-
901
Study on Distributed Ultrasonic Detection Method of Two-dimensional Gas Temperature Field
Published 2025-05-01“…In the on-site experimental validation within the autoclave, the average relative error between reconstructed temperatures and thermocouple measurements was 4.48%, which indicated the effective performance of the distributed ultrasound temperature measurement system in temperature field reconstruction.ConclusionsThe results demonstrate that the method established in this study for distributed ultrasound detection of two-dimensional gas temperature fields precisely describes the propagation characteristics of ultrasound under thermal/acoustic coupling effects within the autoclave. …”
Get full text
Article -
902
The Role of Visual Information Quantity in Fine Motor Performance
Published 2024-12-01“…Background/Objectives: Fine motor movements are essential for daily activities, such as handwriting, and rely heavily on visual information to enhance motor complexity and minimize errors. Tracing tasks provide an ecological method for studying these movements and investigating sensorimotor processes. …”
Get full text
Article -
903
Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees' residual limb models.
Published 2017-01-01“…Shape percentage maximal error was 2% at the distal end of the residual limb, with intra-rater reliability coefficients presenting the lowest errors (0.2%), both for cross sectional areas and perimeters of the residual limb models.…”
Get full text
Article -
904
Bridge Deflection Separation Prediction Model Based on DWT-LSTM and Its Engineering Application
Published 2025-01-01“…In contrast, the DWT-LSTM deflection separation model achieved the highest accuracy, with root mean square error of only 2.18 mm and mean absolute error of only 2.05 mm. (4) Analysis of the dominant factors influencing noise deflection using the Maximal Information Coefficient (MIC) showed correlation coefficients of 0.35 for temperature and 0.51 for load, indicating that vehicle load has a greater impact on noise deflection than temperature.ConclusionsThis paper presents a DWT-LSTM-based bridge deflection separation prediction model, suitable for predicting long-term deflection variation patterns. …”
Get full text
Article -
905
Robust Data Reconciliation in Supercritical Carbon Dioxide Thermal Systems: From Framework Design to Performance Evaluation
Published 2025-06-01“…A number of studies have been carried out to analyze the theoretical performance of super critical carbon dioxide (S-CO<sub>2</sub>) systems, but monitoring its actual performance when gross errors appear in measurements can be quite challenging. …”
Get full text
Article -
906
Comparative study of the accuracy of CBCT implant site measurements using different software programs
Published 2021-09-01“…All three software programs demonstrated a statistically significant mean absolute measurement error of between 0.43 and 0.56 mm (p-value < 0.01), but no significant difference in error values was found between any of the tested programs (p- value = 0.18). …”
Get full text
Article -
907
Digital Health Technology Interventions for Improving Medication Safety: Systematic Review of Economic Evaluations
Published 2025-02-01“…ConclusionsDHT interventions are economically viable to improve medication safety, with a substantial reduction in ADEs and medication errors. …”
Get full text
Article -
908
Agreement between Placido Disc, Scheimpflug, and Optical Coherence Tomography-Based Measurements of Corneal Topography in Healthy Myopic Individuals
Published 2024-07-01“…Purpose: To evaluate the agreement between topographical and tomographic measurements of the cornea with three methods of Placido-disc, Scheimpflug, and optical coherence tomography in normal eyes with myopic refractive error candidate for keratorefractive surgery. Methods: Subjects within the age range of 18–55 years old candidates for keratorefractive surgery with no history of systemic disorder, eye diseases except refractive errors, and ocular surgery were enrolled in the study. …”
Get full text
Article -
909
Seismic Response Analysis Method of Damping Structures Based on the Inter-history Iteration and Secondary Development of ABAQUS
Published 2025-05-01“…The error rate between the two calculation methods remains within 5%, indicating high accuracy. …”
Get full text
Article -
910
PRECISION, STABILITY ANALYSIS OF THE CRANKSHAFT GRINDING TECHNOLOGICAL PROCESS
Published 2019-01-01“…In addition, the order of processing the number of obtained numerical values and construction of distribution curves is stated for estimating the correspondence between the probability of the experimental distribution and the theoretical distribution.Discussion and conclusions. The implementation of the algorithm for calculating the accuracy and stability for the technological process of grinding the crankshafts during their restoration would reduce the error value. …”
