-
1001
A mathematical framework for the quantitative analysis of genetic buffering.
Published 2025-06-01“…This analysis reveals the consistent underestimation of double mutant fitness in strains carrying non-interacting query-array pairings (as predicted by the existence of "parallel" relationships between genes). …”
Get full text
Article -
1002
Automated Robotic System for Efficient Solar Panel Dust Removal Using GPS-Based Navigation
Published 2025-01-01“…So dust is removed on the solar panels with the help of robot.This paper describes about the solar panel dust removal using robot which automatically traverse array of solar panels and it also detects the dust and this kind of system efficiently cleans the dust on the solar panels and it also involves many other components which are helpful for the detection of the dust on the solar panels. …”
Get full text
Article -
1003
Development of a Potentiometric Nitrate Ion Microsensor Improved Using Conductive Polymer Doped with Carbon Nanotubes as a Transducing Layer
Published 2024-03-01“…The potentiometric nitrate ion detection is based on the functionalization of the working microelectrode array with a polymer membrane in fluoropolysiloxane (FPSX) containing ionophore tetradodecylammoniumnitrate (TDDAN) and ionic additive potassium tetrakis[3,5-bis(trifuoromethyl)phenyl]borate (KTFPB) to form an all-solid-state ion selective electrode (ISE). …”
Get full text
Article -
1004
Does Price Really Matter for Generic Alternatives? Supervised learning Approaches in Deciding the Right Price for Acceptable Quality Attributes of Amlodipine Besylate among Generic...
Published 2024-04-01“…The quantitation of AMLO and its three sulfonate ester genotoxic impurities of besylate counter ion was settled using a validated high-performance liquid chromatography-diode-array detection method. The classification of correlation between dependent and independent variables was exercised using linear discriminant analysis models. …”
Get full text
Article -
1005
DOA Estimation Method in Multipath Environment for Passive Bistatic Radar
Published 2019-01-01“…Direction-of-arrival (DOA) estimation in multipath environment is an important issue for passive bistatic radar (PBR) using frequency agile phased array VHF radar as illuminator of opportunity. Under such scenario, the main focus of this paper is to cope with the closely spaced uncorrelated and coherent signals in low signal-to-noise ratio and limited snapshots. …”
Get full text
Article -
1006
Lifetime determination of excited states in 104Ru and 130Te via a new Doppler-shift attenuation approach
Published 2025-01-01“…In recent years, several (p,p'γ) experiments have been performed utilizing the combined detector array SONIC@HORUS consisting of 14 HPGe detectors and 12 silicon detectors. …”
Get full text
Article -
1007
Single-Sensor Impact Source Localization Method for Anisotropic Glass Fiber Composite Wind Turbine Blades
Published 2025-07-01“…Experimental results show that the method has a high localization accuracy of 96.9% under single-sensor conditions, which significantly reduces the cost compared to the traditional multi-sensor array scheme. This study provides a cost-effective solution for real-time detection of wind turbine blade impact events.…”
Get full text
Article -
1008
Assessment of greenness, blueness, and whiteness profiles of a validated HPLC-DAD method for quantitation of Donepezil HCl and Curcumin in their laboratory prepared co-formulated n...
