the performance of Shingle and Standard photovoltaic technologies in the environmental conditions of El Jadida

The objective of this paper is to evaluate the performance of two solar interconnection technologies, shingle and standard, under the specific operational conditions of the city of El Jadida, Morocco. We studied Dualsun PV modules, using shingle technology, and Almaden PV modules, based on standard...

Full description

Saved in:
Bibliographic Details
Main Authors: El Alami Yassine, Zohal Bouchaib, Bendaoud Rachid, Rhiat Mohammed, Rabhi Abdelhamid, Benhala Bachir, Hirech Kamal, Baghaz Elhadi
Format: Article
Language:English
Published: EDP Sciences 2025-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/01/e3sconf_icegc2024_00010.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832098576737501184
author El Alami Yassine
Zohal Bouchaib
Bendaoud Rachid
Rhiat Mohammed
Rabhi Abdelhamid
Benhala Bachir
Hirech Kamal
Baghaz Elhadi
author_facet El Alami Yassine
Zohal Bouchaib
Bendaoud Rachid
Rhiat Mohammed
Rabhi Abdelhamid
Benhala Bachir
Hirech Kamal
Baghaz Elhadi
author_sort El Alami Yassine
collection DOAJ
description The objective of this paper is to evaluate the performance of two solar interconnection technologies, shingle and standard, under the specific operational conditions of the city of El Jadida, Morocco. We studied Dualsun PV modules, using shingle technology, and Almaden PV modules, based on standard technology. Performance parameters such as module temperature, efficiency and performance ratio were measured and analyzed. The results reveal that the temperature of the module using shingle technology (Dualsun PV module) is lower than that of the modules using standard technology (Almaden PV module), leading to better performance for the Dualsun PV module. In addition, the difference between the electrical efficiency of the Almaden PV module and the values provided by the manufacturer is 14.65%, while for the Dualsun module the largest difference is 12.71%. In addition, the Dualsun module has the highest average performance Ratio (90.5%), compared with 90% for the Almaden module.
format Article
id doaj-art-0c6d9e41ae064224b842197e677b216e
institution Kabale University
issn 2267-1242
language English
publishDate 2025-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj-art-0c6d9e41ae064224b842197e677b216e2025-02-05T10:46:25ZengEDP SciencesE3S Web of Conferences2267-12422025-01-016010001010.1051/e3sconf/202560100010e3sconf_icegc2024_00010Comparative analysis of the performance of Shingle and Standard photovoltaic technologies in the environmental conditions of El JadidaEl Alami Yassine0Zohal Bouchaib1Bendaoud Rachid2Rhiat Mohammed3Rabhi Abdelhamid4Benhala Bachir5Hirech Kamal6Baghaz Elhadi7Laboratory of Electronics, Instrumentation and Energetic FS, Chouaïb Doukkali UniversityLaboratory of Electronics, Instrumentation and Energetic FS, Chouaïb Doukkali UniversityLaboratory of Electronics, Instrumentation and Energetic FS, Chouaïb Doukkali UniversityHigher School of Technology - LGEM Laboratory, Mohammed First UniversityLaboratory of Modulization, Information and Systems, University of Picardie Jules VerneFaculty of Sciences Dhar El Mahraz Fez, Sidi Mohamed Ben Abdellah UniversityHigher School of Technology - LGEM Laboratory, Mohammed First UniversityLaboratory of Electronics, Instrumentation and Energetic FS, Chouaïb Doukkali UniversityThe objective of this paper is to evaluate the performance of two solar interconnection technologies, shingle and standard, under the specific operational conditions of the city of El Jadida, Morocco. We studied Dualsun PV modules, using shingle technology, and Almaden PV modules, based on standard technology. Performance parameters such as module temperature, efficiency and performance ratio were measured and analyzed. The results reveal that the temperature of the module using shingle technology (Dualsun PV module) is lower than that of the modules using standard technology (Almaden PV module), leading to better performance for the Dualsun PV module. In addition, the difference between the electrical efficiency of the Almaden PV module and the values provided by the manufacturer is 14.65%, while for the Dualsun module the largest difference is 12.71%. In addition, the Dualsun module has the highest average performance Ratio (90.5%), compared with 90% for the Almaden module.https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/01/e3sconf_icegc2024_00010.pdf
spellingShingle El Alami Yassine
Zohal Bouchaib
Bendaoud Rachid
Rhiat Mohammed
Rabhi Abdelhamid
Benhala Bachir
Hirech Kamal
Baghaz Elhadi
Comparative analysis of the performance of Shingle and Standard photovoltaic technologies in the environmental conditions of El Jadida
E3S Web of Conferences
title Comparative analysis of the performance of Shingle and Standard photovoltaic technologies in the environmental conditions of El Jadida
title_full Comparative analysis of the performance of Shingle and Standard photovoltaic technologies in the environmental conditions of El Jadida
title_fullStr Comparative analysis of the performance of Shingle and Standard photovoltaic technologies in the environmental conditions of El Jadida
title_full_unstemmed Comparative analysis of the performance of Shingle and Standard photovoltaic technologies in the environmental conditions of El Jadida
title_short Comparative analysis of the performance of Shingle and Standard photovoltaic technologies in the environmental conditions of El Jadida
title_sort comparative analysis of the performance of shingle and standard photovoltaic technologies in the environmental conditions of el jadida
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/01/e3sconf_icegc2024_00010.pdf
work_keys_str_mv AT elalamiyassine comparativeanalysisoftheperformanceofshingleandstandardphotovoltaictechnologiesintheenvironmentalconditionsofeljadida
AT zohalbouchaib comparativeanalysisoftheperformanceofshingleandstandardphotovoltaictechnologiesintheenvironmentalconditionsofeljadida
AT bendaoudrachid comparativeanalysisoftheperformanceofshingleandstandardphotovoltaictechnologiesintheenvironmentalconditionsofeljadida
AT rhiatmohammed comparativeanalysisoftheperformanceofshingleandstandardphotovoltaictechnologiesintheenvironmentalconditionsofeljadida
AT rabhiabdelhamid comparativeanalysisoftheperformanceofshingleandstandardphotovoltaictechnologiesintheenvironmentalconditionsofeljadida
AT benhalabachir comparativeanalysisoftheperformanceofshingleandstandardphotovoltaictechnologiesintheenvironmentalconditionsofeljadida
AT hirechkamal comparativeanalysisoftheperformanceofshingleandstandardphotovoltaictechnologiesintheenvironmentalconditionsofeljadida
AT baghazelhadi comparativeanalysisoftheperformanceofshingleandstandardphotovoltaictechnologiesintheenvironmentalconditionsofeljadida