-
101
-
102
Sodium cellulose sulfate-derived nitrogen and sulfur co-doped carbon dots for the detection of tetracycline in white shrimp
Published 2025-06-01“…The South American white shrimp, a predominant species in aquaculture, has raised concerns regarding food safety due to the detection of residual tetracycline in both water and shrimp tissues. …”
Get full text
Article -
103
Green Carbon Dots from Pinecones and Pine Bark for Amoxicillin and Tetracycline Detection: A Circular Economy Approach
Published 2025-03-01“…Therefore, a sustainable method for detecting these substances is crucial. Researchers have explored biomass-based carbon dots (CDs) to detect various contaminants, due to their low cost, environmental friendliness, and support of a circular economy. …”
Get full text
Article -
104
Interdigitated Gear-Shaped Screen-Printed Electrode Using G-PANI Ink for Sensitive Electrochemical Detection of Dopamine
Published 2024-12-01“…Dopamine, a neurotransmitter crucial for several body functions, was detected within a linear range of 0.1–100 µM, with a Limit of Detection (LOD) of 0.043 µM (coefficient of determination, R<sup>2</sup> = 0.98) in phosphate-buffer saline (PBS) with ferri/ferrocyanide as the redox probe. …”
Get full text
Article -
105
Nanochannel Electrochemical Sensor Based on Multi-walled Carbon Nanotubes and Gold Nanoparticles for Heavy Metal Detection in Grains
Published 2025-08-01“…This study developed a electrochemical sensor based on gold nanoparticles (AuNPs) and multi-walled carbon nanotubes (MWCNTs) modified anodized aluminum oxide (AAO) membrane, coupled with a screen-printed carbon electrode (SPCE), for trace cadmium (Cd2+) and lead (Pb2+) ion detection in grain samples. The surface morphology and structure of the AuNPs-MWCNTs@AAO membrane were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray diffraction (XRD). …”
Get full text
Article -
106
Effect of Drawing Strain on the Microstructure and Properties of Zn-5Al Coated Steel Wire for Load Detection Cables
Published 2025-03-01“…In order to further develop steel wires with high strength and corrosion resistance for ultra-deep oil well load detection cables,Zn-5Al alloy-coated steel wires were studied.The effects of cold drawing strain on microstructure, mechanical properties and corrosion resistance of coated steel wire were studied by means of scanning electron microscope, X-ray diffraction, electronic universal testing machine,electrochemical workstation and other instruments.Results showed that during the drawing process,the pearlite structure changed from equiaxed to fibrous along the drawing direction, with a gradual decrease in interlamellar spacing and a reduction in coating thickness.When the drawing strain exceeded 2.24, the tensile strength exceeded 2 400 MPa, meeting the requirements for steel wire used in the armoring of 10 000-meter oil well load detection cables.The results of dynamic polarization curves and full immersion tests showed that as the strain increased, the corrosion resistance of the Zn-5Al coated steel wire improved, and the corrosion rate decreased.The neutral salt spray corrosion test indicated that,in terms of long-term corrosion (506 h), the best corrosion resistance was achieved with a strain value of 1.19, where the corrosion rate was 0.104 7 g/(m2∙h).The corrosion products mainly consisted of Zn6 Al2(OH)16 CO3 ∙4H2 O, Zn5(OH)8 Cl2 ∙H2 O, and small amounts of loose ZnO and Zn5(CO3)2(OH)6.After cold drawing deformation, the corrosion products became finer and denser, enhancing their protective effect on the substrate.Cold drawing deformation not only increased the strength of the steel wire but also effectively improved the corrosion resistance of the coated steel wire.…”
Get full text
Article -
107
Development of HfO₂-Based Solar-Blind SAW UV-C Sensor for Corona Discharge Detection Application
Published 2025-01-01“…The feasibility of the sensor for real-world applications was validated through successful testing under simulated corona discharge detection.…”
Get full text
Article -
108
Synthesis of Silver Nanoparticles and Gold Nanoparticles Used as Biosensors for the Detection of Human Serum Albumin-Diagnosed Kidney Disease