Published 2025-01-01“…Optimum seperation was accomplished by utilising Zobrax Eclipse Plus C18 column (4.6*100 mm,5 μm) with gradient elution of the mobile phase composed of 0.02 M phosphate buffer at pH 3.2 and ethanol at flow rate of 1.5 ml/min. A diode array detector (DAD) was implemented for detection at 273 nm and 435 nm for DPZ and CUR, respectively, with the column oven set at 40 °C. …”
Get full text
Article -
1009
Screening of Viral Pathogens from Pediatric Ileal Tissue Samples after Vaccination
Published 2014-01-01“…A broad spectrum, novel DNA detection technology, the Lawrence Livermore Microbial Detection Array (LLMDA), was utilized, and confirmation of viral pathogens using the polymerase chain reaction (PCR) was conducted. …”
Get full text
Article -
1010
Graphene oxide doped polyacrylonitrile-co-maleic acid nanofibers for high-performance liquid chromatography determination of amoxicillin and Oxytetracycline in milk
Published 2025-05-01“…This research focuses on developing a novel sorbent for solid-phase extraction (SPE) of amoxicillin and oxytetracycline from milk and environmental water samples, using electrospun graphene oxide-doped poly(acrylonitrile-co-maleic acid) nanocomposite fibers, followed by high-performance liquid chromatography with diode array detection (HPLC-DAD). The fibers were successfully fabricated and characterized using a suite of techniques: SEM-EDX, FTIR, XRD, BET, XPS, TGA, and Raman spectroscopy. …”
Get full text
Article -
1011
Validation of the method for determination of related impurities in the active antiviral ingredient of enisamium iodide
Published 2018-10-01“…Other materials and reagents were used with sufficient purity (Sigma-Aldrich). Results. Detection limits and limits of quantification for identified and unidentified impurities have been determined. …”
Get full text
Article -
1012
Expanded PCR panel for uropathogen identification and treatment recommendations in urinary tract infections
Published 2025-06-01“…Objectives: To compare the performance of Urine-ID™ test, an expanded multiplex PCR panel designed to detect 26 uropathogens and 49 AMR markers against SUC for pathogen detection in individuals with suspected complicated UTI. …”
Get full text
Article -
1013
Development and validation of stability indicating RP-HPLC method for nebivolol by using the DOE approach
Published 2025-06-01“…The mobile phase comprised acetonitrile and 0.1% perchloric acid in a 55:45 (v/v) ratio, delivered at a flow rate of 1 mL/min. Detection was performed at a wavelength of 282 nm. …”
Get full text
Article -
1014
A Validated RP HPLC-PAD Method for the Determination of Hederacoside C in Ivy-Thyme Cough Syrup
Published 2010-01-01“…A simple reversed phase high-performance liquid chromatographic (RP-HPLC) method coupled with a photodiode array detector (PAD) has been developed and validated for the analysis of hederacoside C, the marker of ivy plant, in Ivy-Thyme cough syrup. …”
Get full text
Article -
1015
Application of double-error correction codes to protect configuration programmable logic memory against space radiation
Published 2023-10-01“…Programmable logic integrated circuits of the field programmable gate array (FPGA) type based on static configuration memory are widely used in the electronics of onboard spacecraft systems. …”
Get full text
Article -
1016
DEVELOPMENT, STANDARDIZATION AND VALIDATION OF ANALYTICAL METHOD FOR QUALITY ASSURANCE AND QUALITY CONTROL OF ALOE-BASED PHARMACEUTICALS AND NUTRACEUTICALS
Published 2020-12-01“…This method is suitable for the detection of major pharmacologically active compounds present in Aloe vera-based pharmaceuticals and nutraceuticals.…”
Get full text
Article -
1017
A rare case of double pituitary prolactinomas: the diagnostic application of intraoperative ultrasonography and DNA methylation markers
Published 2025-01-01“…This case illustrates the translational use of methylation-based liquid biopsy methodologies in detecting and monitoring PTs through the detection of tumor-specific markers in blood specimens. …”
Get full text
Article -
1018
Comprehensive measurement of purines in biological samples
Published 2025-07-01“…The applicability of ultra performance liquid chromatography (UPLC) with photodiode array (PDA) detection for analysis of the most abundant biological relevant purines metabolites is described. …”
Get full text
Article -
1019
The Development and Validation of a High-Performance Liquid Chromatographic Method for the Determination of Urinary Levels of Etoricoxib After Fabric Phase Sorptive Extraction
Published 2025-05-01“…To determine its concentration, fabric phase sorptive extraction (FPSE) was combined with high-performance liquid chromatography and diode array detection (HPLC-DAD). FPSE is a green sample preparation technique that utilizes sol–gel-coated fabric substrates as extraction devices, offering numerous benefits in bioanalysis. …”
Get full text
Article -
1020
Determination of the New Food Ingredient Pyrroloquinoline Quinone Disodium Salt in Foods by Centrifugal Ultrafiltration Coupled with High Performance Liquid Chromatography
Published 2025-04-01“…After purification by centrifugal purification, chromatographic separation was accomplished on a RD-C18 column (4.6 mm × 150 mm, 5 μm) with gradient elution using a mobile phase consisting of tetrabutylammonium bromide-potassium dihydrogen phosphate mixed solution and acetonitrile. Detection was carried out using a photodiode array detector. …”
Get full text
Article