Showing 141 - 160 results of 536 for search 'detection diffraction', query time: 0.10s Refine Results
  1. 141

    Mature green tea leaves derived CDs as both reducing agent and stabilizer for synthesis of CD-AgNPs composite for Hg(II) ions detection by Swagata Patra, Animes K. Golder, Ramagopal V.S. Uppaluri

    Published 2025-01-01
    “…In summary, a highly sensitive system for Hg(II) detection has been confirmed and the interference effect has been insignificant with respect to other metal ions.…”
    Get full text
    Article
  2. 142

    Nitrogen-doped carbon dots from Brahmi (Bacopa monnieri): Metal-free probe for efficient detection of metal pollutants and methylene blue dye degradation by Soman Kondetharayil, Kanagaraj Kuppusamy, Senthilkumar Nangan, Rajendran Saravanan, Faraj Turki Kh., Alrefaei Abdulwahed Fahad, Thirumalaivasan Natesan, Sundaram Thanigaivel, Roy Arpita, Verma Rajan, Thomas Sabu, Gopi Sreeraj, Lackner Maximilian

    Published 2025-07-01
    “…The NCDs showed a high quantum yield of 15.7%, and demonstrated significant fluorescence quenching in the presence of Fe³⁺ and Ni²⁺ ions, with detection limits of 1.46 and 3.19 µmol·L−1, respectively. …”
    Get full text
    Article
  3. 143
  4. 144
  5. 145

    Single chip simultaneous chiral and achiral imaging based on high efficiency 3D plasmonic metalens by Sun Ti, Yang Xing, Xu Feng, Wang Chinhua

    Published 2023-07-01
    “…We propose and experimentally demonstrate a single chip metasurface for simultaneous chiral and achiral imaging and polarimetric detecting using a high efficiency three dimensional plasmonic metalens (3D-PM) with capability of designed separation of different circular polarizations. …”
    Get full text
    Article
  6. 146

    An Ultrasensitive Ethanol Gas Sensor Based on a Dual-Nanoparticle In<sub>2</sub>O<sub>3</sub>/SnO<sub>2</sub> Composite by Cheng Zhang, Ze Zhang, Yao Tian, Lingmin Yu, Hairong Wang

    Published 2024-12-01
    “…The ultrasensitive response to ethanol can be attributed to the faster electron migration rate and the increase in oxygen-absorbing sites caused by the n-n heterojunction in the nanocomposite. Due to its low detection limit, good repeatability, and relatively high responses in high humidity, this sensor has a potential application in exhaled breath detection.…”
    Get full text
    Article
  7. 147

    Study of the application prospects of film detectors for estimation of α-radiation density by Dana S. Yerimbetova, Marina Konuhova, Artem L. Kozlovskiy, Umitali N. Tuichiyev

    Published 2025-02-01
    “…During the experiments, good convergence of the results of structural changes determined by optical spectroscopy and X-ray diffraction methods was established. These changes are caused by the processes of interaction of α-particles with a polymer detector, characterized by deformation distortion of the molecular chains of the polymer, leading to the formation of defects that affect changes in optical and electron density. …”
    Get full text
    Article
  8. 148

    Combination of Cu-BTC- and FeCo-MOF-Derived Carbon Enhanced Molecularly Imprinted Electrochemical Sensor for Highly Sensitive and Selective Detection of Benomyl in Fruits and Veget... by Lili Chen, Shuya Xue, Xin Li, Linbo Deng, Jiapeng Li, Jing Zhou, Yansha Gao, Xuemin Duan, Limin Lu

    Published 2025-04-01
    “…In this work, a high-performance molecularly imprinted electrochemical sensor based on the composite of Cu-BTC- and FeCo-ZIF-derived N-doped carbon (FeCo@NC), synthesized by pyrolysis and electrodeposition, was developed for Benomyl (BN) detection. The materials were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). …”
    Get full text
    Article
  9. 149

    High-Performance ZIF-7@PANI Electrochemical Sensor for Simultaneous Trace Cadmium and Lead Detection in Water Samples: A Box–Behnken Design Optimization Approach by Sondes Guesmi, Nashwan H. Ali, Nadhem Missaoui, Zouhaier Aloui, Chama Mabrouk, Carlos Castilla Martinez, Fraj Echouchene, Houcine Barhoumi, Nicole Jaffrezic-Renault, Hamza Kahri

    Published 2025-02-01
    “…This study presents the development of an innovative electrochemical sensor for the simultaneous detection of cadmium (Cd<sup>2+</sup>) and lead (Pb<sup>2+</sup>) ions in environmental samples. …”
    Get full text
    Article
  10. 150

    Multi-label classification with deep learning techniques applied to the B-Scan images of GPR by El Karakhi, Soukayna, Reineix, Alain, Guiffaut, Christophe