Published 2024-10-01“…The modified sensors could detect serum albumin concentrations from 10 to 400 μg/mL, with high correlation values of 0.97 and 0.99 for AgNPs and AuNPs, respectively. …”
Get full text
Article -
109
A Low-Temperature Hydrothermal Synthesis of Prussian Blue Nanocrystal and Its Application in H2O2 Detection
Published 2022-01-01“…This electrode demonstrated a detection limit (1 × 10−7 M) and a linear range starting from the detection limit and extending over 6 orders of magnitude of H2O2 concentrations (1 × 10−7 to 1 × 10−1 M), which was of excellent performance in detecting H2O2.…”
Get full text
Article -
110
Near-Field Transmission-Type Microwave Imaging for Noninvasive Evaluation of Electromagnetic Characteristics: Toward Early Breast Tumor Detection
Published 2017-01-01“…Therefore, the NTMI system is suitable for noninvasive mass screening and has a great potential for applications in early breast cancer detection.…”
Get full text
Article -
111
Detection of caffeic acid in honey using carbon paste electrode modified by copper (II) oxide (CuO) nanoparticles
Published 2025-07-01“…The CuONPs were synthesized via sol-gel method and characterized using field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray (EDX), X-ray diffraction (XRD) and fourier-transform infrared spectroscopy (FT-IR). …”
Get full text
Article -
112
BiVO<sub>4</sub>-Based Photoelectrochemical Sensors for the Detection of Diclofenac: The Role of Doping, Electrolytes and Applied Potentials
Published 2024-11-01“…To evaluate the structural and morphological properties of the coatings, X-ray diffraction analysis (XRD), scanning electron microscopy (SEM), and energy dispersive analysis (EDX) were conducted. …”
Get full text
Article -
113
Tailoring CoFe2O4-modified activated carbon with improved selectivity for electrochemical detection of paracetamol in wastewater
Published 2025-07-01“…The uniqueness of its structure was ascertained by a range of analytical methods, such as transmission electron microscopy, scanning electron microscopy, and powder X-ray diffraction. With a detection limit of 0.027 mM and a limit of quantification of 0.27 mM, the electrochemical characterization by Cyclic voltammetry showed a linear range of PARA from 0.1 mM to 5.0 mM. …”
Get full text
Article -
114
Lutetium Copper@Hexagonal Boron Nitride Nanocomposite Electrode System for Sensing and Signalling Ciprofloxacin
Published 2024-07-01“…The sensor system obtained a wider linear range of (0.05–100 μM) with a lower detection limit value of 0.03 μM and sensitivity 0.7443 μA μM−1 cm−2. …”
Get full text
Article -
115
Retained austenite in multipass high-strength weld metal with a yield strength exceeding 1100 MPa
Published 2025-05-01“…Using transmission Kikuchi diffraction and electron backscatter diffraction, only minor amounts of stand-alone retained austenite were detected. …”
Get full text
Article -
116
ZnO/MO<sub>x</sub> Nanofiber Heterostructures: MO<sub>x</sub> Receptor’s Role in Gas Detection
Published 2025-01-01“…ZnO/MO<sub>x</sub> (M = Fe<sup>III</sup>, Co<sup>II,III</sup>, Ni<sup>II</sup>, Sn<sup>IV</sup>, In<sup>III</sup>, Ga<sup>III</sup>; [M]/([Zn] + [M]) = 15 mol%) nanofiber heterostructures were obtained by co-electrospinning and characterized by X-ray diffraction, scanning electron microscopy and X-ray fluorescence spectroscopy. …”
Get full text
Article -
117
-
118
Multi-Physics Coupling Simulation of Surface Stress Waves for Interface Debonding Detection in Underwater Grouting Jacket Connections with PZT Patches
Published 2025-05-01“…In this paper, an interface debonding defect detection and localization approach for scale underwater GJC specimens using surface wave measurement is proposed and validated numerically. …”
Get full text
Article -
119
Polyaniline/Tungsten Disulfide Composite for Room-Temperature NH<sub>3</sub> Detection with Rapid Response and Low-PPM Sensitivity
Published 2025-06-01“…However, its applicability is limited by its low sensitivity, high detection limits, and long response/recovery times. …”
Get full text
Article -
120
Simultaneous Detection of Bisphenol A and Bisphenol S Migration in Food-Contact Plastics Based on a Dual-ligand Metal-organic Framework
Published 2025-07-01“…The material was characterized by scanning electron microscopy, X-ray diffraction, and Fourier transform infrared spectroscopy. …”
Get full text
Article