Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum

The developed method used three enzymes comprised of cholesterol esterase, cholesterol oxidase, and peroxidase for fabrication of amperometric biosensor in order to determine total cholesterol in serum samples. Gold nanoparticles (AuNPs) and carboxylated multiwall carbon nanotubes (cMWCNTs) were use...

Full description

Saved in:
Bibliographic Details
Main Authors: Kusum Lata, Vikas Dhull, Vikas Hooda
Format: Article
Language:English
Published: Wiley 2016-01-01
Series:Biochemistry Research International
Online Access:http://dx.doi.org/10.1155/2016/1545206
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832567911207665664
author Kusum Lata
Vikas Dhull
Vikas Hooda
author_facet Kusum Lata
Vikas Dhull
Vikas Hooda
author_sort Kusum Lata
collection DOAJ
description The developed method used three enzymes comprised of cholesterol esterase, cholesterol oxidase, and peroxidase for fabrication of amperometric biosensor in order to determine total cholesterol in serum samples. Gold nanoparticles (AuNPs) and carboxylated multiwall carbon nanotubes (cMWCNTs) were used to design core of working electrode, having covalently immobilized ChO, ChE, and HRP. Polyacrylamide layer was finally coated on working electrode in order to prevent enzyme leaching. Chemically synthesised Au nanoparticles were subjected to transmission electron microscopy (TEM) for analysing the shape and size of the particles. Working electrode was subjected to FTIR and XRD. The combined action of AuNP and c-MWCNT showed enhancement in electrocatalytic activity at a very low potential of 0.27 V. The pH 7, temperature 40°C, and response time of 20 seconds, respectively, were observed. The biosensor shows a broad linear range from 0.5 mg/dL to 250 mg/dL (0.01 mM–5.83 mM) with minimum detection limit being 0.5 mg/dL (0.01 mM). The biosensor showed reusability of more than 45 times and was stable for 60 days. The biosensor was successfully tested for determining total cholesterol in serum samples amperometrically with no significant interference by serum components.
format Article
id doaj-art-02a30b38afab402d96c8eded07b8d461
institution Kabale University
issn 2090-2247
2090-2255
language English
publishDate 2016-01-01
publisher Wiley
record_format Article
series Biochemistry Research International
spelling doaj-art-02a30b38afab402d96c8eded07b8d4612025-02-03T01:00:09ZengWileyBiochemistry Research International2090-22472090-22552016-01-01201610.1155/2016/15452061545206Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in SerumKusum Lata0Vikas Dhull1Vikas Hooda2Centre for Biotechnology, Maharshi Dayanand University, Rohtak, Haryana 124001, IndiaDepartment of Bio & Nano Technology, Guru Jambheshwar University of Science & Technology, Hisar, Haryana 125001, IndiaCentre for Biotechnology, Maharshi Dayanand University, Rohtak, Haryana 124001, IndiaThe developed method used three enzymes comprised of cholesterol esterase, cholesterol oxidase, and peroxidase for fabrication of amperometric biosensor in order to determine total cholesterol in serum samples. Gold nanoparticles (AuNPs) and carboxylated multiwall carbon nanotubes (cMWCNTs) were used to design core of working electrode, having covalently immobilized ChO, ChE, and HRP. Polyacrylamide layer was finally coated on working electrode in order to prevent enzyme leaching. Chemically synthesised Au nanoparticles were subjected to transmission electron microscopy (TEM) for analysing the shape and size of the particles. Working electrode was subjected to FTIR and XRD. The combined action of AuNP and c-MWCNT showed enhancement in electrocatalytic activity at a very low potential of 0.27 V. The pH 7, temperature 40°C, and response time of 20 seconds, respectively, were observed. The biosensor shows a broad linear range from 0.5 mg/dL to 250 mg/dL (0.01 mM–5.83 mM) with minimum detection limit being 0.5 mg/dL (0.01 mM). The biosensor showed reusability of more than 45 times and was stable for 60 days. The biosensor was successfully tested for determining total cholesterol in serum samples amperometrically with no significant interference by serum components.http://dx.doi.org/10.1155/2016/1545206
spellingShingle Kusum Lata
Vikas Dhull
Vikas Hooda
Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum
Biochemistry Research International
title Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum
title_full Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum
title_fullStr Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum
title_full_unstemmed Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum
title_short Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum
title_sort fabrication and optimization of che cho hrp aunps c mwcnts based silver electrode for determining total cholesterol in serum
url http://dx.doi.org/10.1155/2016/1545206
work_keys_str_mv AT kusumlata fabricationandoptimizationofchechohrpaunpscmwcntsbasedsilverelectrodefordeterminingtotalcholesterolinserum
AT vikasdhull fabricationandoptimizationofchechohrpaunpscmwcntsbasedsilverelectrodefordeterminingtotalcholesterolinserum
AT vikashooda fabricationandoptimizationofchechohrpaunpscmwcntsbasedsilverelectrodefordeterminingtotalcholesterolinserum