The Integral Test Facility Karlstein

The Integral Test Facility Karlstein (INKA) test facility was designed and erected to test the performance of the passive safety systems of KERENA, the new AREVA Boiling Water Reactor design. The experimental program included single component/system tests of the Emergency Condenser, the Containment...

Full description

Saved in:
Bibliographic Details
Main Authors: Stephan Leyer, Michael Wich
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:Science and Technology of Nuclear Installations
Online Access:http://dx.doi.org/10.1155/2012/439374