    Published 2024-09-01
    “…It has the advantage of allowing detection by a non-destructive technique. The principle for time domain GPR consists in emitting electromagnetic pulses in the ground, these one are then diffracted by the targets to be detected. …”
    Get full text
    Article
  11. 151
  12. 152

    Fabrication and electrocatalytic performance of CoW11CpFe@Cu-BTC/MWCNTs-COOH modified glassy carbon electrode for simultaneous detection of dopamine and uric acid by Somayeh Kochebaghi, Somayeh Dianat

    Published 2025-06-01
    “…Simultaneous detection of dopamine (DA) and uric acid (UA) is clinically important but challenging due to their similar properties, which often lead to poor sensitivity and specificity in traditional diagnostic methods.To address this, the study presents a novel hybrid nanocomposite-POM@MOF/MWCNTs-COOH-engineered for the selective and sensitive detection of both biomarkers. …”
    Get full text
    Article
  13. 153

    Electrochemical Sensor Based on DNA Aptamers Immobilized on V<sub>2</sub>O<sub>5</sub>/rGO Nanocomposite for the Sensitive Detection of Hg(II) by Mahesh A. Takte, Shubham S. Patil, Akash V. Fulari, Tibor Hianik, Mahendra D. Shirsat

    Published 2025-04-01
    “…The aptasensor exhibited excellent sensitivity and selectivity toward Hg(II) detection, with a limit of detection (LOD) of 5.57 nM, which is below the maximum permissible limit established by WHO for rivers (30 nM). …”
    Get full text
    Article
  14. 154

    Innovative MOF-enhanced electroanalytical approach for sensitive sunitinib malate detection in renal carcinoma patients using CuO/lanthanum MOF-modified carbon paste electrode by Azza H. Rageh, Mohamed I. Said, Asmaa Abdeltawab, Fatma A.M. Abdel-aal

    Published 2025-08-01
    “…The main aim of this work is to develop a highly sensitive, selective, and cost-effective electrochemical sensor for detecting sunitinib malate (SUN) in serum samples collected from renal cancer patients. …”
    Get full text
    Article
  15. 155

    Preliminary mechanistic insights into the detection of ethanol vapour using MnO2 NRs-CNPs-poly-4-(vinylpyridine) based solid-state sensor operating at room temperature by Lesego Malepe, Derek Tantoh Ndinteh, Patrick Ndungu, Messai Adenew Mamo

    Published 2025-01-01
    “…In this work, we present manganese dioxide nanorods (MnO2 NRs) prepared via hydrothermal synthetic route, carbon soot (CNPs) prepared via pyrolysis of lighthouse candle, and poly-4-vinylpyridine (P4VP) composite for the detection of ethanol vapour at room temperature. MnO2, CNPs, P4VP, and MnO2 NRs-CNPs-P4VP composite were characterised using scanning electron microscopy, transmission electron microscopy, powder X-ray diffraction, Fourier transform infrared spectroscopy, and Raman spectroscopy. …”
    Get full text
    Article
  16. 156
  17. 157

    Lysozyme functionalized zinc-oxide nanoparticles: Synthesis, characterization, and antibacterial assessment against Staphylococcus aureus with futuristic application in wastewater... by Suneeti Singh, Pavni Rekhi, Jewel Mary Saju

    Published 2025-01-01
    “…Since nanoparticle-based biosensors have a higher sensitivity for detecting bacteria than conventional detection techniques, they have become increasingly prevalent. …”
    Get full text
    Article
  18. 158

    Room temperature self-assembly and nonenzymatic electrochemical sensing performance of transition metal-embedded wheel-shaped tungstophosphates by Wen-Da Liu, Hao-Tian Zhu, Xue Zhang, Fang Su, Xiao-Jing Sang, Xiao-Lan Zhang, Lan-Cui Zhang

    Published 2025-03-01
    “…Compared with K28Li5[H7P8W48O184]·92H2O without 3d-TM and most reported POM electrode materials, the proposed 3d-TM-{P8W48} POMs exhibited higher stability and better activity during H2O2 detection. Composite films formed using 1–3 and chitosan (CS) on a glassy carbon electrode exhibited a high sensitivity (1.21 μA∙mmol∙L−1), low detection limit (0.02 mmol∙L−1), and rapid response time (2 s) for H2O2 detection. …”
    Get full text
    Article
  19. 159
  20. 160

    High-Density Arrayed Spectrometer with Microlens Array Grating for Multi-Channel Parallel Spectral Analysis by Fangyuan Zhao, Zhigang Feng, Shuonan Shan

    Published 2025-08-01
    “…In this work, a novel spectrometer architecture based on a microlens array grating (MLAG) is proposed, which addresses the major limitations of conventional spectrometers, including limited parallel detection capability, bulky structures, and insufficient spatial resolution. …”
    Get full text
    Article