Get full text
Article -
911
Structural stability study of draw-bar for high-speed maglev trains based on the nonlinear analysis method
Published 2022-11-01“…Taking the draw-bar used on the 600 km/h high-speed maglev trains as the research object, this paper explored the impacts of lightweight materials and machining errors on their structural stability with the critical bucking load as the index, according to the stability analysis principle, using the Euler’s formula, the eigenvalue buckling analysis method and the finite element method, and in consideration of the material nonlinear factors and machining errors, and accordingly reveals the influence of the lightweight design of the draw-bar on their structural stability. …”
Get full text
Article -
912
Machine Learning Approach to Identifying Wrong-Site Surgeries Using Centers for Medicare and Medicaid Services Dataset: Development and Validation Study
Published 2025-02-01“… BackgroundWrong-site surgery (WSS) is a critical but preventable medical error, often resulting in severe patient harm and substantial financial costs. …”
Get full text
Article -
913
Dosimetric verification of clinical radiotherapy treatment planning system
Published 2022-01-01“…A statistically significant minor relative error in AAA vs. Acuros XB was found for the bone.…”
Get full text
Article -
914
Comparative evaluation of several toric intraocular lens calculators for predicting postoperative refractive astigmatism in cataract surgery: a real-world study
Published 2025-01-01“…Postoperative refractive astigmatism prediction errors were comprehensively calculated and analyzed using vector analysis. …”
Get full text
Article -
915
Comparison of the Effectiveness of Dialectical Behavior Therapy and Cognitive-Behavioral Therapy on the level of Attention in Girl students with Obsessive-Compulsive Disorder
Published 2025-04-01“…Moreover, it was found that the method of CBT works better than DBT in the case of commission errors, but this result is the opposite in the reaction time.Conclusion: Considering the psychological vulnerability of obsessive-compulsive girls, CBT and DBT packages can be used to improve their psychological level.…”
Get full text
Article -
916
Evaluation of the accuracy of different system torque limiting devices
Published 2025-07-01“…Abstract Background As evaluating the accuracy of friction and spring type mechanical torque limiting devices (MTLDs), no previous study has eliminated eliminated operator-related error. The purpose of this study is to compare and evaluate the accuracy of different types of MTLDs without operator error. …”
Get full text
Article -
917
Perception-action coupling during discriminative interceptive actions
Published 2025-04-01“…Variables representing the spatial aspects of responses, including radial error, gaze error, and the spatial couplings of gaze and hand, however, remained unaffected by task conditions.ConclusionThese findings suggest that decision-making about whether to respond to moving stimuli may impair the temporal accuracy of responses by delaying perception-action coupling without severe influences on the spatial coupling of eye and hand during interceptive actions.…”
Get full text
Article -
918
Studying the effect of keratoconus severity on the accuracy of intraocular lens power calculation using newer keratoconus-specific formulas
Published 2025-04-01“…Results The Kane KC was the only formula to show a myopic mean prediction error (− 0.76 ± 1.06 D). BUII and Barrett True K KC formulas showed the least mean and median absolute errors. …”
Get full text
Article -
919
Gamma scanning technique based on equivalent plane source method in large container
Published 2025-02-01“…Then, γ-scan experiment was simulated for measuring various radioactive source distributions of Co-60 nuclides in large waste containers to verify the accuracy of this method, and the influence law for the nuclide distribution and measurement parameters on the reconstruction results was discovered.ResultsSimulation results demonstrate that a deeper radioactive source location or larger medium density can increase the activity reconstruction error. However, based on the same measurement time, the ITGS measurement error can be controlled within an order of magnitude compared with the conventional TGS.ConclusionThe proposed method achieves higher reconstruction accuracy under complex conditions such as multiple nuclide distributions and high medium density. …”
Get full text
Article -
920
Assessment of dental implant site dimensions in cone beam computed tomography systems
Published 2014-09-01“…Results: The overall mean absolute error was 0.08 mm for Cranex system and 0.5 for Newtom system. …”
Get full text
Article